Loading...
HomeMy WebLinkAboutPD2013-3Weal RO ,l S citta-tuOrAt Cr/ v.k.loan ant \;! LOOM. .2W SIE NON 1 City of Hastings W±E Vs Project Location Utilities Director of Engineering PD -2013-3 Wendell Drive / West 33rd Street From Intersection East on West 33rd for 115' and South on Wendell Drive 150' INDEX OF SHEETS SHEET NO. 1 SHEET NO.2 SHEET NO. 3 SHEET NO.4 SHEET NO. 5 SHEET NO.6 SHEET NO. 7 - 8 TITLE SHEET DETAIL AND NOTES SHEET 33RD STREET PLAN AND PROFILE SHEET 33RD STREET CROSS SECTION SHEET WENDELL DRIVE PLAN AND PROFILE SHEET WENDELL DRIVE CROSS SECTION SHEET EROSION CONTROL DETAILS LEGEND 0 * 0 Spot Elevation Utility Pole Control Point - Nail Set Control Point - Temporary Wood Hub Set Deciduous Tree Coniferous Tree Manhole Fire Hydrant " Water Valve " Gas Valve Date • Light Telephone Box 0 Electrical Junction Box —1912 Contour Line — - - — - - — - - — - - — - - — Property Line CALL BEFORE YOU DIG DIGGERS HOTLINE OF NEBRASKA 1-800-331-5666 Hast'ngs City Surveyor 7 Date SUMMARY OF QUANTITIES ITEM NO. DESCRIPTION ESTIMATED QUANTITIES UNIT 1 Mobilization 2 Saw Cut 3 Remove Header 4 Remove Pavement 5 Build 6" P.C.C. Pavement 47B-3500 6 Build 8" P.C.C. Pavement 47B-3500 7 Build Concrete Header 47B-3500 8 Adjust Manhole to Grade 9 Seeding - Type B NDOR Seed Mixture 10 Furnish & Install 80' x28' C-125 Turf Rein£ Mat 11 Traffic Control Construction and Maintenance NOTES: 1.0 5.0 98.2 70.6 552.0 1512.0 62.0 2.0 0.5 2240.0 1.0 L.S. L.F. L.F. S.Y. S.Y. S.Y. L.F. Each Acres S.F. L.S. The embankment and subgrade shall be adjusted to conform to the lines and grades on the plans in accordance with Section 205 and 302 of the 2007 Standard State Specifications and its supplements. The upper six (6) inches of the subgrade shall be scarified, mixed and recompacted to the following compaction requirements: Percent Density Moisture Minimum Requirements Maximum 95 Min. Opt. -3% Opt. +3% Areas not meeting specified moisture density test requirements shall be removed and recompacted at the Contractor's expense. All subgrade compaction and water necessary for subgrade construction shall not be paid for directly but shall be considered subsidiary to the items of the contract. Excavation, backfilling, and sawing control joints, keyway, tie bars, dowel pins, and rubberized joint sealant shall be considered subsidiary to the unit price per square yard of pavement. DAVID L PACKER F-5390 Hastings City Engineer Date CITY OF HASTINGS, ENGINEERING DEPT. 0 Project Wendell Drive / West 33rd Street = Int. East 115' & South 150' Pro). No. Description PD -2013-3 TITLE SHEET Design By Drawn By Dote B.B. 6/2014 Contractor B.B. MProv�:� Om. No. 1 of 6 x 28+00 T End Project: Sta. 101 +37.86 .L4 SVSS+La elS S6'40+'LZ'BIS a 96'99+9Z'BIS L4 10' 10' 8' 10' 10' 27+00 8' 10' 10' Begin Project: Sta. 99+90.89 O tativamies T 8' 10' 0 O 0 io c io 10' a' < 0 12.33' m N N N io 12.33' r 12.33' 6+00 12.33' x 12.60' 25+00 33rd Street 1 JOINT DETAIL NOTE: 1. Contractor shall protect all survey control points and Property Pins CV from damage. 2. Earthwork on this project shall consist of the street excavation, constructing to the lines LO + and grades as shown on the plans and cross sections, and the disposal of excess excavation on the adjacent Lots and graded. This work shall be subsidiary to the Unit Price of Build 6" & 8" PCC Pavement. Approximately 676 C.Y. of excess excavation will be generated. 4- N All Excess Excavation shall be spread out and compactedon open Lots 13,14, & 15 and grades to blend into existing ground. O All fill in excess of 6" shall be compacted to 90% of standard Proctor density with 0- no less than 5% below optimum moisture. C 3. Contractor shall drop curb at intersection for handicap ramps to be CD m located in field by Engineer. 4. Contractor shall call Diggers Hotline before digging to have all Utilities located. Please note the Utilities crossings that are shown on plans. attttooaaaaaaaay c1°Ca:/p��, aoe6i000e +p_ p DAVID L a®'s zoo WACKER °=� S A et 1.:15.10),1/40 E-5090 e / 4 CITY OF HASTINGS, Y ENGINEERING DEPT. Project Wendell Drive I West 33rd Street = Int. East 115' & South 150' Proj. No. Description PD -2013-3 Detail and Notes Sheet Design By Dote Contractor B.B. 612014 Drown By Approved/y _ , /o / Dr. No. B.B. ':Q�wY71� 2 of 8 1950 be"\,�ej 00 6•�3 056�b v 6b) �)O 0b �g 6C)b4 c6) 6v co\ 6-9 ex `0,1666 -0164 • ,106 w014 V'4 0 1) 0 00 oQC34" °25-c(k0 Lt'6L \'fix b 10 ,-$- 2 Off 4, Shadow Ridge Add. BIk. 6 Lot 1 6 6) ) ) 2.50 TCL-' „ Ox 4b Prop. N=103101.94 ® 0'r m-- E.95074.15 1943.90 Exist. 12' DIP Water Main {{pC 44 5 TC ex 01 w O O?' N C> a N N) N T r 6) 0 4d4 • I C x 43727C - ) `til GCy 5. C> C> ,<3 42.76 FL ) ...G ti'4c6 )x 6) ,11' 4 ,L+4b�"� 40 Cv CON •02 -1 N C) a a 6) N)a /}� N co CD N -r CD CA 70'RO.W. CD io %90' w T r w 0 x a %6£'L w 0) -nr a N rr' %0' L A r r aco m O > W a -1 C) 17' .25 tL 43.61 FL „Co O 3.8 L II N N o cd /C\ x 0 Shadow Ridge Add. BIk. 5 Lot 2 ceoc End Project: Sta. 101 +37.86 Prop/ N=103100.81 r-psoo3.98 e -944.05. ..,.b .45 4 .95 TC FL %L '0 43.99 FL `> ,16 e 43.96 FL )0 4)4b 43.87 FL 43.6d IFL Nx 43.60 FL e ._.._._.J-.-.-\- vC'b5b)°y .0569`' 0 05649)01 '47Vv<0 0005. )Cpl 0 SCALES: 1" = 20' HOR 1" = 2' VER "y •N 04'656), • 6Cv C, Cy60C 4 sy 6)6)0 1b 6)O b N 6� O) 6). 64g1 q<O;q1 X9601 O )1 V 0 V xi a5 16 x�,h •)16 Na )10 )0 )10) 61' ,46,4'),46) q't',t,46) ) „co 414 42.22 F 2,65 T x 1.;i4Nbet 6) 0 43.38 CL 1 titin 0 e;C> b 01 42.76 FL CO 6143:87"CL C CO\ 03 26+,P0 oC 43.25 FL 44.23 CL ,4b)44.47 CL \O 33rd Street 43. 44.57 C 43. 35 � x 4-.45 CL 44.42 6) '4 41).1 `27+0 L 435'9 FL ?)� 6) 7Y 171,16) 43.26 TC 0) `" 41469'17 ' r N RS 00 L=try )4 'dao) b) til ZO'E46L 9'1,1 't7QLS'Let. '� E9'48LEOL=N •dad Furnish & Install 80'x28' C-125 Turf Reinf. Mat Station to Station Side Sq. Ft. 27+42.45 to 27+70.45 LT & RT 2240.0 0 x / SEEDING - Type B NDOR Seed Mixture Station to Station Side Acres 25+55.26 to 29+00 LT & RT 0.5 0 x / NOTE: Seeding quantity calculated from Back of Curb to Property line including intersection returns then from end of pavement to Sta. 29+00 from R.O.W. to R.O.W. 43.75 TC O A b) .44 Vc115'� . TC 6)44.35 T 04 44.45 C N fix, L 03433"CL 44.31 443.96 FL C> 95,'46` 0 43.87 FL 43.64 L FL <3 4**q)* 44.22 � 1 4 . * O. 4 * * * + x* N. 0 * 0.016` * * C> 4,4 44 43.60 FL * 43.24 FL m. vPrO 43.86 CL •43.24 FL 125' 42.i9 FL vPC 0 43.111, CL 23-00 .42.29 FL ) Nx 0. I C' 41 :8 FL 0 42.50 CL 41.88 FL REMOVE CONCRETE HEADER Station to Station Side Lin. Ft. 25+55.26 LT & RT 62.0 0 x / REMOVE PAVEMENT Station to Station Side Sq. Yds. 26+86.45 to 27+22.45 RT 62.0 0 x / BUILD 8" P.C.C. PAVEMENT 47B-3500 Station to Station Side Sq. Yards 25+55.26 to 27+42.45 LT & RT 1512.0 0 x / 1.46 IC 40.98 FL 0 x 6) til 0 0 41.60 CLx 29+00 ��16) 0 40.98 FL 6° %S'0 .49.0 /ice Ia •PA Cx b •0) 1 Shadow Ridge Add. BIk. 3 Lot 3 Prop. N=103182.2 1 O E=95072.74 r' ' C> 1944.12 43./2 FL 44.22 Tr co xtlxib g 43.�654 ¢ � FL Ex. E ` C E6v 43.94 CL Ex`.°' CL Ex,>�� uletry IeteM d10 .4Z'MX 0-0 Sta. 26+86.45 co OT 4444 Sta. 27+22.45 6'0c‘ II Prop. N=1031816 43.63 FL Ex1 E=95002. 2 44.03 TC Ext.' 1943.90 • Ilf a I�It b) ,01 17' IT 43.74 TC 92.5' Lot 3 43.29 TC Ida Nem 42.38 TC N io) 2.94910.33 1942.93 Shadow Ridge 4th Subdivision 41.48 TC Lot 2 co Prop. N=103177.47 1941.97 0:36 I (.; 40.08 FL ADJUST MANHOLE TO GRADE Station Side Each 25+94.19 CL 1.0 0 x / gib. BUILD CONCRETE HEADER J Station to Station Side „soy Lin. Ft. 27+42.45 LT & RT/ 62.0 / • 39.80 I C / 40.58 TC CON 39.30 FL 39.92 CL 0 39:19 C �38.69 FL 39.31 CL 39 0 TC Shadow Ridge 2nd Subdivision Lot 4 \WACKER Li" 39.19 TC CITY OF HASTINGS, ENGINEERING DEPT. C) Project Wendell Drive / West 33rd Street Proj. No. PD -2013-3 Description 33rd Street Construction Plan Design By B.B. Date 5/2014 Contractor B.B. Approved By 3 of 8 1950 1948 1948 1946 1944 1942 1940 01 to 1938 03 600 *10 Ist 0) L- LI 1946 1944 1942 1940 1938 1936 1934 tit ifloj UJ 3 0 1936 1934 1932 0 Tri. CO 2 Tc 0 oi co oi d. ur InC\I tri co co a 44 01 Ca a co 0 01 cki 1932 24+00 4+50 25+00 5+50 26+00 6+50 27+00 7+50 28+00 8+50 29+00 9+50 30+00 70 00:::60 00:::50 00 40 00...30 00 • 20 00 • 10 00 10 00 20 00 . .. 30 00 40 00:::50 00:::60 00 70 00 1950 0 70 00:::60 00:::50 00 40 00...30 00:::20 00 • 10 00 10 00 20 00...30 00 40 00:::50 00:::60 00 70 00 1945 0 Dirt Qu ntities 400. E cavatio 2:::C.V. of:Exce .s :Exca ation 0,'A G:I N:AL:: E SIGN :EL ESIGN E' FILL . ARO AREA RTHWOR A• =0.:00 GINAL :E SIGN: EL ESIGN: E FILL. ARM :AREA :1:944 4944: RTH:WOR A. =0.:00 32:40 950 00 945 00 IGIN AL : E SIGN : E 28+0 L:=1943 -1943: OR GIN:AL::E Oi SIGN' •EL 28+. -194:3 194:3: 940 00 ESIGN E' FILL . AR I AREA RTHWOR A =0.:00 66:41: RTH:WOR A. -0.00 A• 0.00 950 00 945 00 OR G:IN:AL::E =.1.943 90 ESIGN E RTHWOR DESIGN : E' RTHWOR FILL. AR J AREA Project Wendell Drive / West 33rd Street = Int. East 115' & South 150' Proj. No. Description Design By B.B. Drown By B.B. PD -2013-3 West 33rd St. Cross Sections 6/2014 Approved By Contractor SCALES: 1" = 20' HOR 1"=2'VER j9Rprc Jr Et 9Rp`sk'•� 79 •J �re -0 47 4 9A '00 J9 .9 r 'S/s . " S k - .mac_._._. -FED- - - - - - �y �' off'Tp� i " ' 7�TO: J J'VS 0 J9399S <? .9 9AO9R p J_9_RpJ.9�A`,',BS J9A 6+ j9Rp��' °�I,,I ?901/44 R? ',E SR 099p dj. J2 O Ru'TO SS9 rp , I o> W N9RpAA41.3 LEX D 99I 1 J9('9A?28 41.2 'x 9 S02N)s h 'a o w2 tRid ge Add. dd. Blk. 5 41.78 TC 42.28 C Fd 9a R2 O ot J9R 9 ZV+LZ .e i1 S 42.72 TC J Lot 2 F , u e w h �_0)e d PCT0W�UO v o ‘vsto 9'N ' o p 0 101 +00 on azMC)0u, i i LL �Ql V U N v UCO .09 • 0 4 It Of 4 9(< 90C09R7 9AJ9,9J x9 9+00 SA J 0 0 70 JJ7 F f 6fo J9 J 9A0 it 1 0 F J i J9 40'? II L Ex. 418 FL I 9R19A4t t 'VP 4172 CL 9k�IN) JCO 0 0 i 99gya�6 CO .S TJ T Ti OJ JJ 93 99, 99.,,,,,_40.,5,_r'9Fu 9-9 B p��___��nR9/JR >Oe 8d0. J :9 J C Ex. 0 _t- 9 r; N 41.78 F I 42.22 FL I Wendell Drive 42 14 C 1.69% 42.56 CL 42.p 13TC x 3 v g 2.63 FL Jv ' i 4 .29 FL 0 �)I a�R? 41.78 FL J ! CC 9% 42.22 FL .79 TC FJ J 9sr x 9R? ▪ S9 F r? ye 43, 70' 42.28 TC 42.72 TO Exist. 12" DIP Wafer Main c9 j 0 J 7982•9? 9R?>pe? Lot 2 J9 RS lad CL J s J' ?O � 43.94 TC 43.66 TC FJ 43.16 FL 4, .44 FL 9, 2.15%Rs f kt 0tE ftt EE eZff 0 f Ex E 4 4 4 tF4 t 4 Vf t 4 4 f EJ J 7J E 4 f 4 f Nf 9iE 4 f J9 f k J 9 97Rd+ t E f f Ryf t t Rj + lL 1.$' 09 JR+ o 4 4 S'6 \ e hadow adow Ridge �' 4rT� tJJjJ9JJ h RxS tS6S , u�TTo, b ision BIk. 4 k !! iN c E E.4 �4k hOCn44 4 102+00` 4- _Mr �zfaZO() ter J ter J Q4341 CL 4562CL 90 43.22 F69 4352 FL (0 a 79.94' 0 (P a 43.72 TC 44. .a' X (CJ (, J ' J9 J 9 R R.i3 9RRJ Oz vsS O 8 x J (% J J9R 982 9R' ??J Shadow Ridge Add. BIk. 3 Lot 1 LLO NxFJ9%9 AR JLL ; Jfk wWF 0 %S' D.O \ m WLLI LLF-o O94tr6 %9'1 LL 0 01 J x0) J jU M 0r n o om Ct. zW'" x x 0 0 J9 79 AR R� R U U ,J F lo M � 2 J9R o O •9> d 0 Et �U -2 LL ti v %7. 4 J U co %Z ci (o M Ix U i RS Iwo a .09 CO Lot 3 'v' (C,d' i Urn JJ<9 999d. J � si 'JSi> 97.ZZ+LZ WJ9R 79RRTO_R�. .-. _,F. •ip R )6-it.: A�?,919<fic: xOl 3.x9' texO! JX.>svvo*LZ''eel Ss ciE 9R•-•.? 6o' 9 RSu91 99+9Z TIS e - .- AS7fJ�j9 .0. sxS>JO900 J9JRT� NSsA 6.Jq .9 •,.? O9 S?JSn �- Exist. 24" DIP Water Main N ^ / Cn or Q 'i o-2zw- •99 0.44% 61 icp J LL co CV M 0 C" 0 Shadow Ridge Add. BIk. 3 Lot 3 F 79 •RS >6 REMOVE CONCRETE HEADER Station to Station Side Lin. Ft. 100+00 LT & RT 36.2 REMOVE PAVEMENT Station to Station Side Sq. Yds. 99+90.89 to 100+00 LT 8.6 BUILD 6" P.C.C. PAVEMENT 47B-3500 Station to Station Side Sq. Yards 100+00 to 101+37.86 LT & RT 552.0 ADJUST MANHOLE TO GRADE Station Side Each 101+18.54 CL 1.0 SAW CUT Station Side Lin. Ft. 99+90.89 LT 5.0 Inu F�SSIp�•Ar y> D L 1DAVI`1AC CER E-5090 CITY OF HASTINGS, ENGINEERING DEPT. 0 Projec Wendell Drive / West 33rd Street Proj. No. PD -2013-3 Description Wendell Drive Construction Plan Design By B.B. Dote 5/2014 Contractor Drown By B.B. Approved By Dm. No. 5 of 8 1950 1948 V I• STA =.10J+88.86 1950 VRI EL . _ . 1944.42 =•1.5% Oa =•-1:5% CIIRVE 'LEN = 0.00 1948 1946 N 1946 1944 1942 1940 1938 N 1936 N0 +n --I "a n,d Cho ^co 01. CPO. Q)ir %a 1.57 Osn +isr O) op --0.10%. -0.27% r `r1 +lam • Nd- . -.o . .,•j. oU : oor1,- . c or COI °: C) . .N :M....6) U), 0 }) VPI STA. .10.1+57.86 VPI STA _ .102+19.86 1944 1942 1940 VPI EL .1.94196 . • 1 =169% • • VPI 'EL = •1.943.96 92. _..1'.% CURVE. LEN = 0:00 9 92. _ 1.5% 0.10% CURVE - EN 0:00 1938 0 0 m J W 0_ 0 03 1936 1934 1932 1934 O. to d' N 2 T 2. :x dc, 'w 2 'x ........ aW ........ ......... 0-U.... n 0) n 0) O • • o Try N )f X 2 'w 0 CC') CO '- 0)) 0)) 1 oJ•PI I'g Wri ri O N .. n.:4! . . . . . .. ... M OD el W die dm O •,c O 'x 0) CO r r 0 0) 0) 0) 7 7 O ................. W ................. din 2 'X Oti . . . . . . . . 9- w . . . . . . . 1932 98+00 8+50 99+00 9+50 100+00 0+50 101+00 1+50 102+00 2+50 103+00 3+50 104+00 70 00 60 00 50 00 40 00.30 00:::20 00 10 00 U 10 00 20 00 30 00 40 00 50 00 60 00 70 00 70 00:::50 00:::50 00 40 00.30 00 20 00 10 . 00 C 10 00 20 00.30 00 40 00 50 00 60 00 70 00 1 19:5o o_o 950 00 Dirt Qua ntities 290.0 C.Y. o f Excess Excavation 1945 00 1940 00 —3 0 N CO We CR CO ter mit 945•00 940 GO sva =101,+-37.86 OR GIN:AL:EL. =4944.30 ....... DESIGN. :EL =194:4;30 DESIGN EARTHWORK FILL AREA: -0.:00 CU T: AREA:::S:F. . 1950 OD _a50-00 1945 0 945 00 1_940 0_0 940. no :0 err te1+00 OR GINAL :E_ DESIGN EL -1943:95 DESIGN EARTHWORK FILL AREA: -:0.00 •UT • AREA • -75:71-S.F. 19500.0 • : :50: 194502 P• Li! __I 0 62 CO Op 'et CO 0 C‘c N w— h N N 1— CM '—Cl ter "1- 'et tt -I- _950 00 945 00 1 00 -4- 194002 _940 00 :50 STa =1010+-59 OR G:IN:AL: :EL =4942.88 DESIGN. EL -1942:88 DESIGN EARTHWORK FILL.AREA -0..00 UT:AREA -52:13 S F :Q 1945 00 1940 0 0: 19-35 on J 'sr 0 N CO r 0 'et 'Kt —J 0 U. I-- O CO N- 0 0 ..— .a -4- ORIGINAL :E::7.1:941.30 DESIGN: EL DESI-CN EAR-THWORI< FILL. AREA- -0.00 CUT • AREA• =18 S F. . 945 00• _940 GO 9_3_5• no 00: 70 00 60 00 50 00 40 00.30 00 20 00...1.000 U 10.00 20 00.30. 00 40. 00 50 00 60 00...70 00 70 0Q:::60 00 50 00 40 00.30 0Q:::20 00...10. 00 10 00• 20 Q0...30, 00 40 00 ACITY OF HASTINGS, ENGINEERING DEPT. C7,1 0 Project Wendell Drive / West 33rd Street = Int. East 115' & South 150' Proj. No. PD -2013-3 Description Wendell Drive Cross Sections Design By B.B. Dote 6/2014 Contractor Drown By B.B. Approved By Dm. No. 6 of 8 30"(76.2cm) SIM Oat C��rreataWarall1A 4VOitt \\i\ `A%IVA WPO44 WPMParirarrar —Ave 12" (30cm) 2 12" (30cm) r S h Ati 0 attalesabstOtesilaysiffil te. word*. taint, Ohlaigigthilittagfr 0 Sheet 1 of 2. Earth Anchor 4 W W w W W W W Y W W W w w W W W W W W W W W W W W W * W W * y. W W W w W W .y W W W Y' W y. W W W W Y" W * W W W W W W Y' W W W W W w W w w * W W W W w W W W W W W W W Y W W W W W W W w e- W W W W Staples/Stakes Earth Anchor W w * w v.. W W 9.. W W w W W WW W W w ,y W * * W W W W W W * W W W W W W �" W * * W W W W W W W W W W W W W W W W W * W W W W W W y, WW a, W W W W W W .y W W V- W W W W W W W W W W W W W W W W W '- W W W W y '4- A K Drawing Not To Scale NORTH AMERICAN GREEN® 5401 St. Wendel - Cynthiana Rd. PH: 800-772-2040 Poseyville, IN 47633 www.tensarnagreen.com IDrawn on: 01-28-13 SLOPE INSTALLATION EARTH ANCHOR (EA) DETAIL 1. Prepare soil before installing high-performance turf reinforcement mats (HP-TRMs), including any necessary application of lime, fertilizer, and seed. 2. Begin at the top of the slope by anchoring the HP-TRMs in a 12" (30 cm) deep x 12" (30cm) wide trench with approximately 30" (76.2 cm) of HP-TRMs extended beyond the up-slope portion of the trench. Anchor the HP-TRMs with an alternating row of staples and anchors approximately 30" (76.2 cm) apart in the bottom of the trench. Backfill and compact the trench after stapling. Fold remaining 30" (76.2 cm) portion of HP-TRMs back over compacted soil. Secure HP-TRMs over compacted soil with an alternating row of staples/anchors spaced approximately 18" (45 cm) apart across the width of the HP-TRMs. 3. Roll the HP-TRMs (A) down or (B) horizontally across the slope. HP-TRMs will unroll with appropriate side against the soil surface. All HP-TRMs must be securely fastened to soil surface by placing staples/anchors in appropriate locations as shown in the staple pattern guide. 4. The edges of parallel HP-TRMs must be stapled between earth anchors with approximately 4" (10 cm) overlap depending on the HP-TRM type. For curved sections, adjust the overlap edges of parallel HP-TRMs accordingly with a minimum of 4" (10 cm) overlap to accommodate transitional segments. *NOTE: In loose soil conditions, the use of staple or stake lengths greater than 6"(15cm) may be necessary to properly secure the HP-TRMs. ®x44\J� SS/5Z Pe„. pia D/iVIDL 5 m VACX<R tee ° E-5090 a o ®ate% s ; �4I A CITY OF HASTINGS, "�� ENGINEERING DEPT. �/� Project Wendell Drive / West 33rd Street = Int. East 115' & South 150' Proj. No. Description Design By Drown By PD -2013-3 Erosion Control Detail Sheets Date 6/2014 Contractor Approved Dr. No. 7 of 8 A 0.7 Anchors per SQ.YD. (0.8 Anchors per SQ. M.) 2"-5" (5-12.5cm) • 4' (1.2m) C • 2' (0.6m) 3.3' • (•) • 2"_5" 2"-5" (5-12.5cm) (5-12.5cm) „r_ 2"-5" (5-12.5cm) 1.6' *(0.5m) • • 1.7 Anchors per SQ.YD. (2.0 Anchors per SQ. M.) 6' (1.8m) 2"-5" (5-12.5cm) 3' (0.9m) B • 3' (0.9m) T3.3'� 1.6' (lm) (0.5m) T • 3.3' (lm) • • 1.15 Anchors per SQ.YD. (1.35 Anchors per SQ. M.) f -1.6' • D • 21.5'(0.45m) • 3.3' (lm) 2"_5" (5-12.5cm) • • • • • 2.3 Anchors per SQ.YD. (2.7 Anchors per SQ. M.) NOTES: * The performance of ground anchoring devices is highly dependent on numerous site/project specific variables. It is the sole responsibility of the project engineer and/or contractor to select the appropriate anchor type and length. Anchoring shall be selected to hold the mat in intimate contact with the soil subgrade and resist pullout in accordance with the project's design intent. * Anchor Pattern Guide can vary based on earth anchor and blanket selection. * If desired, the system can be soil -filled and sodded after TRM installation. Sod should be staples/staked according to plan specifications. Drawing Not To Scale 2"-5" (5-12.5cm) Tendon Sheet 2 of 2. Load Bearing Plate Anchor Head (Load -Locked Position) Earth Anchor Detail 1:1 4* SVA\ 4r4* ,After 44 r air 4.:V . ate OE 41"0. 44 4G � - 4 ce) ate 04', .. 1 Channel & Shoreline Slopes CRITICAL POINTS A. Overlaps and Seams B. Projected Water Line C. Channel Bottom/Side Slope Vertices \A A f B C� 0 0.1 -40 Shallow Slopes NORTH AMERICAN GREEN® 5401 St. Wendel - Cynthiana Rd. PH: 800-772-2040 Poseyville, IN 47633 www.tensarnagreen.com Disclaimer: The information presented herein is general design information only. For specific applications, consult an independent professional for further design guidance. IDrawn on: 01-28-13 SLOPE INSTALLATION EARTH ANCHOR (EA) DETAIL 1. Prepare soil before installing high-performance turf reinforcement mats (HP-TRMs), including any necessary application of lime, fertilizer, and seed. 2. Begin at the top of the slope by anchoring the HP-TRMs in a 6" (15 cm) deep x 6" (15cm) wide trench with approximately 12" (30 cm) of HP-TRMs extended beyond the up-slope portion of the trench. Anchor the HP-TRMs with a row of staples and anchors approximately 12" (30 cm) apart in the bottom of the trench. Backfill and compact the trench after stapling. Apply seed to compacted soil and fold remaining 12" (30 cm) portion of HP-TRMs back over seed and compacted soil. Secure HP-TRMs over compacted soil with a row of staples/stakes spaced approximately 12" (30 cm) apart across the width of the HP-TRMs. 3. Roll the HP-TRMs (A) down or (B) horizontally across the slope. HP-TRMs will unroll with appropriate side against the soil surface. All HP-TRMs must be securely fastened to soil surface by placing staples/stakes in appropriate locations as shown in the staple pattern guide. 4. The edges of parallel HP-TRMs must be stapled with approximately 2" - 5" (5-12.5cm) overlap depending on the HP-TRM type. 5. Consecutive HP-TRMs spliced down the slope must be end over end (Shingle style) with an approximate 3"(7.5cm) overlap. Staple through overlapped area, approximately 12"(30cm) apart across entire HP-TRM width. *NOTE: In loose soil conditions, the use of staple or stake lengths greater than 6"(15cm) may be necessary to properly secure the HP-TRMs. X00 o DYV:D L oma; C; LR % pin@®°° eft . ACITY OF HASTINGS, (-^'X""1 ENGINEERING DEPT. c/L Project Wendell Drive / West 33rd Street = Int. East 115' & South 150' Proj. No. Description Design By Drawn By PD -2013-3 Erosion Control Detail Sheets Date 6/2014 MProvn/ Contractor Dr. No. 8 of 8 Roadway Design Division M L O JOINT SEALANT FLOW 1" 9„ 8" 1" PREFORMED EXPANSION JOINT FILLER CONCRETE BARRIER CURB QUANTITIES CONCRETE 4.55 CU. YDS./STA. AREA 1.228 SQ. FT. JOINT SEALANT 9„ 1" PREFORMED EXPANSION JOINT FILLER CONCRETE MEDIAN CURB QUANTITIES CONCRETE 4.42 CU. YDS./STA. AREA 1.192 SQ. FT. NOTE: ONE INCH PREFORMED EXPANSION JOINT FILLER SHALL BE PLACED AT INTERVALS OF NOT MORE THAN 100' THRU CONCRETE BARRIER CURB, CONCRETE MEDIAN CURB, AND CONCRETE CURB, TYPE I. 9„ 1" 8" r1" R C ' ♦ s ♦ L G a o p A A A• > • d e A s A' _ p A. D . • NOTE: MAY BE USED WHEN T IS LESS THAN 12" INTEGRAL CONCRETE BARRIER CURB QUANTITIES CONCRETE 1.33 CU. YDS./STA. AREA 0.359 SQ. FT. NO. 4 LONGITUDINAL BAR TO BE GAPPED AT CONTRACTION JOINT LOCATIONS; 3" MIN., 6" MAX. NO. 5 x 8" TIE BARS AT 5'-0" CENTERS NOTE: USE WHEN T IS 12" OR GREATER INTEGRAL CONCRETE BARRIER CURB ALTERNATE TYPE QUANTITIES CONCRETE 1.33 CU. YDS./STA. AREA 0.359 SO. FT. 1'-0" A • A •• A A' ♦ e ♦ zkr INTEGRAL CONCRETE SLOPING CURB QUANTITIES CONCRETE 0.62 CU. YDS./STA. AREA 0.167 SQ. FT. 1'-0" A A • t D ♦ > p. :A • . A p D e . p • INTEGRAL CONCRETE SLOPING CURB QUANTITIES CONCRETE 0.46 CU. YDS./STA. AREA 0.123 SQ. FT. CONTRACTION JOINTS SHALL BE CONSTRUCTED TO MATCH LOCATION OF EXISTING JOINTS EXISTING CONCRETE PAVEMENT JOINT SEALANT FLOW A X, R 1,-0" 11 1" PREFORMED EXPANSION JOINT FILLER FLOW 1,-0" CONCRETE CURB,* TYPE I QUANTITIES CONCRETE 5.22 CU. YDS./STA. AREA 1.408 SQ. FT. NO. 4 LONGITUDINAL BAR TO BE " GAPPED AT CONTRACTION JOINT LOCATIONS; 3" MIN., 6" MAX. R THE AREA BETWEEN CURB AND EXISTING CONCRETE PAVEMENT TO BE CLEANED AND ROUGHENED AS DIRECTED BY THE ENGINEER 3" NO. 5 x 8" TIE BARS AT 5'-0" CENTERS TO BE DRILLED AND GROUTED INTO EXISTING CONCRETE PAVEMENT (WITH APPROVED GROUT) CONCRETE CURB, TYPE II QUANTITIES CONCRETE 0.87 CU. YDS./STA. AREA 0.234 SQ. FT. 9„ e . e ♦ - - p A ♦ .e A' •d' • A p • a EROSION CONTROL CURB QUANTITIES CONCRETE 0.81 CU. YDS./STA. AREA 0.219 SQ. FT. INTEGRAL CONCRETE CURB QUANTITIES CONCRETE 0.89 CU. YDS./STA. AREA 0.239 SQ. FT. No. 4 LONGITUDINAL BAR TO BE GAPPED AT CONTRACTION JOINT LOCATIONS; 3" MIN., 6" MAX. SAW CUT 4" MIN. DEPTH x %" JOINT FILLER RESERVOIR CONTRACTION JOINT THRU CURB NO. 5 x 8" TIE BARS AT 5'-0" CENTERS INTEGRAL CONCRETE CURB ALTERNATE TYPE QUANTITIES CONCRETE 0.87 CU. YDS./STA. AREA 0.234 SQ. FT. NOTE: T = PAVEMENT THICKNESS RIO R9 R8 REV. NO. FEB 09 MAR.05 MAY 01 DATE MULTIPLE REVISIONS MULTIPLE REVISIONS MULTIPLE REVISIONS DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 30 I -R I 0 PAVEMENT DETAILS ORIGINAL: JANUARY 3 I , 1974 DATE Roadway Design Division C M Uo 0 O N a) O^Ow fM 0 V) NOTES: 1" DIA. x 18" DOWEL BARS, T=6" TO 8" 1" DIA. x 18" DOWEL BARS, T OVER 8" EXPANSION TUBE EXISTING SLAB NEW SLAB GREASE DOWELBAR ON EXPANSION TUB SIDE 1" PREFORMED EXPANSION JOINT FILLER JOINT SEALANT DOWEL BARS SHALL BE DRILLED TO A DEPTH OF 8" INTO EXISTING SLAB AND GROUTED. DOWEL BARS SHALL BE PLACED AT 1'-0" CENTERS. THE OUTSIDE DOWEL BAR SHALL BE PLACED 6" FROM THE EDGE OF THE SLAB. THIS JOINT SHALL BE CONSTRUCTED TRANSVERSE TO THE ROADWAY WHERE THE NEW CONCRETE ABUTS THE EXISTING CONCRETE. DOWEL BARS SHALL BE PLACED PARALLEL TO THE ROADWAY € AND TO THE ROADBED. EXPANSION JOINT (SUBSIDIARY) NO. 5 x 18" TIE BARS AT 33" CENTERS TO BE DRILLED AND GROUTED INTO EXISTING SLAB. ASPHALTIC CONCRETE S 1,-0" • • 9'4 s. . • ! n . s. • • EXISTING SLAB -' VARIABLE CONCRETE BASE COURSE W/INTEGRAL CURB EXISTING SLAB NO. 5 x 18" TIE BARS AT 33" CENTERS TO BE DRILLED AND GROUTED INTO EXISTING SLAB. • • e ' s • • a e e e VARIABLE 1,-0" > D > D • • o • ' e • • • s • • • THE FOLLOWING NOTE IS TYPICAL FOR CONCRETE BASE COURSE W/INTEGRAL CURB AND CONCRETE PAVEMENT WIDENING: CONTRACTION AND EXPANSION JOINTS SHALL BE CONSTRUCTED TO MATCH LOCATIONS OF EXISTING JOINTS. CONCRETE PAVEMENT WIDENING ONE INCH PREFORMED EXPANSION JOINT FILLER SHALL BE PLACED ACROSS THE FULL WIDTH OF THE MEDIAN SURFACING AT INTERVALS OF NOT MORE THAN 49'-0'. LONGITUDINAL JOINTS ONE INCH DEEP SHALL BE MADE IN ALL MEDIANS WHEN SURFACING WIDTH IS 16' OR GREATER. TRANSVERSE JOINTS ONE INCH DEEP SHALL BE MADE IN ALL MEDIANS AT INTERVALS OF NOT MORE THAN 8'. TRANSVERSE AND LONGITUDINAL JOINTS SHALL NOT BE FILLED. JOINT SEALANT 3' MIN. SLOPE 2'. i J R . 4 R .: 1" PREFORMED EXPANSION JOINT FILLER JOINT SEALANT L DETAILS OF CONCRETE MEDIAN SURFACING 1" PREFORMED EXPANSION JOINT FILLER 1,-0" 2" v A jti r VARIABLE ONE INCH PREFORMED EXPANSION JOINT FILLER SHALL BE PLACED AT INTERSECTION RETURNS AND WHERE SHOWN ON THE PLANS. TRANSVERSE JOINTS SHALL BE PROVIDED EVERY 8' OR WHERE SHOWN ON THE PLANS. NOTE: RECESS THE EXPANSION JOINT FILLER %" FROM THE TOP SURFACE OF THE CURB TYPE UNDER CONSTRUCTION DETAIL FOR CUTTING EXPANSION JOINT FILLER VARIABLE (2'-0" MIN. TO 3'-6" MAX.) COMBINATION CONCRETE CURB & GUTTER 12" OPENING FOR SIGN POST SIM A 1'-6" 4' MIN. 1" PREFORMED EXPANSION JOINT FILLER W/JOINT SEALANT 12" OPENING FOR SIGN POST B PLAN A 4" MEDIAN SURFACING 1'-6" 4 MIN. JOINT SEALANT zot 1" PREFORMED EXPANSION JOINT FILLER SECTION A -A DETAIL AT END OF MEDIAN ISLAND LENGTH AS SHOWN ON PLANS 8' MIN. FOR 6" CURB 6' MIN. FOR 4" CURB 1" PREFORMED EXPANSION JOINT FILLER W/JOINT SEALANT 4" MEDIAN SURFACING - 4110 - net ar NaNglia 1'-6" II 1" PREFORMED EXPANSION JOINT FILLER A 4' MIN. JOINT SEALANT 1 _C PLAN R_, > D > • > • • • TOP OF SLAB SECTION C -C a a SECTION B -B CONCRETE ISLAND NOSE D CONCRETE PAVEMENT SECTION D -D NOTE: EXISTING CONCRETE PAVEMENT IS TO BE REMOVED IN AREA COVERED BY CONCRETE ISLAND NOSE. DETAILS OF CONCRETE ISLAND NOSE LEFT IN PLACE CONCRETE HEADER NOTE: T = PAVEMENT THICKNESS B RIO R9 R8 REV. NO. FEB 09 MAR.05 MAY 01 DATE MULTIPLE REVISIONS MULTIPLE REVISIONS MULTIPLE REVISIONS DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO.301-RIO P VEMENT DETAILS ORIGINAL: JANUARY 31, 1974 DATE C 0 Roadway Design 1'-0 = - s e s ♦ s s s s s • s • s ♦ A A A • , • A ' O ' , • O INTEGRAL CURB JOINT SEALANT 1" PREFORMED EXPANSION JOINT FILLER DETAILS OF CURB DROPS R BARRIER CURB 5' WALK (4' MIN.) SIF G \. VARIES N • R X 5' 3.00' 10' 4.36' 15' 5.38' 20' 6.24' 25' 7.00' 30' 7.68' 35' 8.31' 40' 8.89' F 1'-0" X R = RADIUS X = (X & R IN FEET) G La CONTRACTION JOINT E #4 REBAR, 4'-0" LONG DRIVEWAY PLAN 2" SLOPING CURB 4' MIN. , e• A • • e • ♦ , , e A e e A ' A ' • A'• • t.tya • e . ♦ ♦A ♦ ♦ ♦ o I SECTION E—E (RURAL DRIVEWAY) 1,_0„ JOINT SEALANT 1" PREFORMED EXPANSION JOINT FILLER SECTION E -E (URBAN DRIVEWAY) JOINT SEALANT 1" PREFORMED EXPANSION JOINT FILLER SECTION F -F (URBAN DRIVEWAY) TOP OF CURB + 0" MINIMUM TRANSITION SIDEWALK TO MEET DRIVE (DISTANCE VARIES) RISE LESS THAN 6" (8% SLOPE) RISE GREATER THAN 6" (5% SLOPE) SLOPE io A A e A s sf2TA' " VARIABLE i SECTION G -G LD R=RISE d-34» ! .s A. .'e. ."e. •"A• M"R s -E ,T s e s s - s s� . s >' e• e -s • , • , 'A • , • A VARIABLE CROSSWALK DRIVEWAY SLOPE TOWARD STREET 2% ryt" p D u .g„ p VARIABLE (3) SIDEWALK 10' DES. (4' MIN.) C M o, LL P o iD O M o o:w 0 0 N (1) 10' MIN. IS REQUIRED WHEN THE EXISTING GRADE IS GREATER THAN 218: (2) 10' MIN. IS REQUIRED WHEN THE EXISTING GRADE IS GREATER THAN t15% (3) 10' MIN. ROUNDING IS REQUIRED WHEN THE EXISTING GRADE IS GREATER THAN +22% 5' SIDEWALK (4' MIN.) (1) PROFILE URBAN DRIVEWAY WITH SIDEWALK (MAXIMUM PERCENT OF GRADE) NOTE: 1" PREFORMED EXPANSION JOINT FILLER SHALL BE PLACED IN ALL SIDEWALKS OR CROSSWALKS AT INTERVALS OF NOT MORE THAN 50'-0", AND AT ALL POINTS WHERE SIDEWALKS OR CROSSWALKS ARE ADJACENT TO CURB. IF SIDEWALK OR CROSSWALK TO BE CONSTRUCTED IS LESS THAN 50'-0" IN LENGTH, ONE SUCH EXPANSION JOINT SHALL BE PLACED AS DIRECTED BY THE ENGINEER. NOTE: T = PAVEMENT THICKNESS RIO FEB 09 MULTIPLE REVISIONS R9 MAR.05 MULTIPLE REVISIONS R8 MAY 01 MULTIPLE REVISIONS REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 30I -RIO PAVEMENT DETAILS ORIGINAL: JANUARY 3 I , 1974 DATE Roadway Design Division co gzra; 0 111 0 Z0-1 ti N 0.- I W M I 0 vCC ° `° C �P U 1D LL Cr; CD0 m cnoW 04 In INAL JOINT ti 0 „ 4 a 3" [ A. MINIMUM OF 5 CHAIRS SPACED AT UNIFORM INTERVALS FOR EACH SPACER BAR a 1'-0 J 1'-0„ s a r a a X \\\\\\'\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ s 1'-0" 1,_0„ 1'-0" a 1'-0„ 1'-0„ J L1 1'_0„ < EXPANSION JOINT FILLER (APPLIES TO EXPANSION JOINTS ONLY) a \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ 1'-0' 1'-0„ s 3" < a L DOWEL BAR HEIGHT AND DIAMETER PAVEMENT THICKNESS (T) MINIMUM BAR DIA. DOWEL BAR HEIGHT (T/2) SKEW TOLERANCE 7 NO. 4 SPACER BARS 11 " T/2 ± V2 a 1'-0 J 1'-0„ s a r a a X \\\\\\'\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ s 1'-0" 1,_0„ 1'-0" a 1'-0„ 1'-0„ J L1 1'_0„ < EXPANSION JOINT FILLER (APPLIES TO EXPANSION JOINTS ONLY) a \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ 1'-0' 1'-0„ s 3" < a L DOWEL BAR HEIGHT AND DIAMETER PAVEMENT THICKNESS (T) MINIMUM BAR DIA. DOWEL BAR HEIGHT (T/2) SKEW TOLERANCE LESS THAN 10" 11 " T/2 ± V2 �A" 10" OR MORE _ 11/2' T/2 ± 1/211 �A" 0 1'-0„ PROFILE GRADE ELEVATION ASSEMBLY PLAN DOWEL BAR LOCATION TABLE L 1 L 2 L 3 #BARS DESCRIPTION 12'-0" 6" 5" 12 12'-0" PAVEMENT 15'-0" 2'-6" 2'-5" 13 15'-0' PAVEMENT (INCLUDES 3'-0" SHOULDER) 16'-0" 3'-6" 3'-5" 13 16°-0" PAVEMENT (INCLUDES 4'-0" SHOULDER) 16'-0" 6" 5" 16 16'-0" RAMP & LOOPS >14'-6" 1'-6" 1'-5" VARIES PAVEMENT WITH CURB >14'-6" 2'-6" 2'-5" VARIES PAVEMENT WITH CURB >6'-0" 6" 5" VARIES IRREGULAR AREAS (WIDEN, FILLETS, GORE ) SLOPE AS SHOWN ON PLANS --� 1" PREFORMED EXPANSION JOINT FILLER SHALL BE USED FOR EXPANSION JOINTS UNLESS OTHERWISE SPECIFIED IN THE PLANS. L1 ti 1'_0„ L3 JOINT SEALANT (HOT POURED) NO. 4 SPACER BAR WELDED DIRECTION OF PLACEMENT NO. 4 SPACER BAR WIRED 12 GAUGE CHAIR SECTION GREASE DOWEL BAR 01( EXPANSION TUBE SIDE ONLY PREFORMED EXPANSION JOINT FILLER (TO BE USED AT EXPANSION JOINTS ONLY) 1„ STOP LUGS 4" END CUT AND BEND EXPANSION TUBE EXPANSION JOINT (SUBSIDIARY) JOINT SEALANT (HOT POURED) ti DOWEL BARS 1" TEMPORARY FILLER GREASE DOWEL BAR ON EXPANSION TUBE SIDE ONLY V ' . M" R. r EXISTING SLAB • t EXPANSION TUBE NEW SLAB NOTES: DOWEL BARS SHALL BE DRILLED TO A DEPTH OF 8" INTO EXISTING SLAB AND GROUTED. SECTION NOTES: THE CONTRACTOR MAY SUBSTITUTE OTHER DESIGNS FOR EXPANSION AND CONTRACTION JOINT SUPPORTS IN LIEU OF THE TYPE SHOWN WITH PRIOR WRITTEN APPROVAL BY THE ENGINEER. DOWEL BARS SHALL BE A MINIMUM OF 17%" IN LENGTH, CENTERED ON JOINTS AND BE SMOOTH BARS. TIE BARS SHALL BE DEFORMED BARS. FOR LOAD TRANSFER DEVICES AT EXPANSION JOINTS IN LANES OTHER THAN THE LANES SHOWN, MAINTAIN THE SPACING OF THE P-6" DOWEL BARS AT P-0" INTERVALS. THE ENDS OF THE NO. 4 SPACER BARS SHALL NOT BE LESS THAN 3" FROM THE EDGES OF THE PAVEMENT OR THE LONGITUDINAL JOINT. THE CONTRACTOR MAY USE A MACHINE FOR PLACING THE LONGITUDINAL TIE BARS IN LIEU OF THE TIE BAR PINS. IF A MECHANICAL TIE BAR PLACEMENT MACHINE IS NOT USED, TIE BAR PINS AS SHOWN SHALL BE USED. TIE, DOWEL & SPACER BARS SHALL CONFORM TO THE REQUIREMENTS OF THE STANDARD SPECIFICATIONS. KEY TYPE LONGITUDINAL JOINTS AND TRANSVERSE CONSTRUCTION JOINTS SHALL BE EDGED WITH %" R. AT TIME OF CONCRETE PLACEMENT. CONCRETE PAVEMENT SHALL BE TINED UNLESS OTHERWISE SHOWN IN THE PLANS. EXPANSION JOINTS SHALL BE INSTALLED AT LOCATIONS SHOWN IN THE PLANS. PAVEMENT PLACED ADJACENT TO R.R. TRACKS REQUIRES 3 -EXPANSION JOINTS SPACED AT APPROX. 49'-6" INTERVALS. EXPANSION JOINTS SHALL NOT BE SKEWED. T= PAVEMENT THICKNESS * THE DEPARTMENT REQUIRES THAT DOWEL BASKETS BE PLACED IN ALL CONTRACTION JOINTS WHICH ARE 6'-0" OR WIDER. THE DOWEL BASKETS SHALL BE PLACED TRANSVERSE TO THE DIRECTION OF THE PREDOMINANT TRAFFIC DIRECTION. R9 JUL II JOINT: EARLY SAW CUT R8 OCT. 10 CHANGED TIMING INFORMATION R7 MAR. 05 MULTIPLE CHANGES REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 329-R9 8 TO 16 INCH CONCRETE PAVEMENT FHWA APPROVED: C O N Roadway Design Di co m 0 0 -o W1nw 0 L1 0 D a 0; 0 O N N o w mow M - N SEE JOINT DETAIL DIRECTION OF PLACEMENT NO. 4 SPACER BARS WELDED 3" MIN. CLEARANCE FROM EDGE OF SLAB A MINIMUM OF 5 CHAIRS PLACED AT UNIFORM INTERVALS SHALL BE USED FOR EACH 12'-0" LANE 54" DIA. SMOOTH BAR MAX. JOINT SEALANT (HOT POURED) CONVENTIONAL SAWING GREASE THIS SIDE ONLY 12 GAUGE CHAIR CONSTRUCTION JOINT 516" TIE BAR COUPLING — DETAILS OF "W" BAR N6" MAX. JOINT SEALANT (HOT POURED) N6" TIE BAR & COUPLING ROTATE BAR IF NECESSARY TO MAINTAIN 2" MIN. CLEARANCE (OPTION 1) KEY TYPE NO. 5 HOOK AND W—BARS AT APPROX. 2'-9" CTRS. OR N6" HOOK AND W—BARS AT APPROX. 2'-9" CTRS. OR JOINT DETAIL THE DOWEL BAR SPACING SHALL BE THE SAME AS SHOWN FOR THE EXPANSION JOINT. REFER TO BAR LOCATION TABLE AND THE DOWEL BAR HEIGHT AND DIAMETER TABLE ON SHEET 1 OF 4. WIDTH AS RECOMMENDED BY THE SAW MANUFACTURER (%" MIN.) JOINT SEALANT `•, (HOT POURED) cc j c) m14„ gzt 1/2 144 144 144 EARLY -SAW CUT SEE JOINT DETAIL 16 GAUGE METAL CONTRACTION JOINT LONGITUDINAL JOINT WITH JOINT SEALANT (HOT POURED) EXISTING SLAB TIE BAR PIN 12 GAUGE METAL PLATE 6" x 6" SQUARE SPOT WELD 30° MAX. 1' SPOT WELD 12 GAUGE METAL PLATE 6" x 6" SQUARE NO. 5 x 1'-6" TIE BARS ON APPROX. 2'-9" CTRS. TO BE DRILLED AND GROUTED INTO EXISTING SLAB TIE BARS ARE TO BE INSTALLED WHERE NEW CONCRETE PAVEMENT IS PLACED ADJACENT TO EXISTING CONCRETE PAVEMENT DETAILS OF TIE BAR NO. 5 x 2'-6" TIE BARS AT APPROX. 2'-9" CTRS. N6" MAX. JOINT SEALANT (HOT POURED) TIE BAR PINS (OPTION 2) KEY TYPE KEY TYPE JOINT SHALL BE USED ON ALL LONGITUDINAL CONSTRUCTION JOINTS WHEN THE ADJACENT LANE IS NOT PLACED AT THE SAME TIME LONGITUDINAL JOINTS NOTE: NO TIE BARS SHALL BE CLOSER THAN 1'-3" TO A TRANSVERSE JOINT. ALL LONGITUDINAL JOINTS BETWEEN LANES AND BETWEEN LANES AND SHOULDERS MUST BE TIED. MEDIAN SHOULD NOT BE TIED. SEE JOINT DETAIL e NEW SLAB NO. 5 x 2'-6" TIE BARS ON APPROX. 2'-9" CTRS. WHEN T=6" TO 10", NO. 6 x 2'-6" TIE BARS ON APPROX. 2'-9" CTRS. WHEN T OVER 10" TIE BAR PINS SAWED WHEN TWO ADJACENT LANES ARE PLACED AT THE SAME TIME, THE LONGITUDINAL JOINT COMMON TO THE LANES SHALL BE SAWED R9 R8 R7 REV. NO 12 GAUGE METAL F N6" CHAIR NOTE: T = PAVEMENT THICKNESS JUL II JOINT: EARLY SAW CUT CHANGED TINING INFORMATION MULTIPLE CHANGES DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 329-R9 8 TO 16 INCH CONCRETE PAVEMENT crviz FHWA APPROVED: 4t,../001// DATE DATE ORIGINAL: OCTOBER 25, 1994 DATE C O_ N 0 Roadway Design LONGITUDINAL JOINTS (IF APPLICABLE) 16'-6" STOP TINING 6" FROM EDGE OF DRIVING LANE SAWED CONTRACTION JOINTS (TYP.) TINING WITH CONCRETE SHOULDER a, 0 in 0 N o 0 03 W M L IX 0 CI 13 O6 -° m "' o mo w 0.1 M O^ N TINING PARALLEL TO LONGITUDINAL JOINT 8" TYP. NOT TINED CENTERED ON JOINT STOP TINING 6" FROM EDGE OF DRIVING LANE INSIDE SHOULDER LONGITUDINAL JOINT (IF APPLICABLE) OUTSIDE SHOULDER DRIVING LANES OUTSIDE SHOULDER TINING LIMITS GORE AREA NOTES: 16'-6" TRANSVERSE JOINT SPACING IS THE STANDARD JOINT SPACING REGARDLESS OF THE PAVEMENT THICKNESS. V VARIES FROM 10'-0" TO MAX. 16'-6". THE LONGITUDINAL JOINT BETWEEN THE SHOULDER AND THE 12'-0" DRIVING LANE IS NOT REQUIRED FOR SHOULDER WIDTHS OF 4'-0" OR LESS. TRANSVERSE JOINTS FOR DOWELED CONCRETE PAVEMENT SHALL BE CONSTRUCTED PERPENDICULAR TO THE ROADWAY. ALL CONCRETE SURFACES, NOT . TINED, WILL REQUIRE TRANSVERSE BROOMING OR BURLAP DRAG. (NOT APPLICABLE TO SHOULDERS) R9 JUL II JOINT: EARLY SAW CUT R8 OCT. /0 CHANGED TINING INFORMATION R7 MAR. 05 MULTIPLE CHANGES REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 329-R9 8 TO 16 INCH CONCRETE PAVEMENT """"` FHWA APPROVED: y� 11 �f�„e, l,Cd csi (tj" J'� �i� n" ' l" zap tri, •. , t4t JAMSHI E 44 S 1 of WO. % DATE 1. silt: ORIGINAL: OCTOBER 25, 1994 4 .,,,,,--- DATE Roadway Design Division N) Q o0 0 LO 0 In N 0-� 0m W.-LLi IX L0 c 0 'O N Ccv Q 0) 0 o v o ow� mpw M -V) CONTRACTION JOINT REQUIRED EVERY 12'-0" WHEN DRIVEWAY LENGTH EXCEEDS 20'-0" DRI VEWA Y 13 iL u 12 0 in 11111 13' 13 MAJOR INTERSECTION V 15' 15' — 15'=15 • 15'15' 15'T 15' COMMERCIAL DRIVEWAY V V V f V V V V V V V V a• • INTERSECTION INTERSECTION N) 12' 12' 14. S INTERSECTION JOINT LAYOUT (TYPICAL INTERSECTIONS WITH RAISED ISLANDS) RURAL URBAN STOP TINING 2'-0" FROM BACK OF CURB INTERSECTION TYP. NO SHOULDER DRIVING LANES DRI VEWA Y NO SHOULDER LONGITUDINAL JOINTS 16'-6" CONC. SHOULDER SAWED CONTRACTION JOINTS (TYP.) DRI VEWA Y STOP TINING 6" FROM EDGE OF DRIVING LANE TINING PARALLEL TO LONGITUDINAL JOINT 8" TYP. NOT TINED CENTERED ON JOINT STOP TINING 6" FROM EDGE OF DRIVING LANE RURAL TINING LIMITS WITH SURFACED SHOULDERS 0 N r N o� ti +--- FOR TRANSITION DETAILS j SEE PLANS um NMI LONGITUDINAL JOINTS STOP TINING 2'-0" FROM BACK OF CURB TINING (TYP.) T 8" TYP. NOT TINED • CENTERED ON JOINT • • • T SAWED CONTRACTION JOINTS (TYP.) V :V--- 5' . 15' 15' T 15'--r— V . V 2'-0" MIN. JOINT LAYOUT (TYPICAL INTERSECTIONS & DRIVES) INTERSECTION ITro N NI S N) STOP TINING 2'-0" FROM BACK OF CURB TINING LIMITS LEGEND NOTES: SAWED CONTRACTION JOINT LONGITUDINAL JOINT 16'-6" TRANSVERSE JOINT SPACING IS THE STANDARD JOINT SPACING REGARDLESS OF THE PAVEMENT THICKNESS. V VARIES FROM 10'-0" TO MAX. 16'-6". VARIABLE SPACING IS USED AROUND INTERSECTIONS AND LARGE DRIVEWAYS WHICH IS TIED TO THE CONCRETE LANES OR SHOULDERS TO MATCH THE JOINTS. ALL CONCRETE SURFACES, NOT TINED, WILL REQUIRE TRANSVERSE BROOMING OR BURLAP DRAG. (NOT APPLICABLE TO SHOULDERS) R9 JUL II JOINT: EARLY SAW CUT R8 OCT. /0 CHANGED TINING INFORMATION R7 MAR. 05 MOLT/PW CHANGES REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 329-R9 8 TO 16 INCH CONCRETE PAVEMENT FHWA APPROVED: ROADWAY DESIGN DIVISION U 0 N 0 0 0 0 L 0 } a 0 U User: dor1301 27 -FEB -2014 07:45 m 0 0 c . 0 a td 0 00 00 0^ rn CHANNELIZATION DEVICES THE FUNCTION OF CHANNELIZATION DEVICES IS TO WARN ROAD USERS OF :CONDITIONS CREATED BY WORK ACTIVITIES IN OR NEAR THE TRAVELED WAY, TO PROTECT WORKERS IN THE TEMPORARY TRAFFIC CONTROL ZONE, AND TO GUIDE DRIVERS AND PEDESTRIANS SAFELY... CHANNELIZING DEVICES INCLUDE BUT ARE NOT LIMITED TO CONES, TUBULAR POSTS, VERTICAL PANELS, DRUMS, BARRICADES, TRAFFIC LANE DIVIDERS, TEMPORARY RAISED ISLANDS, AND BARRIERS. DEVICES USED FOR CHANNELIZATION SHOULD PROVIDE FOR SMOOTH AND GRADUAL TRAFFIC MOVEMENT FROM ONE LANE TO ANOTHER, ONTO A BYPASS OR DETOUR, OR TO REDUCE THE WIDTH OF THE TRAVELED WAY. THEY MAY ALSO BE USED TO SEPARATE TRAFFIC ;FROM THE WORK SPACE, PAVEMENT DROP-OFFS, PEDESTRIAN PATHS, OR OPPOSING DIRECTIONS OF TRAFFIC. CHANNELIZING DEVICES SHALL MEET THE CRASHWORTHY PERFORMANCE CRITERIA CONTAINED IN THE NATIONAL COOPERATIVE HIGHWAY RESEARCH PROGRAM (NCHRP) REPORT 350 OR MANUAL FOR ASSESSING SAFETY HARDWARE (MASH). THEY SHOULD BE CONSTRUCTED AND BALLASTED TO PERFORM IN A PREDICTABLE MANNER WHEN INADVERTENTLY STRUCK BY A :VEHICLE. IF STRUCK, THE DEVICE SHOULD YIELD OR BREAK AWAY, FRAGMENTS OR OTHER DEBRIS FROM THE DEVICE SHOULD NOT PENETRATE THE PASSENGER COMPARTMENT OF THE VEHICLE OR BE A POTENTIAL HAZARD TO WORKERS OR PEDESTRIANS IN THE IMMEDIATE AREA. SPACING OF CHANNELIZING DEVICES SHOULD NOT EXCEED A DISTANCE IN FEET EQUAL TO THE SPEED WHEN USED FOR THE TAPER CHANNELIZATION, AND A DISTANCE IN FEET OF TWICE THE SPEED WHEN USED FOR TANGENT CHANNELIZATION. SPACING OF CHANNELIZATION DEVICES SPEED (MPH) S SPACING OF DEVICES (FEET) TAPER _. TANGENT 25 25 50 35 35 70 45 45 . 90 55 55 110 60 60 120 65 65 130 75 75 150 WARNING LIGHTS MAY BE ADDED TO CHANNELIZING DEVICES IN AREAS WITH FREQUENT FOG, SNOW, OR SEVERE ROADWAY CURVATURE, OR WHERE VISUAL DISTRACTIONS ARE PRESENT, EXCEPT FOR THE SEQUENTIAL FLASHING WARNING LIGHTS, WARNING LIGHTS PLACED ON "CHANNELIZING DEVICES USED IN A SERIES TO CHANNELIZE ROAD USERS SHALL BE STEADY -BURN. . THE RETROREFLECTIVE MATERIAL USED ON CHANNELIZING DEVICES SHALL'. HAVE A SMOOTH, SEALED OUTER SURFACE, MEETING THE REQUIREMENTS OF THE ASTM SPECIFICATION D4956, FOR TYPE IV SHEETING OR TYPE V REBOUNDABLE SHEETING (OR GREATER). COEFFICIENT OF RETROREFLECTION` (CD/LUX/M2) WHITE ORANGE RED YELLOW• 250 100 45 170 THE AMERICAN TRAFFIC SAFETY SERVICES ASSOCIATION (ATSSA) "QUALITY GUIDELINES FOR WORK ZONE TRAFFIC CONTROL DEVICES" SHALL BE USED AS A VISUAL GUIDE FOR DETERMINING IF A TRAFFIC CONTROL DEVICE/OR SIGN IS ACCEPTABLE, MARGINAL OR UNACCEPTABLE. THE NAME AND TELEPHONE NUMBER OF THE AGENCY, CONTRACTOR, OR SUPPLIER MAY BE SHOWN ON THE CHANNELIZING DEVICE BACK OR SUPPORT, BUT NOT ON THE DEVICE FACE. THE LETTERS AND NUMBERS SHALL BE A NON -REFLECTIVE COLOR AND NOT OVER 15 SQUARE INCHES IN TOTAL AREA. PARTICULAR ATTENTION SHOULD BE GIVEN TO MAINTAINING THE CHANNELIZING DEVICES TO KEEP THEM CLEAN, VISIBLE, AND PROPERLY POSITIONED. DEVICES SHALL BE REPLACED THAT ARE DAMAGED AND/OR HAVE LOST A SIGNIFICANT AMOUNT OF THEIR RETROREFLECTIVITY AND EFFECTIVENESS. REFLECTORIZED PLASTIC DRUMS RETROREFLECTIVE WHITE RETROREFLECTIVE WHITE DESIGN RETROREFLECTIVE FLUORESCENT ORANGE OPTIONALtRETROREFLECTIVE FLUORESCENT ORANGE REFLECTORIZED PLASTIC DRUMS USED FOR TRAFFIC WARNING OR CHANNELIZATION SHALL BE CONSTRUCTED OF LIGHTWEIGHT, FLEXIBLE, AND DEFORMABLE MATERIALS AND BE A MINIMUM OF 36 INCHES IN HEIGHT AND HAVE A MINIMUM WIDTH OF AT LEAST A 18 INCHES, REGARDLESS OF ORIENTATION. THE PREDOMINANT COLOR OF THE DRUM SHALL BE ORANGE. METAL DRUMS SHALL NOT BE USED. THE MARKINGS ON DRUMS SHALL BE HORIZONTAL, SHALL BE CIRCUMFERENTIAL, AND SHALL DISPLAY FOUR 6 INCH WIDE BANDS OF RETROREFLECTIVE SHEETING, ALTERNATING FLUORESCENT ORANGE -WHITE -FLUORESCENT ORANGE -WHITE, DRUMS SHALL HAVE CLOSED TOPS THAT WILL NOT ALLOW COLLECTION OF CONSTRUCTION OR OTHER DEBRIS.: APPLICATION DRUMS ARE MOST COMMONLY USED TO CHANNELIZE OR DELINEATE TRAFFIC FLOW BUT MAY ALSO BE USED INDIVIDUALLY OR IN GROUPS TO MARK SPECIFIC LOCATIONS. DRUMS ARE HIGHLY VISIBLE AND HAVE GOOD TARGET VALUE; THEY GIVE THE APPEARANCE OF BEING FORMIDABLE OBSTACLES AND, THEREFORE, COMMAND THE RESPECT OF ROAD USERS. BALLAST SHALL NOT BE PLACED ON TOP OF THE DRUM. DRUMS SHOULD NOT BE WEIGHTED WITH SAND, WATER, OR ANY MATERIAL. BARRICADES BARRICADE TYPE TYPE II TYPE III WIDTH OF RAIL*.8 INCHES MIN. - 12 INCHES MAX. .. 8 INCHES MIN. - 12 INCHES MAX. LENGTH OF RAIL 36 INCHES 8 FEET** WIDTH OF STRIPES 6 INCHES 6 INCHES HEIGHT 36 INCHES 5 FEET REFLECTIVE SHEETING TYPE IV TYPE IV NUMBER OF REFLECTORIZED RAIL FACES 4 (TWO EACH DIRECTION) 6 (THREE EACH DIRECTION) *NOMINAL DIMENSIONS ARE PERMISSIBLE WHEN CONSTRUCTED FROM LUMBER. **WHEN LATERAL SPACE IS LIMITED, SOME TYPE III BARRICADES WITH A 4 FOOT LENGTH OF RAIL, MAY BE ALLOWED WHEN APPROVED BY THE ENGINEER. TYPE III BARRICADE TYPICAL MOUNTING OF FLASHING WARNING LIGHTS. LIGHTS SHALL ALWAYS BE IN VERTICAL ALIGNMENT. TYPE II BARRICADE I+ BALLAST BAR BALLAST TIE CHAIN OR OTHER APPROVED METHOD BALLAST SHALL NOT BE PLACED OVER ANY REFLECTIVE DEVICE DESIGN A BARRICADE IS A PORTABLE OR FIXED DEVICE HAVING TWO OR THREE RAILS WITH APPROPRIATE MARKINGS. IT IS USED TO CONTROL ROAD USERS BY CLOSING, RESTRICTING, OR DELINEATING ALL OR A PORTION OF THE RIGHT-OF-WAY. BARRICADES SHALL BE ONE OF TWO TYPES; TYPE II OR TYPE III. STRIPES ON BARRICADE RAILS SHALL BE ALTERNATING ORANGE AND WHITE RETROREFLECTIVE STRIPES SLOPING DOWNWARD AT AN ANGLE OF 45 DEGREES IN THE DIRECTION ROAD USERS ARE TO PASS. THE STRIPES SHALL BE 6 INCHES WIDE. THE MINIMUM RAIL LENGTH FOR A TYPE II BARRICADE IS 36 INCHES. WHERE BARRICADES EXTEND ENTIRELY ACROSS A ROADWAY, THE STRIPES SHOULD SLOPE DOWNWARD IN THE DIRECTION TOWARD WHICH ROAD USERS MUST TURN. WHERE BOTH RIGHT AND LEFT TURNS ARE PROVIDED, THE STRIPES MAY SLOPE DOWNWARD IN BOTH DIRECTIONS FROM THE CENTER OF THE BARRICADE OR BARRICADES. WHERE NO TURNS ARE INTENDED, THE STRIPES SHOULD SLOPE DOWNWARD TOWARD THE CENTER OF THE BARRICADE OR BARRICADES. BARRICADE RAILS SHOULD BE SUPPORTED IN A MANNER THAT WILL ALLOW THEM TO BE SEEN BY THE ROAD USER, AND IN A MANNER THAT PROVIDES A STABLE SUPPORT THAT IS NOT EASILY BLOWN OVER OR DISPLACED. ON HIGH-SPEED ROADWAYS OR IN OTHER SITUATIONS WHERE BARRICADES MAY BE SUSCEPTIBLE TO OVERTURNING IN THE WIND, SANDBAGS SHOULD BE USED FOR BALLASTING. SANDBAGS MAY BE PLACED ON LOWER PARTS OF THE FRAME OR STAYS TO PROVIDE THE REQUIRED BALLAST BUT SHALL NOT BE PLACED ON TOP OF ANY STRIPED RAIL. BARRICADES SHALL NOT BE BALLASTED BY HEAVY OBJECTS SUCH AS ROCKS OR CHUNKS OF CONCRETE. THE BARRICADE OWNERS NAME, NOT TO EXCEED 15 SQUARE INCHES SHALL BE SHOWN ON THE BARRICADE BACK OR SUPPORT BUT NOT ON ITS FACE. ** WHEN LATERAL SPACE IS LIMITED, SOME TYPE III BARRICADES WITH A 4 FOOT LENGTH OF RAIL, MAY BE ALLOWED WHEN APPROVED BY THE ENGINEER. APPLICATION TYPE II BARRICADES ARE INTENDED FOR USE IN SITUATIONS WHERE TRAFFIC IS MAINTAINED THROUGH THE TEMPORARY TRAFFIC CONTROL ZONE. THEY MAY BE USED INDIVIDUALLY OR IN GROUPS TO MARK A SPECIFIC CONDITION, OR THEY MAY BE USED IN A SERIES FOR CHANNELIZING TRAFFIC. ON THE INTERSTATE, FREEWAY AND EXPRESSWAY SYSTEM, TYPE II BARRICADES SHALL NOT BE USED FOR CHANNELIZATION. TYPE III BARRICADES USED AT A ROAD CLOSURE MAY EXTEND COMPLETELY ACROSS A ROADWAY FROM CURB TO CURB. WHERE PROVISION IS MADE FOR ACCESS OF AUTHORIZED EQUIPMENT AND VEHICLES, THE RESPONSIBILITY FOR THE TYPE III BARRICADES SHOULD BE ASSIGNED TO A PERSON WHO SHALL PROVIDE PROPER CLOSURE AT THE END OF EACH WORK DAY. WHEN A HIGHWAY IS LEGALLY CLOSED BUT ACCESS MUST STILL BE ALLOWED FOR LOCAL TRAFFIC, THE TYPE III BARRICADES MAY NOT BE EXTENDED COMPLETELY ACROSS A ROADWAY. A SIGN WITH THE APPROPRIATE LEGEND CONCERNING PERMISSIBLE USE BY LOCAL TRAFFIC SHALL BE MOUNTED. NORMALLY PERMANENT SIGNS MOUNTED ON BARRICADES SHALL BE ERECTED ABOVE THE BARRICADE. THE SIGNS "ROAD CLOSED", OR "ROAD WORK AHEAD", FOR EXAMPLE CAN EFFECTIVELY BE MOUNTED ABOVE THE BARRICADE THAT CLOSES THE ROADWAY. TYPE III BARRICADES SHALL BE SUPPLEMENTED WITH A LIGHTING DEVICE UNLESS SPECIFICALLY OMITTED BY THE ENGINEER. DETOUR ARROW AND LARGE WARNING ARROW SIGNS SHOULD BE PLACED ON THE FACE OF BARRICADE. CONES RETROREFLECTIVEli WHITE DESIGN CONES SHALL BE PREDOMINANTLY ORANGE, FLOURESCENT RED -ORANGE, OR FLOURESCENT YELLOW/ORANGE, NOT LESS THAN 28 INCHES IN HEIGHT, AND SHALL BE MADE OF A MATERIAL THAT CAN BE STRUCK WITHOUT DAMAGING VEHICLES ON IMPACT. CONES WHEN ALLOWED ON THE INTERSTATE, FREEWAY OR EXPRESSWAY SYSTEM SHALL BE A MINIMUM OF 36 INCHES IN HEIGHT. FOR NIGHTTIME USE, CONES SHALL BE RETROREFLECTIVE OR EQUIPPED WITH LIGHTING DEVICES FOR MAXIMUM .VISIBILITY. RETROREFLECTION OF 28 INCH OR 36 INCH CONES SHALL BE PROVIDED BY A WHITE BAND 6 INCHES WIDE, NO MORE THAN 4 INCHES FROM THE TOP OF THE CONE, AND AN ADDITIONAL 4 INCH WIDE WHITE BAND A MINIMUM OF 2 INCHES BELOW THE 6 INCH BAND. APPLICATION TRAFFIC CONES ARE USED TO CHANNELIZE TRAFFIC, DIVIDE OPPOSING TRAFFIC LANES, DIVIDE TRAFFIC LANES WHEN TWO OR MORE LANES ARE KEPT OPEN IN THE SAME DIRECTION, AND DELINEATE SHORT -DURATION MAINTENANCE AND UTILITY WORK. CONES SHALL NOT BE USED FOR LANE CLOSURE TAPERS OR SHIFTS, CONES SMALLER THAN 42 INCHES SHALL NOT BE USED AT NIGHT ON RURAL HIGHWAYS, UNLESS SHOWN ON THE PLANS OR AS APPROVED OR DIRECTED BY THE ENGINEER. STEPS SHOULD BE TAKEN TO ENSURE THAT CONES WILL NOT BE BLOWN OVER OR DISPLACED BY WIND OR MOVING TRAFFIC. CONES CAN BE DOUBLED UP TO INCREASE THEIR WEIGHT. SOME CONES ARE CONSTRUCTED WITH BASES THAT CAN BE FILLED WITH BALLAST. OTHERS HAVE SPECIAL WEIGHTED BASES. OR WEIGHTS SUCH AS SANDBAG RINGS THAT CAN BE DROPPED OVER THE CONES AND ONTO THE BASE TO PROVIDE ADDED STABILITY. BALLAST, HOWEVER, SHOULD NOT PRESENT A HAZARD IF THE CONES ARE INADVERTENTLY STRUCK. 42 INCH CONES RETROREFLECTIVE FLUORESCENT ORANGE RETROREFLECTIVE WHITE 30 LB BASE 2%/4' MAX. HEIGHT DESIGN 42 INCH CONES SHALL INCLUDE A 30 POUND RUBBER BASE AND DISPLAY FOUR 6 INCH WIDE BANDS OF RETROFEFLECTIVE SHEETING, ALTERNATING FLUORESCENT ORANGE-WHITE- FLOURESCENT ORANGE -WHITE. APPLICATION . WHEN APPROVED BY THE ENGINEER OR SHOWN IN THE PLANS, 42 INCH REFLECTIVE CONES MAY BE USED IN LIEU OF TYPE II BARRICADES OR REFLECTORIZED DRUMS. 42 INCH CONES SHALL NOT BE USED FOR LANE -CLOSURE TAPERS OR SHIFTS. IF A RECTANGULAR BASE IS USED, THE LONG SIDE OF THE BASE SHOULD BE ORIENTED PARALLEL TO THE DIRECTION OF TRAFFIC. TUBULAR POST AND CURB SYSTEM RETROREFLECTIVE BANDS 36" - 42" '1 CURB UNIT 2" 4" DESIGN TUBULAR POSTS USED IN THE SYSTEM SHALL BE 36 INCHES HIGH AND A MINIMUM OF 2 INCHES WIDE WHEN FACING TRAFFIC. THE TUBULAR POST AND CURB SYSTEM SHALL BE MADE OF A MATERIAL THAT CAN BE STRUCK WITHOUT DAMAGING IMPACTING VEHICLES. THE COLOR SHALL BE AS SHOWN IN THE PLANS. THE TUBULAR POSTS SHALL BE RETROREFLECTIVE. RETROREFLECTION OF TUBULAR POSTS SHALL BE PROVIDED BY TWO 3 -INCH WIDE RETROREFLECTIVE BANDS PLACED A MAXIMUM OF 2 INCHES FROM THE TOP WITH A MAXIMUM OF 6 INCHES BETWEEN THE BANDS. EACH CURB SECTION SHALL CONTAIN ONE RETROREFLECTIVE MARKER FACING EACH DIRECTION OF TRAFFIC. THE COLOR OF THE RETROREFLECTIVE BANDS AND MARKERS SHALL MATCH THE POST/CURB COLOR. THE CURB SECTIONS SHALL BE CONFIGURED TO ALLOW FOR DRAINAGE FROM THE PAVEMENT SURFACE. APPLICATION TUBULAR POST AND CURB SYSTEMS MAY BE USED TO DIVIDE OPPOSING LANES OF TRAFFIC OR TO DIVIDE TRAFFIC LANES WHEN TWO OR MORE LANES ARE KEPT OPEN IN THE SAME DIRECTION. FASTENING THE CURBS TO THE PAVEMENT WITH ANCHOR BOLTS OR OTHER SUITABLE METHODS AS DIRECTED BY THE MANUFACTURER IS REQUIRED TO MINIMIZE THE CHANCE OF BEING MOVED BY TRAFFIC. TUBULAR POST AND CURB SYSTEMS SHALL BE INSTALLED IN THE LOCATIONS SHOWN IN THE PLANS OR DIRECTED BY THE ENGINEER. VERTICAL PANELS DESIGN RETROREFLECTIVE MATERIAL ON VERTICAL PANELS SHALL BE 12 INCHES WIDE AND AT LEAST 24 INCHES HIGH. THEY SHALL HAVE ALTERNATING ORANGE AND WHITE STRIPES, WHERE THE HEIGHT OF THE RETROREFLECTIVE MATERIAL ON THE VERTICAL PANEL IS MORE THAN 36 INCHES, A PANEL STRIPE WIDTH OF 6 INCHES SHALL BE USED. WHERE THE HEIGHT OF THE RETROREFLECTIVE MATERIAL ON THE VERTICAL PANEL IS 36 INCHES OR LESS, A PANEL STRIPE WIDTH OF 4 INCHES SHALL BE USED. IF USED FOR TWO-WAY TRAFFIC, BACK-TO-BACK PANELS SHALL BE USED. MARKINGS FOR VERTICAL PANELS SHALL BE ALTERNATING ORANGE AND WHITE RETROREFLECTORIZED STRIPES SLOPING DOWNWARD AT AN ANGLE OF 45 DEGREES IN THE DIRECTION TRAFFIC IS TO PASS. POST MOUNTED VERTICAL PANELS SHALL BE MOUNTED WITH THE BOTTOM A MINIMUM OF 1 FOOT ABOVE THE ROADWAY. VERTICAL PANELS ON A TEMPORARY STAND SHALL BE MOUNTED WITH THE BOTTOM A MAXIMUM OF 1 FOOT ABOVE THE ROADWAY. APPLICATION WHERE SPACE IS LIMITED VERTICAL PANELS MAY BE USED TO CHANNEL TRAFFIC, DIVIDE OPPOSING LANES OF TRAFFIC, DIVIDE TRAFFIC LANES OR REPLACE BARRICADES. WHEN APPROVED BY THE ENGINEER, VERTICAL PANELS MAY BE POST -MOUNTED ALONG THE SIDE OF THE ROADWAY. TUBULAR POSTS DESIGN RETROREFLECTIVE WHITE TUBULAR POSTS SHALL BE PREDOMINANTLY ORANGE, NOT LESS THAN 28 INCHES HIGH, BE A MINIMUM OF 2 INCHES WIDE WHEN FACING TRAFFIC, AND MADE OF A MATERIAL THAT CAN BE STRUCK WITHOUT DAMAGING IMPACTING VEHICLES. TUBULAR POSTS SHALL BE RETROREFLECTIVE. RETROREFLECTION OF TUBULAR POSTS SHALL BE PROVIDED BY TWO 3 INCHES WIDE WHITE BANDS PLACED A MAXIMUM OF 2 INCHES FROM THE TOP, WITH A MAXIMUM OF 6 INCHES BETWEEN THE BANDS. THE BASE SHALL NOT BE WIDER THAN 12 INCHES OR HIGHER THAN 2 INCHES. APPLICATION TUBULAR POSTS HAVE LESS VISIBLE AREA THAN OTHER DEVICES AND SHOULD BE USED ONLY WHERE SPACE RESTRICTIONS DO NOT ALLOW FOR THE USE OF OTHER MORE VISIBLE DEVICES. THEY MAY BE USED EFFECTIVELY TO DIVIDE OPPOSING LANES OF TRAFFIC OR TO DIVIDE TRAFFIC LANES WHEN TWO OR MORE LANES ARE KEPT OPEN IN THE SAME DIRECTION. STEPS SHOULD BE TAKEN TO ASSURE THAT TUBULAR POSTS WILL NOT BE BLOWN OVER OR DISPLACED BY TRAFFIC BY EITHER AFFIXING THEM TO THE PAVEMENT WITH ANCHOR BOLTS OR ADHESIVE, IF A NONCYLINDRICAL DEVICE IS USED, IT SHALL BE ATTACHED TO THE PAVEMENT TO ENSURE THAT THE WIDTH FACING TRAFFIC MEETS THE MINIMUM REQUIREMENTS. TUBULAR POSTS SHOULD NOT BE USED FOR PEDESTRIAN CHANNELIZATION OR A PEDESTRIAN BARRIERS IN TEMPORARY TRAFFIC CONTROL ZONES ON OR ALONG SIDEWALKS. R6 R5 R4 REV. NO. JUN 14 2009 MUTCD UPDATE OCT 98 REVISE CHANNELIZATION DEVICES, TAPER JAN 95 REWRITE DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 920-R6 TRAFFIC CONTROL CONSTRUCTION AND MAINTENANCE ACCEPTED BY FHWA FOR USE ON NATIONAL HIGHWAY SYST DANIEL J. WADDLE E-6289 i JUNE 014 DATE ORIGINAL: OCTOBER 1998 DATE ROADWAY DESIGN DIVISION Computer: DRDESIGN55 0 M L 0 V m Co Date: 26 -FEB -2014 13:21 C rn • to 0 G..u- .. 0 N v w W 2 N OPPOSING TRAFFIC LANE DIVIDERS DESIGN OPPOSING TRAFFIC LANE DIVIDERS SHALL BE A TWO SIDED UPRIGHT RETROREFLECTORIZED ORANGE PANEL, WITH A WIDTH OF 12 INCHES AND A HEIGHT OF 18 INCHES. THE TOP OF THE PANEL SHALL BE 36 INCHES ABOVE THE PAVEMENT. THE SYMBOL ON EACH SIDE SHALL BE TWO OPPOSING BLACK ARROWS. THE LANE DIVIDER SHALL BE MADE OF LIGHTWEIGHT MATERIAL THAT WILL YIELD UPON IMPACT BY A VEHICLE. THE LANE DIVIDER BASE SHALL NOT BE WIDER THAN 12 INCHES OR HIGHER THAN 4 INCHES. THE BASE SHALL BE ATTACHED TO THE EXISTING SURFACE BY EPDXY OR OTHER SUITABLE ADHESIVE, TO ENSURE THAT THE PANEL REMAINS FACING TRAFFIC. APPLICATION OPPOSING TRAFFIC LANE DIVIDERS ARE DELINEATION DEVICES USED AS CENTER LANE DIVIDERS TO SEPARATE OPPOSING TRAFFIC ON A TWO—LANE, TWO—WAY OPERATION. FLAGGERS REQUIRED METHOD EMERGENCY USE ONLY TO STOP TRAFFIC TRAFFIC PROCEED e TO ALERT AND 'es SLOW TRAFFIC ee FLAGGER PADDLE THE STOP/SLOW PADDLE SHALL HAVE AN OCTAGONAL SHAPE ON A RIGID HANDLE. STOP/SLOW PADDLES SHALL BE AT LEAST 18 INCHES WIDE WITH LETTERS AT LEAST 6INCHES HIGH. IF THE STOP/SLOW PADDLE IS PLACED ON A RIGID STAFF, THE MINIMUM LENGTH OF THE STAFF, MEASURED FROM THE BOTTOM OF THE SIGN TO THE END OF THIS STAFF :THAT RESTS ON THE GROUND, SHOULD BE 5 FEET. THE STOP/SLOW PADDLE SHOULD BE THE PRIMARY AND PREFERRED HAND—SIGNALING DEVICE BECAUSE THE STOP/SLOW PADDLE GIVES ROAD USERS MORE POSITIVE GUIDANCE THAN RED FLAGS. USE OF FLAGS SHOULD BE LIMITED TO EMERGENCY SITUATIONS. FLAGGERS A FLAGGER MUST BE DRESSED FOR SAFETY. IN ADDITION TO THE REQUIREMENTS OF THE "WORKER VISIBILITY" SECTION LISTED BELOW, FLAGGERS SHALL WEAR: 1. AN ORANGE OR YELLOW/GREEN CAP OR HARD HAT. 2. A SHIRT WITH SLEEVES, PANTS AND SHOES (TANK TOPS, SHORTS OR SANDALS SHALL NOT BE WORN). FLAGGERS SHALL BE INSTRUCTED IN THE PROPER LOCATION, DUTIES AND; PROCEDURES FOR FLAGGING AS OUTLINED IN THE CURRENT MUTCD AND THE DEPARTMENT OF ROADS FLAGGER'S HANDBOOK. AS REQUIRED BY THE DEPARTMENT OF ROADS, THE FLAGGER SHALL BE CERTIFIED, AND HAVE IN THEIR POSSESSION, A VALID FLAGGER CERTIFICATION CARD. WORKER VISIBILITY ALL WORKERS WITHIN THE RIGHT—OF—WAY WHO ARE EXPOSED EITHER TO TRAFFIC (VEHICLES USING THE HIGHWAY FOR PURPOSES OF TRAVEL) OR TO CONSTRUCTION EQUIPMENT WITHIN THE WORK AREA SHALL WEAR HIGH—VISIBILITY SAFETY APPAREL. HIGH—VISIBILITY SAFETY APPAREL IS DEFINED TO MEAN PERSONAL PROTECTIVE SAFETY CLOTHING THAT; 1. IS INTENDED TO PROVIDE CONSPICUITY DURING BOTH DAYTIME AND NIGHTTIME USAGE, AND 2. MEETS THE PERFORMANCE CLASS 2 OR CLASS 3 REQUIREMENTS; OF THE ANSI/ISEA 107-2004 PUBLICATION ENTITLED "AMERICAN NATIONAL STANDARDS FOR HIGH— VISIBILITY SAFETY APPAREL AND HEADWEAR" LIGHTING DEVICES FUNCTION CONSTRUCTION AND. MAINTENANCE ACTIVITIES OFTEN CREATE CONDITIONS ON OR NEAR THE TRAVELED WAY THAT ARE PARTICULARLY HAZARDOUS AT NIGHT. IT IS OFTEN DESIRABLE AND NECESSARY TO SUPPLEMENT THE REFLECTORIZED SIGNS, BARRIERS, AND CHANNELIZING DEVICES WITH LIGHTING DEVICES. STROBE TYPE LIGHTS ARE NOT PERMITTED. BARRICADE WARNING LIGHTS DESIGN (BATTERY OPERATED) TYPE "A" LOW INTENSITY FLASHING WARNING LIGHTS ARE MOST COMMONLY MOUNTED ON BARRICADES, OR WITH SIGNS AND ARE INTENDED TO WARN THE DRIVER THAT THEY ARE PROCEEDING IN A HAZARDOUS AREA. THESE LIGHTS SHALL NOT BE USED FOR DELINEATION, AS A SERIES OF FLASHING LIGHTS IN A ROW WOULD TEND TO OBSCURE THE DESIRED PATH. TYPE "A" HIGH INTENSITY FLASHING WARNING LIGHTS ARE NORMALLY MOUNTED ON THE TYPE III BARRICADE THAT ACCOMPANIES THE ADVANCE WARNING SIGNS. TYPE "C" STEADY BURN LIGHTS AS USED HEREIN, SHALL MEAN A SERIES OF LOW WATTAGE YELLOW ELECTRIC LIGHTS. WHERE LIGHTS ARE NEEDED TO DELINEATE OR MARK THE TRAVELED WAY THROUGH AND AROUND OBSTRUCTIONS IN A CONSTRUCTION MAINTENANCE AREA, THE DELINEATION SHALL BE ACCOMPLISHED BY USE OF STEADY BURNING LIGHTS. WHEN USED TO SUPPLEMENT CHANNELIZATION, THE MAXIMUM SPACING FOR WARNING LIGHTS SHOULD BE IDENTICAL TO THE CHANNELIZING DEVICE SPACING REQUIREMENTS. WHEN USED TO DELINEATE A CURVE, TYPE "C" WARNING LIGHTS SHOULD ONLY BE USED ON DEVICES ON THE OUTSIDE OF THE CURVE, AND NOT ON THE INSIDE OF THE CURVE. FLASHING ARROW PANEL (DISPLAY) AN ARROW PANEL IS A SIGN WITH A MATRIX OF ELEMENTS, CAPABLE OF EITHER FLASHING OR SEQUENTIAL DISPLAYS. THIS SIGN SHALL PROVIDE ADDITIONAL WARNING AND DIRECTIONAL INFORMATION TO ASSIST IN MERGING AND CONTROLLING ROAD USERS THROUGH OR AROUND A TEMPORARY TRAFFIC CONTROL ZONE. AN ARROW PANEL SHOULD BE USED IN COMBINATION WITH APPROPRIATE SIGNS, CHANNELIZING DEVICES OR OTHER TRAFFIC CONTROL DEVICES. DESIGN . ARROW PANELS SHALL MEET THE SIZE AND SPECIFICATIONS OF THE MUTCD FOR TYPE "C" ARROW DISPLAYS. FLASHING ARROW PANEL SHALL BE RECTANGULAR, OF SOLID APPEARANCE AND FINISHED IN NON—REFLECTIVE BLACK. THE PANEL SHALL BE MOUNTED ON A VEHICLE, TRAILER OR OTHER SUITABLE SUPPORT. MINIMUM MOUNTING HEIGHT MEASURED VERTICALLY FROM THE BOTTOM OF THE PANEL TO THE ROADWAY BELOW IT OR TO THE ELEVATION OF THE NEAR EDGE OF THE ROADWAY. SHALL BE 7 FEET EXCEPT ON VEHICLE—MOUNTED PANELS, WHICH SHOULD BE AS HIGH AS PRACTICAL. THE FOLLOWING SELECTIONS SHALL BE PROVIDED ON THE ARROW PANEL OPERATING MODE PANEL DISPLAY FLASHING ARROW L MINIMUM SHIFTING TAPER • • SHOULDER TAPER RIGHT SHOWN; LEFT OPPOSITE SEQUENTIAL ARROW 100 FEET MAXIMUM 30 ••• • •• • ••C• • • •••• t• • 35 RIGHT SHOWN; LEFT OPPOSITE SEQUENTIAL CHEVRON .245 40 .•• • .••.•• • .••.••.•• 45 RIGHT SHOWN; LEFT OPPOSITE FLASHING DOUBLE ARROW .540 50 •:•• S• 550 600 FLASHING OR ALTERNATING CAUTION 550 605 .660 OR• • • • OR FLASHING FLASHING LINE CORNERS 65 • 715 401 75 ALTERNATING DIAMOND CAUTION THE ARROW PANEL SHALL HAVE A MINIMUM SIZE OF 96 INCHES WIDE AND 48 INCHES HIGH. THE MINIMUM LEGIBILITY DISTANCE SHALL BE 1 MILE. THE PANEL SHALL CONTAIN 25 LAMP ELEMENTS. ARROW PANEL ELEMENTS SHALL BE CAPABLE OF A MINIMUM 50 PERCENT DIMMING, AUTOMATICALLY WHEN AMBIENT LIGHT FALLS BELOW 50 LUX. THE MINIMUM ELEMENT "ON TIME" SHALL BE 50 PERCENT FOR THE FLASHING MODE AND EQUAL INTERVALS OF 25 PERCENT FOR EACH SEQUENTIAL CHEVRON PHASE. THE FLASHING RATE SHALL BE NO FEWER THAN 25 NOR MORE THAN 40 FLASHES PER MINUTE. APPLICATION A FLASHING ARROW OR SEQUENTIAL CHEVRON MODE SHALL ONLY BE USED FOR STATIONARY OR MOVING LANE CLOSURES. FOR SHOULDER WORK BLOCKING THE SHOULDER, FOR ROADSIDE WORK NEAR THE SHOULDER, OR FOR TEMPORARILY CLOSING ONE LANE ON A TWO—LANE, TWO—WAY ROADWAY, AN ARROW PANEL SHALL BE USED ONLY IN THE CAUTION MODE. AN ARROW DISPLAY MODE SHALL NOT BE USED ON A TWO—LANE TWO—WAY ROADWAY FOR TEMPORARY ONE—LANE OPERATION OR LANE SHIFTS. AN ARROW DISPLAY SHALL NOT BE USED TO LATERALLY SHIFT TRAFFIC. TEMPORARY RUMBLE STRIPS EACH SECTION SHALL CONSIST OF 10 SEGMENTS. 6" 24' EDGE OF TRAVELED LANE O r A M tzi M i = 3 1111iiiIISM Q � q N Y ti 11111 IOF ROADWAY 23' DESIGN TEMPORARY RUMBLE STRIPS MAY BE MADE OF ASPHALT PAVING MATERIAL, EPDXY AND AGGREGATE OR OTHER SUITABLE MATERIAL WHICH WILL MAINTAIN A DESIRABLE RUMBLE EFFECT. THE TEMPORARY RUMBLE STRIP SHOULD HAVE AN INSTALLED HEIGHT OF 5/8'. PREFORMED RUMBLE STRIPS MAY BE USED PROVIDED THEY HAVE A MINIMUM 1/2' HEIGHT. TRAFFIC SIGNALS TRAFFIC SIGNALS MAY BE ALLOWED AT CERTAIN EQUIPMENT CROSSINGS WHERE THE VOLUME OF FILL MATERIAL AND THE NUMBER OF EQUIPMENT CROSSINGS PER HOUR IS HIGH. TRAFFIC SIGNALS MAY BE ALLOWED AT CERTAIN BRIDGE CONSTRUCTION SITES WHERE A COMBINATION OF ONE—WAY TRAFFIC AND HIGH TRAFFIC VOLUMES WOULD BE BEST SERVED WITH THIS TYPE OF TRAFFIC CONTROL. ALL TRAFFIC SIGNAL REQUESTS AND METHOD OF INSTALLATION ON THE STATE HIGHWAY SYSTEM SHALL BE IN COMPLIANCE WITH THE MUTCD AND MUST BE APPROVED BY THE STATE TRAFFIC ENGINEER. IF, AFTER THE SIGNAL ASSEMBLIES ARE ERECTED AND THE ROAD IS OPEN TO PUBLIC TRAVEL, THE SIGNAL SYSTEM IS NOT PUT IMMEDIATELY INTO OPERATION, THE SIGNAL FACES SHALL BE COVERED WITH BURLAP OR OTHER OPAQUE MATERIAL SUBJECT TO THE APPROVAL OF THE ENGINEER, INOPERATIVE SIGNALS ON ROADS OPEN TO THE PUBLIC SHALL ALWAYS BE COVERED. TILTING THE SIGNALS UPWARD IS NOT AN ACCEPTABLE ALTERNATIVE TO COVERING THE HEADS. FLOODLIGHTS WHEN NIGHTTIME WORK IS REQUIRED, FLOODLIGHTS SHALL BE USED TO'ILLUMINATE FLAGGER STATIONS. FLOODLIGHTS SHOULD BE USED TO ILLUMINATE EQUIPMENT CROSSINGS, AND OTHER AREAS WHERE EXISTING LIGHT IS NOT ADEQUATE FOR THE WORK TO BE PERFORMED SAFELY. IN NO CASE SHALL FLOODLIGHTING BE PERMITTED TO CREATE A DISABLING GLARE FOR DRIVERS. THE ADEQUACY OF THE FLOODLIGHT PLACEMENT AND ELIMINATION OF POTENTIAL GLARE SHOULD BE CHECKED BY DRIVING THROUGH THE PROJECT. PAVEMENT MARKING IT IS INTENDED TO THE EXTENT POSSIBLE, THAT MOTORISTS BE PROVIDED MARKINGS WITHIN A WORK AREA COMPARABLE TO THE MARKINGS NORMALLY MAINTAINED ALONG ADJACENT ROADWAYS, PARTICULARLY AT EITHER END OF THE WORK AREA. ALL MARKINGS AND DEVICES USED TO DELINEATE VEHICLE AND PEDESTRIAN PATHS SHALL BE CAREFULLY REVIEWED DURING DAYTIME AND NIGHTTIME PERIODS TO AVOID INADVERTENTLY LEADING DRIVERS OR PEDESTRIANS FROM THE INTENDED PATH. PAVEMENT MARKINGS NO LONGER APPLICABLE SHALL BE REMOVED UNLESS OTHERWISE APPROVED BY THE ENGINEER. TAPERS TAPERS ARE CREATED USING A SERIES OF CHANNELIZING DEVICES OR PAVEMENT MARKINGS TO MOVE TRAFFIC OUT OF OR INTO ITS NORMAL PATH. MERGING TAPER A MERGING TAPER REQUIRES THE LONGEST DISTANCE BECAUSE DRIVERS ARE REQUIRED TO MERGE INTO COMMON ROAD SPACE. THE TAPER SHOULD BE LONG ENOUGH TO ENABLE MERGING DRIVERS TO HAVE ADEQUATE ADVANCE WARNING AND SUFFICIENT LENGTH TO ADJUST THEIR SPEEDS AND MERGE INTO A SINGLE LANE BEFORE THE DOWNSTREAM END OF THE TRANSITION. SHIFTING TAPER A SHIFTING TAPER IS USED WHEN MERGING IS NOT REQUIRED, BUT A LATERAL SHIFT IS NEEDED. APPROXIMATELY ONE—HALF "L" HAS BEEN FOUND TO BE ADEQUATE. WHERE MORE SPACE IS AVAILABLE, IT MAY BE BENEFICIAL TO USE LONGER TAPERS. GUIDANCE FOR CHANGES IN ALIGNMENT MAY ALSO BE ACCOMPLISHED BY USING HORIZONTAL CURVES DESIGNED FOR NORMAL HIGHWAY SPEEDS. SHOULDER TAPERS A SHOULDER TAPER MAY BE BENEFICIAL ON HIGH—SPEED ROADWAYS WHERE SHOULDERS ARE PART OF THE ACTIVITY AREA AND ARE CLOSED, OR WHEN IMPROVED SHOULDERS MIGHT BE MISTAKEN AS A DRIVING LANE IN THESE INSTANCES, THE SAME TYPE, BUT ABBREVIATED, CLOSURE PROCEDURES USED ON A NORMAL PORTION OF THE ROADWAY CAN BE USED. IF USED, SHOULDER TAPERS APPROACHING THE ACTIVITY AREA SHOULD HAVE A LENGTH OF ABOUT ONE—THIRD "L". DOWNSTREAM TAPERS THE DOWNSTREAM TAPER MAY BE USEFUL IN TERMINATION AREAS TO PROVIDE A VISUAL CUE TO THE DRIVER THAT ACCESS IS AVAILABLE TO THE ORIGINAL LANE OR PATH THAT WAS CLOSED. WHEN USED, IT SHOULD HAVE A MINIMUM LENGTH OF ABOUT 100 FEET PER LANE, WITH DEVICES SPACED ABOUT 20 FEET APART. ONE LANE, TWO WAY TAPER THE ONE—LANE, TWO—WAY TAPER IS USED IN ADVANCE OF AN ACTIVITY AREA THAT OCCUPIES PART OF A TWO—WAY ROADWAY IN SUCH A WAY THAT A PORTION OF THE ROAD IS USED ALTERNATELY BY TRAFFIC IN EACH DIRECTION. A SHORT TAPER HAVING A MINIMUM LENGTH OF 50 FEET AND A MAXIMUM LENGTH OF 100 FEET WITH CHANNELZING DEVICES AT APPROXIMATELY 20 FOOT SPACINGS SHOULD BE USED TO GUIDE TRAFFIC INTO THE ONE—LANE—SECTION AND A DOWNSTREAM TAPER WITH A LENGTH OF APPROXIMATELY 100 FEET SHOULD BE USED TO GUIDE TRAFFIC BACK INTO THEIR ORIGINAL LANE. TAPER LENGTH CRITERIA FOR TEMPORARY TRAFFIC CONTROL ZONES TYPE OF TAPER TAPER LENGTH (FEET) MERGING TAPER L MINIMUM SHIFTING TAPER 1/2 L MINIMUM SHOULDER TAPER 1/3 L MINIMUM TWO—WAY TAPER 100 FEET MAXIMUM FORMULAS FOR L SPEED FORMULA 40 MPH OR LESS —W52 L 60 45 MPH OR GREATER L = WS L = TAPER LENGTH IN FEET W = WIDTH OF OFFSET IN FEET S = POSTED SPEED LIMIT PRIOR TO WORK IN MPH TAPER LENGTH L (FEET) SPEED (MPH) LANE WIDTH S 10 FT. 11 FT. 12 FT. 25 105 115 ':125 30 150 165 .180 35 205 225 .245 40 270 295 ,320 45 450 495 .540 50 500 550 600 55 550 605 .660 60 600 660 720 65 650 715 780 75 750 825 900 R6 R5 R4 REV. NO. JUN 14 OCT 98 JAN 95 DATE 2009 MUTCD UPDATE REVISE CHANNELIZATION DEVICES, TAPER REWRITE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 920-R6 TRAFFIC CONTROL CONSTRUCTION AND MAINTENANCE ACCEPTED BY FHWA FOR USE 0 NATIONAL HIGHWAY SYSTE i o . DANIEL J. orti 141 a WADDLE I. E-6289 N * OF < JUNE 2S 4 DATE ORIGINAL: OCTOBER 1998 DATE ROADWAY DESIGN DIVISION r -- ES 0 M i 0 v i- 0 N N M v 0 0 W U- N a) 0 0 C rn 0 0 0 00 N "M �0 my ro i.i U) i— lei W 2 0 ROADSIDE SIGNS HEIGHT AND LATERAL LOCATION OF SIGNS RURAL AREA PAVED SHOULDER URBAN AREA TYPICAL FIRST SIGN AT CONSTRUCTION SITE WITH TYPE "A" FLASHING WARNING LIGHT MOUNTED ABOVE TYPE III BARRICADE WITH SPEED ADVISORY PLATE ROAD CLOSED 500 FT PORTABLE AND TEMPORARY MOUNTING TYPICAL SIGN MOUNTINGS POST MOUNTED SIGNS 48 INCHES OR WIDER REQUIRE TWO POSTS SIGN WIDTHS LESS THAN48 INCHES MAY BE MOUNTED WITH -ONE POST TYPICAL SIGN MOUNTINGS OTHER THAN POST MOUNTED TYPE III BARRICADE WITH SIGN ROAD CLOSED `": DETOUR111.116.11.11.11.111 TYPE III BARRICADE WITH SIGN AND DETOUR ARROW TYPE II BARRICADE WITH DETOUR ARROW OR SIGN MIN. 1 FT. ABOVE PAVEMENT 1500 FTI PORTABLE AND TEMPORARY MOUNTING TYPE III BARRICADE WITH CHEVRONS PLASTIC DRUM WITH CHEVRON OR SIGN TEMPORARY SIGN SUPPORTS ALL "TEMPORARY SIGN" SUPPORTS (BASES) SHALL BE NCHRP 350 OR MASH (TL -3) APPROVED. "TEMPORARY SIGNS" ARE ALL TEMPORARILY MOUNTED WORK ZONE SIGNS THAT ARE NOT POST MOUNTED IN THE GROUND AT THE TYPICAL 5 FOOT MOUNTING HEIGHT. TEMPORARY SIGNS ARE CONSIDERED NCHRP 350 OR MASH CATEGORY 2 DEVICES AND ARE MOUNTED ON TEMPORARY SIGN STANDS. TEMPORARY SIGNS SHALL BE MOUNTED A MINIMUM OF 1 FOOT ABOVE THE GROUND, UNLESS OTHERWISE REQUIRED TO BE MOUNTED AT A HIGHER HEIGHT. TEMPORARY SIGNS AND THEIR SUPPORTS SHALL NOT BE IN PLACE LONGER THAN 3 DAYS. ANY SIGN THAT IS TO BE IN PLACE LONGER THAN 3 DAYS SHALL BE POST MOUNTED OR MOUNTED TO A DRUM, BARRICADE, OR BARRIER, AS REQUIRED BY THE PLANS OR SPECIFICATIONS. PORTABLE DYNAMIC MESSAGE SIGN DELINEATION 0 �--� PDMS 0 0 IN MEDIAN 3'-0" MIN. J M --OUTSIDE CLEAR ZONE ON SHOULDER OFF SHOULDER PORTABLE DYNAMIC MESSAGE SIGNS (PDMS) THE PLACEMENT OF PDMS SHOULD BE IN THE FOLLOWING ORDER: WHENEVER POSSIBLE, PDMS SHOULD BE PLACED OFF OF ANY USABLE PORTION OF THE ROADWAY ON THE RIGHT SIDE OF THE ROADWAY. WHEN PLACED OUTSIDE THE CLEAR ZONE OR BEHIND GUARDRAIL OR CONCRETE PROTECTION BARRIERS, DELINEATION IS NOT REQUIRED. WHERE FIELD CONDITIONS DO NOT ALLOW FOR THIS PLACEMENT, THE SIGNS MAY BE LOCATED ON THE OUTSIDE SHOULDER OF THE ROADWAY OR WITHIN THE MEDIAN. A. A MINIMUM CLEARANCE OF 3 FEET MEASURED HORIZONTALLY FROM THE EDGE OF THE SIGN TO THE EDGE OF THE TRAVELED WAY IS RECOMMENDED. B. THE PDMS SHOULD HAVE A MINIMUM MOUNTED HEIGHT OF 7 FEET ON FREEWAYS, EXPRESSWAYS AND IN URBAN AREAS. C. ALL OTHER RURAL APPLICATIONS SHOULD HAVE A MINIMUM HEIGHT OF 5 FEET. THESE HEIGHTS ARE MEASURED VERTICALLY FROM THE BOTTOM OF THE SIGN TO THE ELEVATION OF THE NEAR EDGE OF THE PAVEMENT. REFLECTORIZED PLASTIC DRUMS SHOULD BE USED TO DELINEATE EACH SIGN USING A 1/3 L TAPER. THESE DRUMS SHOULD BE POSITIONED ON THE UPSTREAM END OF THE SIGN TO FORM A TAPER LEADING UP TO THE TRAFFIC SIDE OF THE SIGN. FOR A SIGN LOCATED IN THE MEDIAN, THE SIGN SHOULD BE DELINEATED WITH A 42 INCH CONE ON ALL FOUR CORNERS. WHEN DEPLOYED, THE SIGN SHALL BE SIGHTED AND ALIGNED WITH APPROACHING TRAFFIC TO ENSURE VISIBILITY OF THE MESSAGE. IF MULTIPLE SIGNS ARE USED, THE SIGNS SHOULD BE LOCATED ON THE SAME SIDE OF THE ROAD AND SEPARATED ACCORDING TO PROPER SIGN SPACING. WHEN PRACTICAL, PDMS SHOULD NOT BE USED TO REPLACE STATIC SIGNS FOR LONG TERM USAGE (OVER 10 DAYS). WHEN PDMS ARE TO BE DEPLOYED FOR LONG PERIODS, SUCH AS INCIDENT MANAGEMENT ROLES, CONCRETE PADS WITH APPROPRIATE TIE DOWNS SHOULD BE CONSTRUCTED FOR THEIR PLACEMENT. PDMS NOT ACTIVELY BEING USED IN A CONSTRUCTION OR INCIDENT MANAGEMENT ROLE SHOULD BE REMOVED. REFER TO NDOR "DMS GUIDELINES" FOR PROPER PDMS MESSAGE INFORMATION. NOTES 1. ALL TRAFFIC CONTROL DEVICES SHALL MEET THE APPLICABLE STANDARDS AND SPECIFICATIONS PRESCRIBED IN PART 6 OF THE LATEST ADOPTED EDITION OF THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, (MUTCD)" AND THE STATE OF NEBRASKA SUPPLEMENT TO THE MUTCD. ALL TRAFFIC CONTROL DEVICES SHALL BE CRASHWORTHY AND QUALIFY AS SUCH ACCORDING TO THE TESTING AND ACCEPTANCE GUIDELINES OF THE NATIONAL COOPERATIVE HIGHWAY RESEARCH PROGRAM (NCHRP) REPORT 350 OR MANUAL FOR ASSESSING SAFETY HARDWARE (MASH). 2. TRAFFIC CONTROL PLANS AND DEVICES SHOULD FOLLOW THE PRINCIPLES SET FORTH, BUT MAY DEVIATE FROM THE TYPICAL DRAWINGS TO ALLOW FOR CONDITIONS AND REQUIREMENTS OF THE PROJECT. 3. TRAFFIC CONTROL DEVICES SHALL BE INSTALLED SO AS NOT TO OBSTRUCT THE VIEW OF OTHER TRAFFIC CONTROL DEVICES. 4. THE ENGINEER SHALL HAVE THE AUTHORITY TO REQUIRE THE USE, AND APPROVE THE LOCATION OF ANY OF THE DEVICES SHOWN IN THESE PLANS. WORK ZONE SPEED LIMIT NOTES A. WORK ZONE SPEED LIMITS SHALL NOT BE INSTALLED WITHOUT A SPEED ZONE AUTHORIZATION COMPLETED BY THE DEPARTMENT. B. REDUCED SPEED LIMITS SHOULD BE USED ONLY IN THE SPECIFIC PORTION OF THE WORK ZONE WHERE CONDITIONS OR RESTRICTIVE FEATURES ARE PRESENT. HOWEVER. FREQUENT CHANGES IN THE SPEED LIMIT SHOULD BE AVOIDED. THE REDUCTION OF SPEED SHOULD BE DESIGNED SO VEHICLES CAN SAFELY TRAVEL THROUGH THE WORK ZONE WITH A SPEED LIMIT REDUCTION OF NO MORE THAN 10 MPH UNLESS OTHERWISE NOTED IN THE PLANS. C. WORK ZONE SPEED LIMITS SHOWN ARE TYPICAL APPLICATIONS ONLY AND ARE NOT TO BE ASSUMED AS THE SPEED LIMITS REQUIRED FOR THE WORK. D. EXISTING SPEED LIMIT SIGNS SHALL BE REMOVED OR COVERED WHEN A REDUCED WORK ZONE SPEED LIMIT IS IN EFFECT IN THE SAME AREA. E. WORK ZONE SPEED LIMIT SIGNS SHALL BE INSTALLED EVERY MILE THROUGH THE WORK AREA WHEN SPEED ZONE IS REDUCED. F. A SPEED LIMIT SIGN ENDING THE REDUCED SPEED ZONE SHALL BE INSTALLED AT THE END OF EACH ZONE. G. DOUBLE FINES AND REDUCED SPEED ZONE SIGNING ARE NOT REQUIRED FOR SHORT -DURATION WORK LESS THAN 12 HOURS. TAPER FORMULA L = S x W FOR SPEEDS OF 45 MPH OR MORE. L = 6 2 FOR SPEEDS OF 40 MPH OR LESS. WHERE: L = MINIMUM LENGTH OF TAPER. S = NUMERICAL VALUE OF POSTED SPEED LIMIT PRIOR TO WORK. W =WIDTH OF OFFSET (LANE WIDTH). LEGEND C::= TYPE III BARRICADE • 0 REFLECTORIZED PLASTIC DRUM REFLECTORIZED PLASTIC DRUM. OR 42" CONE PORTABLE DYNAMIC MESSAGE SIGN R6 JUN 14 R5 OCT 98 R9 JAN 95 REV. NO. DATE 2009 MUTCD UPDATE REVISE CHANNELIZATION DEVICES, TAPER REWRITE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 920-R6 TRAFFIC CONTROL CONSTRUCTION AND MAINTENANCE ACCEPTED BY FHWA FOR USE 0 NATIONAL HIGHWAY SYSTEM° DANIEL J. WADDLE E-6289 JUNE 20 4 DATE ORIGINAL: OCTOBER 1998 DATE ROADWAY DESIGN DIVISION In U, z U) w 0 0 cc L a) a 0 .0 N 0 M L 0 .0 L 0 y 27 -FEB -2014 08:25 3 0 mo 00 N .au - gio055 a)o 0 _ U� LL N LU w w s CROSS ROAD INTERSECTING CLOSED ROAD ii/"i"/ /' ii CLOSED i i i i i i i //////// // ////' i ROAD, ," /iii//i/ ROAD CLOSED R11-2-48 W/TYPE A WARNING LIGHT MOUNTED ABOVE TYPE III BARRICADE ADDITIONAL TYPE III BARRICADES MAY BE USED AS NEEDED 1 W20 -3A-48 ROAD CLOSED 1 MILES AHEAD LOCAL TRAFFIC ONLY R11 -3A-60 TRAFFIC NOT ALLOWED TO CROSS CLOSED ROAD ROAD CLOSED PLASTIC DRUMS AS ;`NEEDED TO DELINEATE .OPEN TRAVEL AREA OR ROAD CLOSED TO THRU TRAFFIC R11-2-48 R1t-4-60 W/TYPE A WARNING LIGHT MOUNTED ABOVE TYPE III BARRICADE ADDITIONAL TYPE III BARRICADES MAY BE USED AS NEEDED 0 0 0 U, W20 -1A-48 TRAFFIC ALLOWED TO CROSS CLOSED ROAD ROAD CLOSED R11-2-48 ROAD CLOSED X MILES AHEAD LOCAL TRAFFIC ONLY R11 -3A-60 SEE OR OR ROAD CLOSED BEYOND JUNCTION BRIDGE OUT R11 -2A-48 BRIDGE OUT X MILES AHEAD LOCAL TRAFFIC ONLY NOTE 7 R11 -3B-60 W40-11-48 OPTIONAL W20 -3B-48 SIDE ROAD 5oo��b STOP W20 -1A-48 * WEST DETOUR NORTH 66 R1-1-30 * 66 W20 -3C-48 SIDE R1-1-30 1 500' W20 -1A-48 SIDE ROAD DETOUR NORTH 66 * COVER WITH 1 ROAD CLOSED X MILES AHEAD LOCAL TRAFFIC ONLY OR BRIDGE OUT X MILES AHEAD LOCAL TRAFFIC ONLY R11 -3A-60 R11 -3B-60 MOUNTED OVER DETOUR M4 -10L-48 WITH TYPE A WARNING LIGHTS MOUNTED ON TYPE III BARRICADE I 1 i I I I 1 I I 1 I I 0 0 In 0 0 In DETOUR 66 4 * m 1+ COVER WITH 500' W20 -2D-48 TOWN 4- TOWN TOWN XX XX 'XX -> CLOSED TO XXXX USE HWY XX 8. XX TO XXXX USE WHERE APPLICABLE 0 0 In 0 0 a7 W20 -2D-48 W20 -3A-48 W/TYPE A WARNING LIGHT MOUNTED ABOVE TYPE III BARRICADE * COVER SIGN COVERS OVER REFLECTIVE MATERIAL SHALL BE INSTALLED WITH SPACERS TO PREVENT DAMAGE NOTES 1. SIGNS SHOWN ARE USUALLY FOR ONE DIRECTION OF TRAVEL ONLY. 2. THE CONTRACTOR SHALL INSTALL, MAINTAIN, AND REMOVE ALL SIGNS IN ACCORDANCE WITH THE DETAILS OF AND AT THE LOCATIONS SHOWN IN THE PLANS. SIGNS INSTALLED BY THE DEPARTMENT OF ROADS OR OTHER GOVERNMENT AGENCY SHALL BE MAINTAINED AND REMOVED BY THEIR FORCES. 3. WHEN MESSAGE IS NOT PERTINENT, SIGNS SHALL BE TAKEN DOWN, COVERED OR FOLDED. TAPE IS NOT PERMITTED ON THE FACE OF THE SIGN. 4. VEHICLES OR EQUIPMENT SHALL NOT BE PARKED SO AS TO OBSCURE OR DISTRACT FROM TRAFFIC CONTROL DEVICES. 5. FLAGS MAY BE USED TO CALL ATTENTION TO WARNING SIGNS. 6. WHEN APPROPRIATE THE SIGN R11 -2B "BRIDGE OUT" MAY BE USED INSTEAD OF R11-2 "ROAD CLOSED". 7. BARRICADE AND SIGN MAY BE PLACED ALONG EDGE OF ROAD IF NEEDED FOR LOCAL TRAFFIC. 8. REFER TO STANDARD PLAN 920 FOR GENERAL INFORMATION NOT SHOWN. ROAD CLOSED AT JUNCTION ROAD CLOSED DETOUR LEGEND I I TYPE III BARRICADE • REFLECTORIZED PLASTIC DRUM SINGLE POSTED SIGN DOUBLE POSTED SIGN * INSTALLED BY OTHERS TAPER FORMULA L = S x W FOR SPEEDS OF 45 MPH OR MORE. L = 6o 2 FOR SPEEDS OF 40 MPH OR LESS. WHERE: L = MINIMUM LENGTH OF TAPER. S = NUMERICAL VALUE OF POSTED SPEED LIMIT PRIOR TO WORK. W = WIDTH OF OFFSET (LANE WIDTH). R11-2-48 M4-10-48 R1 JUN 19 2009 MUTCD UPDATES REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 923-R1 TRAFFIC CONTROL ROAD CLOSURE ACCEPTED BY FHWA FOR USE 0 NATIONAL HIGHWAY SYSTEM - ' -- FAf N68R• — JUNE 2014 DATE ORIGINAL: AUGUST 1998 DATE