Loading...
HomeMy WebLinkAboutPD2013-18, LOCK ILI .M9 STE I STE } e / c.ao N w xn° City of Hastings N w+E S JSTW.xms ». E ® Scale: None North Project Location 1-319y) PD 2013-1 MERLE AVENUE North Shore Drive to Lakeridge Drive INDEX OF SHEETS SHEET NO. 1 SHEET NO.2 SHEET NO. 3 SHEET NO.4 SHEET NO.5 TITLE SHEET DETAIL AND NOTES SHEET PLAN AND PROFILE SHEET STORM SEWER PLAN SHEET CROSS SECTION SHEET LEGEND 0 • * Utilities Director of Engineering Date 0 N Spot Elevation Utility Pole Control Point - Nail Set Control Point - Temporary Wood Hub Set Deciduous Tree Coniferous Tree Manhole Fire Hydrant Water Valve Gas Valve • 0 0 1912 Light Telephone Box Electrical Junction Box Contour Line — --------------- Property Line CALL BEFORE YOU DIG DIGGERS HOTLINE OF NEBRASKA 1-800-331-5666 Hastings City Surveyor Date SUMMARY OF QUANTITIES ITEM ESTIMATED NO. DESCRIPTION QUANTITIES UNIT 1 Mobilization 2 Saw Cut 3 Remove Header 4 Remove Pavement 5 15" Reinforced Concrete Storm Sewer Pipe 6 24" Reinforced Concrete Storm Sewer Pipe 7 Build Storm Sewer Curb Inlet - L=12' 8 Build Reinforced Concrete Collar 47B-3000 9 Furnish & Install Silt Fence, Low Porosity 10 Build 6" P.C.C. Pavement 47B-3500 11 Adjust Manhole to Grade 12 Curb Inlet Sediment Filter 13 Seeding - Type B NDOR Seed Mixture 14 Traffic Control Construction and Maintenance NOTES: 1.0 16.0 62.0 3.1 36.0 77.36 2.0 1.0 100.0 1230.11 1.0 40.0 L.S. L.F. L.F. S.Y. L.F. L.F. Each Each L.F. S.Y. Each L.P. 0.8 Acres 1.0 L.S. The embankment and subgrade shall be adjusted to conform to the lines and grades on the plans in accordance with Section 205 and 302 of the 2007 Standard State Specifications and its supplements. The upper six (6) inches of the subgrade shall be scarified, mixed and recompacted to the following compaction requirements: Percent Density Moisture Minimum Requirements Maximum 95 Min. Opt. -3% Opt. +3% Areas not meeting specified moisture density test requirements shall be removed and recompacted at the Contractor's expense. All subgrade compaction and water necessary for subgrade construction shall not be paid for directly but shall be considered subsidiary to the items of the contract. Excavation, backfilling, and sawing control joints, keyway, tie bars, dowel pins, and rubberized joint sealant shall be considered subsidiary to the unit price per square yard of pavement. Hastings City Engineer ,.CITY OF HASTINGS, ENGINEERING DEPT. 0 Project MERLE AVENUE - North Shore Dr. to Lakeridge Dr. Proj. No. Description Design By B.B. Drown By B.B. PD 2013-1 TITLE SHEET Dote 6/2014 Approved By Contractor Dm. No. 1 of 5 North Shore Drive a -0 99+00 25' 1 (2605) 1 120.00' Scale: 1" = 20' 2' 101+00 67.70' (2613) 3 102+00 NOTES: 1. Contractor shall protect all survey control points and Property Pins from damage. 2. Earthwork on this project shall consist of the street excavation, constructing to the lines and grades as shown on the plans and cross sections, and the disposal of excess excavation on the adjacent Lots and graded. This work shall be subsidiary to the Unit Price of Build 6" PCC Pavement. Approximately 464.0 C.Y. of excess excavation will be generated. All Excess Excavation shall be spread out and compactedon open Lots 13,14, & 15 and grades to blend into existing ground. All fill in excess of 6" shall be compacted to 90% of standard Proctor density with no less than 5% below optimum moisture. 3. Contractor shall call Diggers Hotline before digging to have all Utilities located. Please note the Utilities crossings that are shown on plans. 4. Transverse saw cuts shall not exceed 10' between joints. co O N O r 103+00 • 8' Water Main T 120.00' 68.07' 79.00' 86.52' 2 C m a 0 c 0. -4 0 0 0 m C J• m i 15 14 13 (2606) (2610) JOINT DETAIL (2614) ,.CITY OF HASTINGS, ENGINEERING DEPT. 10 0 Project MERLE AVENUE - North Shore Dr. to Lakeridge Dr. Proj. No. Description Design By PD 2013-1 B.B. Drown By B.B. Detail and Notes Sheet Date Contractor 6/2014p6py—�� � PpprovedihY V" Dr. No. 2 of 5 The locations of all aerial and underground utility facilities whetherI may not be indicated in these plans. Underground utilities, indicated or not will be located and flagged by the Utilities at the request of the Contractor. No excavation will be permitted in the area of underground CNI I CT) utility facilities until all such facilities have been located and 1--••• identified to the satisfaction of all parties. The excavation must be accomplished with extreme care in order to avoid c0 I + 00 any possibility of damage to the utility facility. 01 oil (/) Contractor shall drop curb for driveway on Lot 2 Lakeway Addition. Location to be determined in field by Engineer. 4: 0 I o 29 0 •=9 -..I / (?) Integral curb construction shall be subsidiary to the Unit Price 2 I of Build 6" P.C.C. Pavement 47B-3500. a_ 1 il C Curb Inlet Sediment Filter to be installed immediatexitrafter KA0e Q) Inlet Lid and throat construction. \lc o, • , I 0 2,,, • /0„. - CI3 1 . 0') tnI N t O 99+00 i i ii" nil g,'Sz 31' e, t4 sr 't• /0 CFO, --4 (4 toh tC>na Cot C I (..& . .9c, „I 91 ko , \\ V 70 ).. / 0 0 < <0 CO '92 I 0 t 4> 59 62 -a SCALES: 1" = 20' HOR 1" = 2' VER CI x41(0 ooe,r co + 0 2, 0 w .97 4-3 9 0 0 2/ 'e 24.64 TC 9i.:•.../7 24.06.FL ICO /0 Lc° 1992 ,-"-n> 24.14 FL 21/4,+,..t ss‘ •1/45= '9 / /9 I •Y•9 91/ • •96,0 to -15e x tri ° ez 0/ 24. id Xi t (4) i /9‘,/ficzi =Ste,. t 1 •=9 9 •it, •61.„‘ uil I /0 Cs 0 2,. 23.8 el 0 •e klitZW 0 ,.7,i0•2os..,‘t s 0 0724. 40 TC . .9"/, c/4Q 8" Water Main k?' / 2, `Q<D,72,i \ t'll /4/0 t• - 490 Frat i i 3 os orts 'it t„ i le1/4 F•e= i - 7t• -1 9 / Cn ,1 rn `tr " 0 0 e cop 2s. 0 '6' . 6 ',... 4 C I°79_, n . (2605) .C<i • 7 t 2 I 26. x0 •6‘.„ / --Q, 9,...> 1 cb 9) 1 i .7 e • :co, t i 1 0 ..... 101+00 i Od+JO err? 1 -4 ro ye 4i a Oa c9 < 0 •-•/. ' • , (2609) 120.00' 1••••••de. .1•41m.•••••011. *<\ • 7 24 66 TO 9 co 67.16' imohl.••••••••••••• 24.46 FL 0.64% .56 CL 8' San. Sewer Main tez P0' 1 '0,0 (2613) 9 20 .i 6' 2> 1/4t 3 II II R aro 102+00 poo'lp '0,9 2.> =rt•es 0 -a 26.24 TO C) 85.34 Prop. 24RCP Storm Sewer 100.. 26.56 TC REMOVE HEADER Station Side Lin. Ft. 98+87.92 LT & RT 31.0 102+44.08 LT & RT 31.0 Lots 13, 14, & 15 ADJUST MANHOLE TO GRADE Station Side Each 99+00 CL 1 03+00 25.42 FL 25.64 CL 26.00 CL 26.36 26.50 C 25 33 FL 25.69 F 0 Ce Ce CD • <t ), 3f.;, 9 to et I 24.75 TC C> /9, 120.08> ‘<c><9 20> '61/4 .1010M.••••••••• o. CD 3 0. 0 CD 0 0 ID CD SZ. 04 2.47 TC '<9 66.07, Zcit f •--1,3 79.00' C) tsi 6S 4saal, ) .2„.1,08 .`t=' Q ,o 47 Location of Ex ess Excavation to be spread and compacted to 90% standard Prpctor and graded to blend in to existing ground. 1 5 i 1 4 (2606)(2610) I *0, i 0/ 9 2 47 I 20, QO Oe ': i ,-->. 26.19 TC Curb Inlet Sediment Filter 26.55 TO 40.1 /"1° ° 0 00, '•/ k CC•0 •;';',„ f" 0, 010 c;••••00 I aki••>/- 6. 13 (2614) 'Giro .079 ‘40 xsi6, .07 e "0 • 0 .0,, w20 .9 '2 >.PQ '9 ,.> 0 •Pr p. 24" RCP Storm Sewer 00 BUILD 6" P.C.C. PAVEMENT 47B Station to Station Side Sq. Yards 98+78.12 to 98+87.92 RT 3.11 98+87.92 to 102+44.08 LT & RT 1227.0 Lots 13, 14, & 15 RT 0.5 SAW CUT Station Side Lin. Ft. 98+78.5 to 98+87.92 RT 16.0 101+63.3 RT 20.0 REMOVE PAVEMENT Station Side Sq. Yds. 98+78.5 to 98+87.92 RT 3.11 101+63.3 RT 20.0 /9. 9, +0 ../ 4, . •=9 .9 20 '99 9 0 2 2, / • 6'.7 '0 14 (>019 2ofe, Cu Qo 26, %se Si 91 V I, • Y '1/45‘ 0 2 /9 Q6, •o .07 \<>/.0. 0, '0 e •=e0 9 20, 60 "<>,7 2,9 '00 =3> •ev x79 ' 9 '49 CURB INLET SEDIMENT FILTER Station Side Lin. Ft. 101+63.3 LT 20.0 101+63.3 RT 20.0 SEEDING, TYPE "B" NDOR Mix Station to Station Side Acres 98+68 to 102+63 LT 0.15 98+68 to 102+64 RT 0.15 Lots 13, 14, & 15 RT 0.5 3 I3 ACITY OF HASTINGS, ENGINEERING DEPT. 00 Project MERLE AVENUE - North Shore Dr. to Lakeridge Dr. Proj. No. PD 2013-1 Description Plan and Profile Construction Sheet Design By R.D. Dote 6/2014 Contractor Drawn By B.B. Approved BY Can. No. 3 of 5 1932 TB.M - F.H: NE -corner Merle Ave./North.Sho e larlY Bonnet Bolt•w/arrow ointing to -it Elev. - 1925.73 T B:M. F..EL:SE Cerner Merle Ave./Lakekidge.Dave Bonnet -Bolt int/arrow-pointing-to it. Elev. - 1928.75 1932 1930 1928 1926 1924 1922 1920 1918 1916 VPI -STA = 99+00.06 VDI STA = 99+50.00 VPI -STA - -102+00.60 N 1926:56 1930 VPI -EL = -1924.13 • V°1 -EL = •1-9 4.56 P -EL - .1.926%36 II' g 1 0.83% 1 0 0.86% 1 0.72% g2 0.86%1 CURVE LEN' 0:00 0:00 g 2 = 0.72% 2 0.45% CURVE LEN = 0:00 CURVE _EN • -• 0:00 Lu 0 0 Lu 1928 Existing Cr.Grade co 0 op (-0 ko t---r7nIn▪ r-tn OCJ 0•C‘.1 • 0,00-1 0 + ciaine-s Proposed CL Grade r nire • coscr . k �t 0 hQ N • r Q) a) 1914 II II < LT] o_ 00 cci rn .P.: . ...1. ..4-, . .1-. 0 a a • la a a CO • a •X 2 •>7 = 2 ',7 9 ... we. .................. LP . g- .................. we. w . e- .......... CO NI CD - CO t--. 'et' CO • 0 OD CD If) N 0 <ID 0 0 -cr wi. cri 6 lc; (0 .0 N N N N N N en cb do do d> cb '-'A- Tr- 11- ,_,I- 'A-,.- "R)C ot a 4-- ..... 62 - ..... 1•••••• Co 04 (0 (Dr UD oi 1926 1924 1922 1920 1918 1916 .1-, to 6. 0 x =._ '37 ........ We. .................... 14 e co ................. ......... 0 (0 Co 1' 1914 98+00 8+50 99+00 9+50 100+00• 0+50 101+00 1+50 102+00 2+50 103+00 3+50 104+00 SCALES: 1" = 20' HOR 1"=2'VER C. 9 I N m '9, C N 99 00 9 V `9299 . •r�2F a 0 791 24.06 FL . ,9 `'3 9S 92 1 I 3,,5 R 0 7912' JO/ 2F '0, 24 i7 .923 9303 92301 790 2.6, «7 2 A 21/2 I e,.?/ ,TL' Q92. ?'9'T 1/2 J�92R 03 2 2 2 J' 9 9 a •7 92,9 3'3eo0 co a O BF 120.00' 24.64 TC 1 J926e • RR 24,85 TO iod+ /04 O3 -n 0 lormorrwrmin /87 ere•O'yt9 CL C, 24.14 FL 2�FF 24.13 CL 24.46 FL m 24.56 CL 8" San. Sewer Main 1 TO w 1 91-', 23S .2S J w f7979 23 '09 I I F 23.90 FL 4.40 TC 2C 8" Water Main R7 m0 r'7`). 5 0 SJ 25 f 34.25 FL 24.75 TC 0 79 120.9 ev J9 321 • 7J 28 TO '492s (2605) 97 1 920 F9 67.78' 25 0 TO 4 ti 25.92 X79 2 6078.00- 24.78 FL rn � �t� <9e a; 92sMerle Ave. 24.9922iCL 1 '79 ryry ?y i t ttJ 24131 FL 25.111 TC 02,9 29 Pro%b . . 6 — _ .n Underground Telephone Line E Nowasoa ,o/ ___ .O3 25. U� 25 cps 2 es 2 47 TO ---‘4/7 04/7 68.07p • S7 n 079 2s 7F 15 (2606) 2S L 25.83 C a -o n 20 '02 F7 9 i 2J 3F 26.24 TO 25.74 FL 26.00 CL .89 FL 79.00' 14 26.19 TC 2 N 3N U) 079 20 (2613) 3 102+00 N 0 0 ' <9 926. O j9 cDo Ka ;o 85.34' FJ .9 6 9 Prop. 24" RCP Storm Sewer 26,56 TO 26.06 FL 266.36 CL 26.05 0.64% `�J02j -c 0 LU. 23 26. 26. B. Sta. 10. Contras City En Build C +40.66 Approx. end of Existing 24" R.C.P. or to expose exist. flowline and contact ineering Dept. to verify Elevatiow7 ncrete Collar 47B-3000 so 00 03+00 0 .72 c/'9 0801 6' (to .04ei 9 ‘'S 0 09 •2J OJ /79 20 BUILD REINFORCED CONCRETE PIPE No. Slope Size Length Description 0 0.32% 24' 77.36' End of Exist. Pipe to Inlet #1 Q 0.44% 15" 36' Inlet #1 to Inlet #2 (CL Box to CL Box) 2 101+63.3 RT 1926.29 1920.87 BUILD STORM SEWER CURB INLET PLAN 443-R8 No. Sta./Offset Rim Elev. Flowline "X" "Y" 101+63.3 1 50.0 101+63.3 LT 1926.32 1920.71 5.11' 12' 2 101+63.3 RT 1926.29 1920.87 5.42' 12' .0 BMW Concrete Collar 47B-30%0 Station Side '2-?,, Each 102+40.66 LT 1 101+63.3 RT 50.0 '0J, 9j3O 'F, 'F 920 92j 92 4 '9 JErep. 24' RCP Storm Sewer TO �99e 2_NET `920 re V 0 F 9 U `b ''<J J t926 0 920 •SO 20 26. I I i i I 26,55 TC rorrmrdrml 86.52' 13 (2614) 79 2J 07920 so 60 F, 26.99 92'6, 0.'C 9_ s� T� 9, w 715 f .6140 OF F7 6' J H 790 20 . 09, 'S .2 70 26,E J9 2�6y22 20. •CIp o YJ 07 20 6> SO (79 20 "S T B.M: _ F.H. E :Cornier Merle Ave7Ndrth:Sh& - Drive Bon et Boltw/arrow ointing to it Elev. =1.925.7 /7 5 • 92''a 0J�J evo 9 9„ 92 RO S2 '9 99 0 '079 29 9i C - FURNISH & INSTALL SILT FENCE, LOW POROSITY Station Side Lin. Ft. 101+63.3 LT 50.0 101+63.3 RT 50.0 NOTE: Existing 24" R.C.P. is stubbed out to approx. the south end of concrete return at Lakeridge Drive. Contractor shall expose existing flowline of pipe. City Engineering staff will verify elevation and make necessary adjustments to proposed 24" Storm Sewer and Inlets. .9 80 9 079 27 Silt Fence to be installed immediately following backfill operation of Inlet Boxes before Pavement Construction. yit40 HUEr,rr¢ 760160\kaE E. SS/0 aprnpa e4 , m4�e .f ^moo DAVL 6;1 WACKERID > ' °�• t��am E -5030b r T ®° 'e T B:M.:= F..H.:SE Corner Merle Ave./Lakekidde:Dave Bonnet'Bolt WI- rrow'pointing'to t. Elev. =.1928.75 '0779 20 'F, 07j9 29 's /. CITY OF HASTINGS, ENGINEERING DEPT. Project MERLE AVENUE - North Shore Dr. to Lakeridge Dr. Prof. No. PD 2013-1 Description Storm Sewer Plan Sheet Design By 8.8hn i ei lAaheffiWafter Plan Date 6/2014 Contractor Drown By B.B. 1932 Sta..101+6.3:3. Curb Inlet '. FL -Pipe'= 920.71 Rim Elev. 1926.32 0 i 55.01 -Ft :24in :RCP :-0,31% �24in •RCP 'EJL 1920:46 Sta. 102+40.66 Approx. End of Pipe FL Pipe '= 1920.46+- d m O N a`w (0 04 OR CT? LI) <t N N 1914 Y O 0 x d'0' 2:so 11 Lai co O 10 �.ds cis (0 Y Y- o. w `w N c0 .0 CO 0 0 CO 0) Y- [ N 2 'x 0.w aw 0 N to 98+00 8+50 99+00 9+50 100+00 0+50 1 01 +00 1+50 102+00 2+50 103+00 3+50 Approved By Dm. No. 4 of 5 1932 1930 is N o 'w aw 1928 1926 1924 1922 1920 1918 1916 104+00 1914 70 00 60 00 50 00 40 00 30 00 20 00 10 00 10 00 20 00. 30 00 40 00 50 00 : 60 00• 70 00 70 00: 60 00 50 00 40 00 30 00 20 00 10 00 10.00:: :2000. 30 00 40 00 50 00: 60 00 70 00 Dirt Quantities:.t.. 465 25:C.Y. Excavation .63 C.V.: :Emban:kment:(1:3 Comp: :Factor use 0-i 1- u_ S. I 1003 5 ' 1929 00 NN :=50_09_1_04L8_8 0 0 - CP r ......... 0 CO u, N N. S. J Lt. I- o......... . ......... 01.02 gal 46:3.62 .C.Y. of Excess: Excavation 930 00 0) N In •• LI +a0) 4,0 I 6 ORI GINAL • . 59: " CO 1-6 . a I.Air ar ect• ..... N. . . kr) . ..... 02 • . . cn N • ....... M. 100: q7fl 00 th -.- co • a77,7 to FILL AREA • =0;00 CUT 2 44.08 Lo. to Po to er; • N • • N Ti 0 ro. N 01 co • Pc>tei SPA, = OR GINAL: :E_ -.1926.50V en - Low o •0 ' 05 DESIGN EARTH:WORK to 0 c6 5 00 102 • to ) 44.08 • • Eli L AREA"=0 00 q.7f 00 GUT:AREA- =15.92-S.F. AREA = 6.66 S 1930 on S. 1.-u- (0(0 0 O CO 0 N NN CO 1925 00 (01 -6 r N N _J Li_ • LOU, OU) N• N q.3() 00 9 INNIMINEMBIONIMS N ....,....Th r r ,....:. . o) : @ Ci if I. Cr} N ORIGINAL NA =1925.36 . , ci (1) • II ci s s N to 29.27,1.925.37 925 0 00: 2 0 1995. ..... • • ....... •OZ ' 00 C FILL AREA' =0.00 re, en • co U) ......... 01 .... • • -7- -=-141024404f :E ‘1926.02 •ig OR GIN:41: 7 1. 19-2000 DESIGN: EARTHWOR:< N 03 N 05 di 01 N N 0> a) N UT 'AREA 40.31S F -UT AREA =39:98. •S.F. • LL la 00 • 16 • al CO CO tri N 9 0 _I- F- U 0 0 N"et N 0 0 N 0 NN • 6 0 CO Le? LL CO• CO <le • eet N N N N J Ti /.." CN N S. • 0 r r +Se +.7_9-4 OR GINAL: :EL =1-925.22:7i 925 00 C C'. a (0 03 50 192500 III * II <0. 995-00- 1 ce 0) ..... : : 157 RCP 4t1 RC 01 CO C 920 00 0 Co N FILL.AREA =0:00 SPA = +63,30 CU T: :AREA : -43:53 S.F. OR GINAL EL 1926.61 DESIGN: :EART:HWORK f ILL AREA =0:00 GUT AREA: :=:38:62: S.F. 19-30.00 9 Das 1920- Of ......... 0i u - *Tr •cte cc? r N N -J 0 r N J • 0 LL Fe 0. 0 C7 01 • 'I- N CV ' • I I 6 • 1 -Li- Cm <0 in NN .i0 I.LI- 00) CO l - in cm 930 00 - • 6 99: C. SPA =SS+ OR GINAL N N -1923.67 • 'x:• N 0 CP u-) DESIGN ERTHWOR N to es7:: N a7-7 U) to 00: 101 CC) 50 N e3 - r: CO N co 7-77 1,0 co en 1 c a 05 ) to) • U) CO Ti G:IN:AL: .E _ =1*:26 53 kba 92,5L-00- 1 H N 0) rg 990• 00 0) 192000 DESIGN' EARTHWORK FILL AREA • =0:00 N N 0) di U) N ere 920:000 FILL: 'AREA =1 .09.. Cu T :AREA =39.33 SF U AREA =14:81 S:F. 1930 00 93n 00 1930 0 O -I CO W 8 NY N ..J .J 0 U- F- CO Cti CO 1 - CO "4 N NN 8792. J-99 5-00 C) "cl 920 00 -r3.54,1924:84 • • • • • • • • co 4 . -.1-..87..92 cc, / 01 N,til • SIVA SS + 87.92 4 N . .9, . cc„‘,3 ta co 4DN IN en ri ..s -c OR GIN:AL: .ei_ . . 1924.03:0' • " (Poo eN7 n N a: 9) Oi oc CO C • IC „7:7 - ' 920. ?lc) tin wei4T7: ....... 2"----1.77777 ............. N e i tc -an • • cii71-: ' .... • ' 7,.1: . --1- • • • ree, N re: /CITOE'l 'o&e. V. O i J LL 0 N N 1st O .4' c4 LOU) in N N N -'-0 U- . CO 0 0 LOU) NC') 930 00 10 to N • 0). .... .... 1 .. .. "Pa =.•.10.1.10.1 .... • •t -g • • ORitINAL •L =142-6 07 • ..c`4 • . -C 25 . . . • N to (0 ... n ..... 1g, 0) 0 C‘ • 00 DESIGN: ECARTHWORK 1920 0 DESIGN- EARTHWORK FILL AREA: j-0.00 ,e0 N Co CO 00 in 1920.00 cb ELL AREA- -0.00 CUT AREA 35:67S;F. CUT . A:REA. =17.28 SF 70 00 60 00 50 00 40 00 30 00 20 00 10 00 10 00 20 00 30 00 40 00 50 00 60 00 70 00 70 00 60 00 50 00 40 00 30 00 20 00 10.00 C 1000 20 00 30 00 40 00 CITY OF HASTINGS, ENGINEERING DEPT. 1710 Project MERLE AVENUE - North Shore Dr. to Lakeridge Dr. Proj. No. PD 2013-1 Description Cross Section Sheet Design By R.D. Dote 6/2014 Contractor Drawn By B.B. Approved By Dm. No. 5 of 5 Roadway Design Division M L O JOINT SEALANT FLOW 1" 9„ 8" 1" PREFORMED EXPANSION JOINT FILLER CONCRETE BARRIER CURB QUANTITIES CONCRETE 4.55 CU. YDS./STA. AREA 1.228 SQ. FT. JOINT SEALANT 9„ 1" PREFORMED EXPANSION JOINT FILLER CONCRETE MEDIAN CURB QUANTITIES CONCRETE 4.42 CU. YDS./STA. AREA 1.192 SQ. FT. NOTE: ONE INCH PREFORMED EXPANSION JOINT FILLER SHALL BE PLACED AT INTERVALS OF NOT MORE THAN 100' THRU CONCRETE BARRIER CURB, CONCRETE MEDIAN CURB, AND CONCRETE CURB, TYPE I. 9„ 1" 8" r1" R C ' ♦ s ♦ L G a o p A A A• > • d e A s A' _ p A. D . • NOTE: MAY BE USED WHEN T IS LESS THAN 12" INTEGRAL CONCRETE BARRIER CURB QUANTITIES CONCRETE 1.33 CU. YDS./STA. AREA 0.359 SQ. FT. NO. 4 LONGITUDINAL BAR TO BE GAPPED AT CONTRACTION JOINT LOCATIONS; 3" MIN., 6" MAX. NO. 5 x 8" TIE BARS AT 5'-0" CENTERS NOTE: USE WHEN T IS 12" OR GREATER INTEGRAL CONCRETE BARRIER CURB ALTERNATE TYPE QUANTITIES CONCRETE 1.33 CU. YDS./STA. AREA 0.359 SO. FT. 1'-0" A • A •• A A' ♦ e ♦ zkr INTEGRAL CONCRETE SLOPING CURB QUANTITIES CONCRETE 0.62 CU. YDS./STA. AREA 0.167 SQ. FT. 1'-0" A A • t D ♦ > p. :A • . A p D e . p • INTEGRAL CONCRETE SLOPING CURB QUANTITIES CONCRETE 0.46 CU. YDS./STA. AREA 0.123 SQ. FT. CONTRACTION JOINTS SHALL BE CONSTRUCTED TO MATCH LOCATION OF EXISTING JOINTS EXISTING CONCRETE PAVEMENT JOINT SEALANT FLOW A X, R 1,-0" 11 1" PREFORMED EXPANSION JOINT FILLER FLOW 1,-0" CONCRETE CURB,* TYPE I QUANTITIES CONCRETE 5.22 CU. YDS./STA. AREA 1.408 SQ. FT. NO. 4 LONGITUDINAL BAR TO BE " GAPPED AT CONTRACTION JOINT LOCATIONS; 3" MIN., 6" MAX. R THE AREA BETWEEN CURB AND EXISTING CONCRETE PAVEMENT TO BE CLEANED AND ROUGHENED AS DIRECTED BY THE ENGINEER 3" NO. 5 x 8" TIE BARS AT 5'-0" CENTERS TO BE DRILLED AND GROUTED INTO EXISTING CONCRETE PAVEMENT (WITH APPROVED GROUT) CONCRETE CURB, TYPE II QUANTITIES CONCRETE 0.87 CU. YDS./STA. AREA 0.234 SQ. FT. 9„ e . e ♦ - - p A ♦ .e A' •d' • A p • a EROSION CONTROL CURB QUANTITIES CONCRETE 0.81 CU. YDS./STA. AREA 0.219 SQ. FT. INTEGRAL CONCRETE CURB QUANTITIES CONCRETE 0.89 CU. YDS./STA. AREA 0.239 SQ. FT. No. 4 LONGITUDINAL BAR TO BE GAPPED AT CONTRACTION JOINT LOCATIONS; 3" MIN., 6" MAX. SAW CUT 4" MIN. DEPTH x %" JOINT FILLER RESERVOIR CONTRACTION JOINT THRU CURB NO. 5 x 8" TIE BARS AT 5'-0" CENTERS INTEGRAL CONCRETE CURB ALTERNATE TYPE QUANTITIES CONCRETE 0.87 CU. YDS./STA. AREA 0.234 SQ. FT. NOTE: T = PAVEMENT THICKNESS RIO R9 R8 REV. NO. FEB 09 MAR.05 MAY 01 DATE MULTIPLE REVISIONS MULTIPLE REVISIONS MULTIPLE REVISIONS DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 30 I -R I 0 PAVEMENT DETAILS ORIGINAL: JANUARY 3 I , 1974 DATE Roadway Design Division C M Uo 0 O N a) O^Ow fM 0 V) NOTES: 1" DIA. x 18" DOWEL BARS, T=6" TO 8" 1" DIA. x 18" DOWEL BARS, T OVER 8" EXPANSION TUBE EXISTING SLAB NEW SLAB GREASE DOWELBAR ON EXPANSION TUB SIDE 1" PREFORMED EXPANSION JOINT FILLER JOINT SEALANT DOWEL BARS SHALL BE DRILLED TO A DEPTH OF 8" INTO EXISTING SLAB AND GROUTED. DOWEL BARS SHALL BE PLACED AT 1'-0" CENTERS. THE OUTSIDE DOWEL BAR SHALL BE PLACED 6" FROM THE EDGE OF THE SLAB. THIS JOINT SHALL BE CONSTRUCTED TRANSVERSE TO THE ROADWAY WHERE THE NEW CONCRETE ABUTS THE EXISTING CONCRETE. DOWEL BARS SHALL BE PLACED PARALLEL TO THE ROADWAY € AND TO THE ROADBED. EXPANSION JOINT (SUBSIDIARY) NO. 5 x 18" TIE BARS AT 33" CENTERS TO BE DRILLED AND GROUTED INTO EXISTING SLAB. ASPHALTIC CONCRETE S 1,-0" • • 9'4 s. . • ! n . s. • • EXISTING SLAB -' VARIABLE CONCRETE BASE COURSE W/INTEGRAL CURB EXISTING SLAB NO. 5 x 18" TIE BARS AT 33" CENTERS TO BE DRILLED AND GROUTED INTO EXISTING SLAB. • • e ' s • • a e e e VARIABLE 1,-0" > D > D • • o • ' e • • • s • • • THE FOLLOWING NOTE IS TYPICAL FOR CONCRETE BASE COURSE W/INTEGRAL CURB AND CONCRETE PAVEMENT WIDENING: CONTRACTION AND EXPANSION JOINTS SHALL BE CONSTRUCTED TO MATCH LOCATIONS OF EXISTING JOINTS. CONCRETE PAVEMENT WIDENING ONE INCH PREFORMED EXPANSION JOINT FILLER SHALL BE PLACED ACROSS THE FULL WIDTH OF THE MEDIAN SURFACING AT INTERVALS OF NOT MORE THAN 49'-0'. LONGITUDINAL JOINTS ONE INCH DEEP SHALL BE MADE IN ALL MEDIANS WHEN SURFACING WIDTH IS 16' OR GREATER. TRANSVERSE JOINTS ONE INCH DEEP SHALL BE MADE IN ALL MEDIANS AT INTERVALS OF NOT MORE THAN 8'. TRANSVERSE AND LONGITUDINAL JOINTS SHALL NOT BE FILLED. JOINT SEALANT 3' MIN. SLOPE 2'. i J R . 4 R .: 1" PREFORMED EXPANSION JOINT FILLER JOINT SEALANT L DETAILS OF CONCRETE MEDIAN SURFACING 1" PREFORMED EXPANSION JOINT FILLER 1,-0" 2" v A jti r VARIABLE ONE INCH PREFORMED EXPANSION JOINT FILLER SHALL BE PLACED AT INTERSECTION RETURNS AND WHERE SHOWN ON THE PLANS. TRANSVERSE JOINTS SHALL BE PROVIDED EVERY 8' OR WHERE SHOWN ON THE PLANS. NOTE: RECESS THE EXPANSION JOINT FILLER %" FROM THE TOP SURFACE OF THE CURB TYPE UNDER CONSTRUCTION DETAIL FOR CUTTING EXPANSION JOINT FILLER VARIABLE (2'-0" MIN. TO 3'-6" MAX.) COMBINATION CONCRETE CURB & GUTTER 12" OPENING FOR SIGN POST SIM A 1'-6" 4' MIN. 1" PREFORMED EXPANSION JOINT FILLER W/JOINT SEALANT 12" OPENING FOR SIGN POST B PLAN A 4" MEDIAN SURFACING 1'-6" 4 MIN. JOINT SEALANT zot 1" PREFORMED EXPANSION JOINT FILLER SECTION A -A DETAIL AT END OF MEDIAN ISLAND LENGTH AS SHOWN ON PLANS 8' MIN. FOR 6" CURB 6' MIN. FOR 4" CURB 1" PREFORMED EXPANSION JOINT FILLER W/JOINT SEALANT 4" MEDIAN SURFACING - 4110 - net ar NaNglia 1'-6" II 1" PREFORMED EXPANSION JOINT FILLER A 4' MIN. JOINT SEALANT 1 _C PLAN R_, > D > • > • • • TOP OF SLAB SECTION C -C a a SECTION B -B CONCRETE ISLAND NOSE D CONCRETE PAVEMENT SECTION D -D NOTE: EXISTING CONCRETE PAVEMENT IS TO BE REMOVED IN AREA COVERED BY CONCRETE ISLAND NOSE. DETAILS OF CONCRETE ISLAND NOSE LEFT IN PLACE CONCRETE HEADER NOTE: T = PAVEMENT THICKNESS B RIO R9 R8 REV. NO. FEB 09 MAR.05 MAY 01 DATE MULTIPLE REVISIONS MULTIPLE REVISIONS MULTIPLE REVISIONS DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO.301-RIO P VEMENT DETAILS ORIGINAL: JANUARY 31, 1974 DATE C 0 Roadway Design 1'-0 = - s e s ♦ s s s s s • s • s ♦ A A A • , • A ' O ' , • O INTEGRAL CURB JOINT SEALANT 1" PREFORMED EXPANSION JOINT FILLER DETAILS OF CURB DROPS R BARRIER CURB 5' WALK (4' MIN.) SIF G \. VARIES N • R X 5' 3.00' 10' 4.36' 15' 5.38' 20' 6.24' 25' 7.00' 30' 7.68' 35' 8.31' 40' 8.89' F 1'-0" X R = RADIUS X = (X & R IN FEET) G La CONTRACTION JOINT E #4 REBAR, 4'-0" LONG DRIVEWAY PLAN 2" SLOPING CURB 4' MIN. , e• A • • e • ♦ , , e A e e A ' A ' • A'• • t.tya • e . ♦ ♦A ♦ ♦ ♦ o I SECTION E—E (RURAL DRIVEWAY) 1,_0„ JOINT SEALANT 1" PREFORMED EXPANSION JOINT FILLER SECTION E -E (URBAN DRIVEWAY) JOINT SEALANT 1" PREFORMED EXPANSION JOINT FILLER SECTION F -F (URBAN DRIVEWAY) TOP OF CURB + 0" MINIMUM TRANSITION SIDEWALK TO MEET DRIVE (DISTANCE VARIES) RISE LESS THAN 6" (8% SLOPE) RISE GREATER THAN 6" (5% SLOPE) SLOPE io A A e A s sf2TA' " VARIABLE i SECTION G -G LD R=RISE d-34» ! .s A. .'e. ."e. •"A• M"R s -E ,T s e s s - s s� . s >' e• e -s • , • , 'A • , • A VARIABLE CROSSWALK DRIVEWAY SLOPE TOWARD STREET 2% ryt" p D u .g„ p VARIABLE (3) SIDEWALK 10' DES. (4' MIN.) C M o, LL P o iD O M o o:w 0 0 N (1) 10' MIN. IS REQUIRED WHEN THE EXISTING GRADE IS GREATER THAN 218: (2) 10' MIN. IS REQUIRED WHEN THE EXISTING GRADE IS GREATER THAN t15% (3) 10' MIN. ROUNDING IS REQUIRED WHEN THE EXISTING GRADE IS GREATER THAN +22% 5' SIDEWALK (4' MIN.) (1) PROFILE URBAN DRIVEWAY WITH SIDEWALK (MAXIMUM PERCENT OF GRADE) NOTE: 1" PREFORMED EXPANSION JOINT FILLER SHALL BE PLACED IN ALL SIDEWALKS OR CROSSWALKS AT INTERVALS OF NOT MORE THAN 50'-0", AND AT ALL POINTS WHERE SIDEWALKS OR CROSSWALKS ARE ADJACENT TO CURB. IF SIDEWALK OR CROSSWALK TO BE CONSTRUCTED IS LESS THAN 50'-0" IN LENGTH, ONE SUCH EXPANSION JOINT SHALL BE PLACED AS DIRECTED BY THE ENGINEER. NOTE: T = PAVEMENT THICKNESS RIO FEB 09 MULTIPLE REVISIONS R9 MAR.05 MULTIPLE REVISIONS R8 MAY 01 MULTIPLE REVISIONS REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 30I -RIO PAVEMENT DETAILS ORIGINAL: JANUARY 3 I , 1974 DATE Roadway Design Division C o in® N 0 SIDE ELEVATION L 6 D 6" 2" BARS IN SIDE BENT AS SHOWN VERTICAL BARS BARS IN TOP BENT AS SHOWN 2" -TRANSVERSE BARS N BARS IN BOTTOM BENT AS SHOWN DETAILS OF COLLARS L/2 IZI CUT MESH ALONG ANGLE LINE 2 ° r �I 14" MIN. MUIM NO. 4 x 30" BARS CENTERED ON CUT CUTTING DETAIL WELDED WIRE FABRIC CAGES 12" THROUGH 24" PIPE DIAMETERS MIN. BAND THICKNESS VERTICAL BARS BARS IN SIDE o BENT AS SHOWN V N TRANSVERSE BARS END ELEVATION 4"x 4"-W2.1 x W2.1 WELDED WIRE FABRIC MORTAR FILLED JOINT NO. 4 BARS WELDED WIRE FABRIC WELDED WIRE FABRIC DETAILS OF CONCRETE ELBOWS WELDED WIRE FABRIC CAGES OVER 24" PIPE DIAMETER BAR LOCATION DETAILS BENDING DETAIL DATA FOR PRECAST ELBOWS SIZE OF PIPE 'U° MINIMUM BAND THICKNESS 0 MAXIMUM L=6' L=71/2' 12" 1" 90° 90° 15" 1" 90° 90° 18" 1" 90° 90° 21" 1" 90° 90° 24" 1%" 90° 90° 27" 1%" 90° 90° 30" 1%" 90° 90° 36" 1%,, 81 ° 90° 42" 1%" 73° 90° 48" 1%" 66° 88° 54" 2" 60° 81° 60" 2" 55° 75° SCHEDULE OF BARS FOR COLLAR SIZE OF PIPE I NUMBER OF BARS °D° dArc acct TRANS -VERT TOP ONE SIDE BOTTOM 12" NO. 4 12 4 2 4 15" NO. 4 12 4 2 4 18" NO. 4 12 4 2 4 21" NO. 4 12 4 2 4 24" NO. 4 12 4 2 4 27" NO. 4 12 4 2 5 30" NO. 4 12 4 2 5 36" NO. 4 12 4 2 5 42" NO. 4 12 5 3 6 48" NO. 4 12 5 3 6 54" NO. 4 12 5 3 6 60" NO. 4 12 5 3 6 DATA FOR COLLARS SIZE OF PIPE 'D' A CONCRETE (CU. YDS.) REINF. STEEL (LBS.) 12" 0° 0.30 32 15° 0.33 33 30° 0.36 36 45° 0.39 37 15" 0° 0.36 35 15° 0.40 36 30° 0.43 38 45° 0.47 40 18" 0° 0.42 38 15° 0.49 41 30° 0.56 44 45° 0.64 46 21" 0° 0.47 40 15° 0.55 42 30° 0.64 46 45° 0.74 48 24" 0° 0.53 43 15° 0.63 45 30° 0.74 49 45° 0.86 51 27" 0° 0.57 45 15° 0.70 48 30° 0.84 52 45° 0.99 55 30" 0° 0.63 49 15° 0.79 53 30° 0.96 57 45° 1.14 61 36" 0° 0.77 53 15° 1.01 58 30° 1.26 63 45° 1.53 68 42" 0° 0.96 65 15° 1.32 72 30° 1.69 80 45° 2.09 91 48" 0° 1.16 68 15° 1.66 77 30° 2.19 86 45° 2.75 95 54" 0° 1.34 75 15° 2.01 84 30° 2.70 95 45° 3.44 106 60" 0° 1.54 77 15° 2.39 89 30° 3.28 100 45° 4.23 113 NOTES: THE DIMENSIONS FOR CONCRETE PIPE SHOWN ON THIS PLAN ARE FOR CLASS III REINFORCED CONCRETE PIPE, AASHTO DESIGNATION M170, WALL "B". ALL QUANTITIES ARE BASED ON DIMENSIONS SHOWN ON THIS PLAN. NO ADJUSTMENTS WILL BE MADE IN THESE QUANTITIES IF OTHER STRENGTH STANDARD PIPE IS FURNISHED IN ACCORDANCE WITH THE SPECIFICATIONS OR IF COLLARS ARE USED ON PIPE OTHER THAN CONCRETE. WHEN A CONCRETE COLLAR, CONNECTING EXISTING AND NEW CONCRETE PIPE, IS CONSTRUCTED WITH A BEND, IT SHALL BE CONSIDERED AS A COLLAR NOT AN ELBOW. ALL REINFORCING STEEL USED SHALL CONFORM TO THE REQUIREMENTS OF THE ASTM DESIGNATIONS A615/A615M, GRADE 60. ALL BAR DESIGNATIONS ARE IN CUSTOMARY U.S. UNITS. ALL CONCRETE USED SHALL BE CLASS 47B-3000. FOR A SINGLE LINE OF REINFORCING WIRE MESH, TIE REINFORCING BARS ON THE OUTSIDE OF THE CAGE. FOR A DOUBLE LINE OF REINFORCING WIRE MESH, TIE REINFORCING WIRE MESH ON THE INSIDE OF THE OUTSIDE CAGE. REINFORCING BARS SHALL BE LAPPED WHERE THE BEND IS MADE. REINFORCING WIRE MESH SHALL BE LAPPED AND TIED WHERE THE BEND IS MADE. WELDED WIRE FABRIC OR EQUAL SHALL BE LAPPED 12" AT SPLICES. THE ORIENTATION OF THE PIPE SHALL BE MARKED WHEN CASTING TO ASSURE ADEQUATE REINFORCING BAR EMBEDMENT AND PROPER ALIGNMENT WHEN CUTTING AND ROTATING. ALL PIPE DIMENSIONS SHOWN ARE NOMINAL. R4 JAN 07 REMOVED REFERENCE TO CONC. AX -3000 R3 AUG 99 COMPUTER FILE/CHANGES R2 AUG 82 REVISED ELBOW CONSTRUCTION REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 425-R4 COLLARS AND ELBOWS FOR CONCRETE PIPE ROADWAY DESIGN DIVISION Computer: DRDESIGN173 User: dor13182 28-0CT-2013 09:06 0 C LIFT BAR - BAR D -LIFT BAR BAR E- BAR G - BACK COVER BAR A - BAR E PLAN INLET COVER 11 4'-0" " REINFORCING BAR BENDING DIAGRAM FOR CURB INLET 7" as - BAR E 11 2'-5" 7" 1L BARF 1 1'-01, BAR H € LONGITUDINAL PIPES -\\_ ANCHOR BAR ' 2'-10" 1`-10' ANCHOR BAR LOCATION OF BACK WALL WHEN LONGITUDINAL PIPES ARE NOT USED BACK OF CURB 10' N- I 7" BAR 1 j 2 W=D -(6"+T) SLOPE VARIES (ADJUST IN FIELD) 10". i' 1 I -I _or 11 it I GUTTER LINE II II II II WARP GUTTER TO FIT TEMPLATE PLAN Y = 4'-0" FLOW € TRANSVERSE PIPE WARP GUTTER TO FIT TEMPLATE 5`-0" TOP OF CURB 1'-6" 5" THROAT OPENING 1'-61: 51-0" LIMIT OF GUTTER DEPRESSION I 41-01, FRONT ELEVATION GUTTER LINE A N N LIFT BAR BAR G BAR D BAR C ADDITIONAL LIFT BAR FOR OPENINGS OVER 8'-0" BAR B LIFT BAR L_L_L Li BARE BAR G BACK COVER € LONGITUDINAL PIPES I, BARA BAR E PLAN INLET COVER 4'-0' 1/ BAR F REINFORCING BAR SCHEDULE FOR CURB INLETS DATA FOR CURB INLETS BAR SIZE SHAPE Y=4'-0" Y = 6'-0" Y = 8'-0" Y=10'-0" Y = 12'-0" Y = 14'-0" Y = 16'-0" Y=18'-0" N0. LENGTH NO. LENGTH NO. LENGTH NO. LENGTH NO. LENGTH NO. LENGTH NO. LENGTH NO. LENGTH A 8 STR. 3 1 " 6 -9 3 1 it 8 -9 3 1 " 10 -9 3 t " 12 -9 3 1 " 14- 9 3 I " 16 -9 3 1 " 18 -9 3 1 20 -9" B 6 STR. -- -- 2 I 4 -10 2 1 " 6 -1d 2 1 " 8 -10 2 1 " 10 -1d 2 1 " 12 -10 2 I " 14 -10 2 1 " 16 -10 C 6 STR. 3 2'-0" 1 2'-0" 1 2'-0" 1 2'-0" 1 2'-O" 1 2'-0" 1 2'-0" 1 2'-0" D 6 STR. 1 5'-1" 1 5'-1" 1 5'-1" 1 5'-1" 1 5'-1" 1 5'-1" 1 5'-1" 1 5'-1" E 5 BENT 6 4'-0" 6 4'-0" 6 4'-0" 6 4'-0" 6 4'-0" 6 41-0" 6 4'-0" 6 4'-0" F 5 BENT -- 2'-7" 3 21-7" 6 2'-7" 8 2'-7" 11 2'-7' 13 2'-7" 16 21-7" 18 2'-7" G 5 BENT 5 V-7" 4 l'-7" 4 1'-T' 4 V-7" 4 V-7" 4 11-7" 4 11-7" 4 V-7" H 4 BENT -- -- 10 W=4'-0" 10 W=4'-0" 10 W+4'-0" 10 W+4'-0" 10 W+4'-0" 10 W+4'-0" 10 W+4'-0" J 4 STR. -- -- -- -- -- -- -- -- -- -- 2 21-2" 2 2'-2" 2 2'-2" K 4 STR. -- -- -- -- -- -- -- -- -- -- 4 V-9" 4 1'-9" 4 11-9" LIFT 4 BENT VAR. 2'-6" VAR. 2'-6" VAR. 21-6" VAR. 2'-6" VAR. 2'-6" VAR. 21-6" VAR. 2'-6" VAR. 2'-6" M 4 STR. VAR. 5'-1" VAR. 5'-1" VAR. 5'-1" VAR. 5'-1' VAR. 5'-1" VAR. 5'-1" VAR. 5'-1" VAR. 5'-1" N 4 STR. 8 B-3 8 B-3 8 B-3 8 B-3 8 B-3 8 B-3 8 B-3 8. B-3 ANCHOR BAR 2'-10" . P-10" m LOCATION OF BACK WALL WHEN LONGITUDINAL PIPES ARE NOT USED BACK OF CURB °p -- -I- -I-7- 11 i II - --1-i- GUTTER LINE WARP GUTTER TO FIT TEMPLATE I II II II II € TRANSVERSE PIPE Y = 6'-0" TO 18'-0" fpr 0' -I r N WARP GUTTER TO FIT TEMPLATE FLOW 5'-0" 1'-6" TOP OF CURB THROAT OPENING 2'-011 5„ P-6" 5'-0" LIMIT OF GUTTER DEPRESSION CURB INLETS 4- 30" - 30" MAX. 16" (TYP.I 0 I 8" 4'-0' FRONT ELEVATION GUTTER LINE T = 9" EXCEPT FOR THE FOLLOWING: T = 6" FOR 6'-0" TO 18'-0" OPENINGS WHEN X = 2"-11" THRU 3'-1" T = 1'-6" FOR 14'-0" TO 18'-0" OPENINGS WHEN X = 3'-11" THRU 7'-5" LOCATION OF BACK WALL WHEN LONGITUDINAL PIPES ARE NOT USED B m 1" NON SHRINK BEDDING GROUT 0 "X" SHALL NOT EXCEED 7'-6". 2Q "A" SHALL NOT EXCEED 10'-0". 0 NO DEDUCTIONS WILL BE MADE FOR PIPE OPENINGS. 0 NOT APPLICABLE WHERE Y = 4'-0". DIAMETER OF PIPE AND MINIMUM "X" IN THIS INLET DATA TABLE ARE BASED ON THE LONGITUDINAL PIPE. DEPTH OF THE INLET MAY BE GOVERNED BY THE TRANSVERSE PIPE (MINIMUM "D" = TRANSVERSE PIPE DIAMETER PLUS 9"). TRANSVERSE PIPE TYPICAL SECTION OF INLETS * GROUT SHALL BE FINISHED SUCH THAT THE TOP ELEVATION OF THE INLET LID, WHEN INSTALLED, MATCHES THE FINISHED SHOULDER SLOPE OF THE ROADWAY CROSS-SECTIONS. NOTES: THE MINIMUM COVERING, MEASURED FROM THE FACE OF CONCRETE TO THE SURFACE OF ANY REINFORCING BAR, SHALL BE 1%". THE QUANTITIES OF CONCRETE AND STEEL FOR CURB INLET INCLUDES THAT PORTION OF CONCRETE AND STEEL BELOW AND BACK OF THE CURB SECTION AS SHOWN ON THIS PLAN. THE CONCRETE COVERS MAY BE CAST IN PLACE OR PRECAST. THE CAST IRON COVERS, FRAMES SHALL BE GREY IRON CONFORMING TO THE SPECIFICATIONS. CAST IRON STEPS SHALL BE INSTALLED IN CURB INLETS AND JUNCTION BOXES WHEN THE "X" DIMENSION IS 4 -6 OR GREATER. THE FURNISHING AND PLACING OF CAST IRON STEPS SHALL BE SUBSIDIARY TO THE ITEM FOR WHICH DIRECT PAYMENT IS MADE. THE GUTTER DEPRESSION TEMPLATE SHALL BE USED THROUGHOUT THE THROAT OPENING. CLASS OF CONCRETE AND MINIMUM COMPRESSIVE STRENGTH AND TYPE OF STEEL FOR REINFORCING BARS SHALL CONFORM TO THE DEPARTMENT OF ROADS "STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION." THE INLET COVER SHALL BE IMPRINTED "NO DUMPING" SEE SHEET 2 OF 2. 8" THICK CONCRETE WALL LOCATED AT MID -POINT (Y/2) OF INLET OPENING. I "r 2 -BAR K 81, 1'-01, 8' 2 BAR J SECTION FOR 14'-0", 16'-0" & 18'-0" INLET OPENINGS MID --POINT COVER SUPPORT R9 APR 14 PUT Y1-2" BACK IN JUNCTION BOX R8 JUL 11 FACE ARMOR DETAIL R7 JAN 07 NO DUMPING, DRAINS TO STREAM REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 443-R9 CURB INLETS AND JUNCTION BOX ACCEPTED BY FHWA FOR USE ON NATIONA HIGHWAY SYST DATA FOR CURB INLETS DIA. DIMENSIONS QUANTITIES NO. OF M BARS ADDITIONAL QUANTITIES PER ONE FOOT INCREASE OF DIMENSION X LONGIT. PIPE X0 (MIN.) AO B C D CONCRETE, CU. YDS. ® REINFORCING STEEL, LBS. CONCRETE CU. YDS. REINF. STEEL LBS. .® Y=4' Y=6' Y=8' Y=101 Y=12' Y=14' Y=16' Y=181 Y=4' Y=6' Y=8' Y=10' Y=12' Y=14' Y=16' Y=18' -- 31-11" 2'-8" -- 2'-8" 2'-0" 2.08 2.43 2.79 3.15 3.51 4.06 4.46 4.85 113 175 202 231 259 289 316 344 NONE 0.383 6.7 12 II 1 11 2 -11 1 11 4 -0 I 11 1 -7 1 i1 1 -8 1 11 1 -0 2.14 2.51 2.86 3.21 3.56 3.95 4.30 4.65 133 186 216 245 274 310 340 364 3 0.459 6.7 15" 3'-2" 4'-3" 1'-11" 1'-11" 1'-3" 2.37 2.71 3.07 3.43 3.79 4.21 4.57 4.94 136 193 221 250 277 312 342 370 3 0.473 6.7 18 It 1 11 3 -5 1 11 4 -7 I " 2 -2 I II 2 -2 1 11 1 -6 2.60 2.95 3.30. 3.67 4.03 4.44 4.80 5.16 141 200 228 257 284 318 349 376 4 0.490 6.7 21" 3" 41 it 11 2 1-6 " 1-511 2 1 1-9Ii 2.83 3.19 3.53 3.90 4.26 4.68 5.04 5.40 144 203 231 260 287 322 351 379 4 0.504 6.7 2411 311-8 11 11 � 5-211 21-9 11 2'-8" 21-011 3.06 3.41 3.76; 4.12. 4.49 5.04 5.43 5.83 148 210 238 267 294 324 352 379 5 0.518 6.7 2711 4'-2" 51-6" 31-1" 21 -1111 2'-3" 3.31 3.66 4.01 4.37 4.74 5.29 5.68 6.08 150 213 241 270 297 327 354 382 5 0.532 6.7 30" 1 " 4 -5 1 it 5 -9 1 it 3 -4 I II 3 -2 1 Ii 2 -6 3.54 3.89 4.25 4.61 4.97 5.52 5.92 6.32 151 217 244 273 301 331 358 385 5 0.547 6.7 3611" 4'-11" 61-4 3i II 11 1-81t 3 3 1-0II 4.06 4.41 4.77`:: 5.13 5.49 6.04 6.44. 6.83 158 _ 226 254 283 310 340 368 395 6 0.576 6.7 4211 51-5" 61-11" � 41-6" 41-2" 31. -6t1 4.60 4.95 5.31:1 5.67 6.03 6.58 6.98 7.38 164 236 264 293 320 350 378 405 7 0.605 6.7 48" 1 11 5 -11 i II 7 -6 I II 5 -1 1 " 4 -8 1 II 4 -0 5.18 5.53 5.89 6.25 6.61 7.16 7.56 7.95 171 246 274 303 330 360 387 415 8 0.634 6.7 54" 6'-5" 8'-1" 5'-8" 5'-2" 41-6" 5.78 6.13 6.49 6.85 7.21 7.76 8.16 8.56 174 253 280 309 337 367 394 421 8 0.663 6.7 60" 6'-11" 8'-8" 6'-3" 5'-8" 5'-0" 6.41 6.76 7.12:.. 7.48 7.84 8.39 8.79 9.19 180 262 290 319 346 376 404 431 9 0.691 6.7 66" 7'-5" 9'-3" 6'-10" 6'-2" 5'-6" 7.07 7.42 7.78:;.8.14 8.50 9.05 9.45 9.85 187 272 _ 300 329 356 386 414 _ 441 10 0.720 6.7 LOCATION OF BACK WALL WHEN LONGITUDINAL PIPES ARE NOT USED B m 1" NON SHRINK BEDDING GROUT 0 "X" SHALL NOT EXCEED 7'-6". 2Q "A" SHALL NOT EXCEED 10'-0". 0 NO DEDUCTIONS WILL BE MADE FOR PIPE OPENINGS. 0 NOT APPLICABLE WHERE Y = 4'-0". DIAMETER OF PIPE AND MINIMUM "X" IN THIS INLET DATA TABLE ARE BASED ON THE LONGITUDINAL PIPE. DEPTH OF THE INLET MAY BE GOVERNED BY THE TRANSVERSE PIPE (MINIMUM "D" = TRANSVERSE PIPE DIAMETER PLUS 9"). TRANSVERSE PIPE TYPICAL SECTION OF INLETS * GROUT SHALL BE FINISHED SUCH THAT THE TOP ELEVATION OF THE INLET LID, WHEN INSTALLED, MATCHES THE FINISHED SHOULDER SLOPE OF THE ROADWAY CROSS-SECTIONS. NOTES: THE MINIMUM COVERING, MEASURED FROM THE FACE OF CONCRETE TO THE SURFACE OF ANY REINFORCING BAR, SHALL BE 1%". THE QUANTITIES OF CONCRETE AND STEEL FOR CURB INLET INCLUDES THAT PORTION OF CONCRETE AND STEEL BELOW AND BACK OF THE CURB SECTION AS SHOWN ON THIS PLAN. THE CONCRETE COVERS MAY BE CAST IN PLACE OR PRECAST. THE CAST IRON COVERS, FRAMES SHALL BE GREY IRON CONFORMING TO THE SPECIFICATIONS. CAST IRON STEPS SHALL BE INSTALLED IN CURB INLETS AND JUNCTION BOXES WHEN THE "X" DIMENSION IS 4 -6 OR GREATER. THE FURNISHING AND PLACING OF CAST IRON STEPS SHALL BE SUBSIDIARY TO THE ITEM FOR WHICH DIRECT PAYMENT IS MADE. THE GUTTER DEPRESSION TEMPLATE SHALL BE USED THROUGHOUT THE THROAT OPENING. CLASS OF CONCRETE AND MINIMUM COMPRESSIVE STRENGTH AND TYPE OF STEEL FOR REINFORCING BARS SHALL CONFORM TO THE DEPARTMENT OF ROADS "STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION." THE INLET COVER SHALL BE IMPRINTED "NO DUMPING" SEE SHEET 2 OF 2. 8" THICK CONCRETE WALL LOCATED AT MID -POINT (Y/2) OF INLET OPENING. I "r 2 -BAR K 81, 1'-01, 8' 2 BAR J SECTION FOR 14'-0", 16'-0" & 18'-0" INLET OPENINGS MID --POINT COVER SUPPORT R9 APR 14 PUT Y1-2" BACK IN JUNCTION BOX R8 JUL 11 FACE ARMOR DETAIL R7 JAN 07 NO DUMPING, DRAINS TO STREAM REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 443-R9 CURB INLETS AND JUNCTION BOX ACCEPTED BY FHWA FOR USE ON NATIONA HIGHWAY SYST ROADWAY DESIGN DIVISION Computer: DRDESIGN173 User: dor13182 Date: 28 -OCT -2013 09:06 N 04 N INLET COVER QUANTITIES FOR JUNCTION BOX SIZE Y x Y 1 X = 2'-6" ADDITIONAL QUANTITIES OF CONCRETE (CU. YDS.) PER ONE FOOT INCREASE OF DIMENSIONS "X" ** CONCRETE CU. YDS. * REINFORC. STEEL LBS. 2'-0" x 2'-0" 0.94 15 0.26 V-0" x 2'-6" 1.06 18 0.27 2'-0" x 3'-O" 1.18 23 0.31 2'-6" x 2'-6" 1.20 19 0.31 2'-6" x 3'-O" 1.33 22 0.34 3'-0" x 3'-0" 1.47 29 0.36 3'-0" x . 3'-6" 1.61 30 0.39 3'-0" x 4'-0" 1.76 34 0.41 * NO DEDUCTIONS WILL BE MADE FOR PIPE OPENINGS ** DIMENSION "X" SHALL NOT EXCEED 5'-6" NO. 4 BARS AT 8" MAX. SPACING - N0. 4 BARS ATS" MAX. SPACING rt "Iw 1 ;' I 1> :.tk:. 1 irr ! , I I I*----4-21 I -----I—Y--I---F 9" Y7+11-4" PLAN Y-2" OR Y1-2" r 'I t 4" MAX. • 2'-O" kit �30' MAX. 16" (TYP.) co 1_8" Y OR Y1 'I SECTION C -C JUNCTION BOX (NOT FOR USE UNDER TRAFFIC) 3" NO DUMPING, T DRAINS TO STREAM NOTE: TEXT IS TO BE IMPRINTED INTO CONCRETE, AT A DEPTH OF %". 60" 6 SECTION CQ BAR N AT 83/4" CTRS.aJ 5,-4" BACK COVER PLAN THE CAST IRON COVERS AND FRAMES SHALL BE GREY IRON CONFORMING TO THE SPECIFICATIONS. ...0 a P1 11H )01►1/ 144 NgiOr 3" 11 HA TCHED1 SURFACE\ 2'-O" PICK HOLE (OPTIONAL) f t t 39" 21" 1'-11" TOTAL WEIGHT = 125 LBS. 1" CAST IRON COVER AND FRAME PAVING CROSS 0.01 0.02 0.03 0.04 0.05 0.06 SLOPE (FT/FT) 157 10'-0" 186 12'-0" 215 14'-0" H 10°/,s" 101A" 10%6" 97/8" 9%" 9T/s" GUTTER DEPRESSION TEMPLATE LIFT BAR GROUT COVER ti A NO. 4 ANCHOR BAR - (ANCHOR BAR SHALL BE PLACED IN %" MAX. DRILLED HOLE AND SET WITH EPDXY COMPOUND) SECTION A -A A PLAN ANCHOR BAR. SECTION B -B PLAN t/n \Tr' CHAMFER DETAIL lo" t` r1 E FRONT ELEVATION STEPS TO BE PLACED AT 16" CENTERS CAST IRON STEPS GRIND UPPER CORNER OPTIONAL .(SEE CHAMFER DETAIL) STRUCTURAL STEEL FOR FACE ARMOR THROAT OPENING WEIGHT (LBS.) 4'-0" 100 6I-0" 129 8'-0" 157 10'-0" 186 12'-0" 215 14'-0" 243 16'-0" 272 C6X13 - FULL LENGTH OF INLET COVER 1N" (TYP.) RADIUS ALTERNATE OR CHAMFER NOTE: FACE ARMOR NO. 4 DEFORMED ANCHOR BAR AT 9" CENTER THE COMPLETED FACE ARMOR/ANCHOR BAR ASSEMBLY SHALL BE HOT -DIP GALVANIZED IN ACCORDANCE WITH ASTM A153. R9 R8 R7 APR 14 JUL 11 JAN 07 PUT Y1-2" BACK IN JUNCTION BOX FACE ARMOR DETAIL NO DUMPING, .DRAINS TO STREAM REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 443-R9 CURB INLETS AND JUNCTION BOX ACCEPTED BY FHWA FOR USE NATIONAL HIGHWAY SYST ORIGINAL: FEBRUARY 22, 1974 DATE ROADWAY DESIGN DIVISION Computer: DRDESIGN173 User: dor13182 Date: 28-0CT-2013 09:06 c 0> 0 0 0 N 0 - En 0 O 0 00 N •• 0 N U7 NLL 4.-0 O 0 Lil I 6'-0" MINIMUM I OVERLAP 1 I 1 SILT FENCE SPLICE SILT FENCE BAY , , , , T SILT FENCE WITH O' -D" RADIUS BAY BAY DETAIL F F 2'-0" MIN. F NOTE: SILT FENCE AT CORNERS SHALL HAVE A RADIUS OF O'-0" MINIMUM TO 10'-0" MAXIMUM 6'-0" STEEL • POST Nm TOE OF SLOPE TRENCH AND COMPACT BACKFILL SEE TRENCH DETAIL OPTION ONE (PREFERED) SILT FENCE (6`-0" OFFSET FROM TOE OF FILL) Nm TRENCH AND COMPACT BACKFILL SEE TRENCH DETAIL STEEL POST TOE OF SLOPE OPTION TWO (WITH LIMITED R.O.W. ) SILT FENCE (AT TOE OF FILL) 6'-0" OFFSET FROM —� TOE OF FILL (MINIMUM) SILT FENCE TIRE COMPACTION ZONE FLOW MACHINE SLICE 8" TO 12" DEPTH FLOW SILT FENCE BAYS STEEL POST PLASTIC ZIP TIES (50 LB TENSILE) LOCATED ON TOP 8" SILT FENCE MACHINE SLICED STEEL POST 2'-0" SILT TRAP 6,_0„ 2'-0" 2'-0" APPROX. TRENCH AND COMPACT BACKFILL SEE TRENCH DETAIL HIGH POROSITY SILT FENCE WITH SILT TRAP (ACROSS DITCH) FABRIC HIGH POROSITY SILT FENCE (ACROSS DITCH) NOTE: POST SPACING 6'-0" MAXIMUM MULTIPLE BAYS MAY BE USED STEEL POST PLASTIC CABLE TIES PROFILE VIEW ATTACHMENT TO POST FLOW,,, TRENCH AND COMPACT BACKFILL SEE TRENCH DETAIL STEEL POST STEEL POST PLASTIC CABLE TIES BACK VIEW ATTACHMENT TO POST HIGH POROSITY LOW POROSITY 8'-0" MAX.. 3'-O" MIN. SILT FENCE (ACROSS DITCH) SILT FENCE 0 X /} X // SILT FENCE �f (UNDER BRIDGE) ***6" x 1" WIRE STAPLE PLACED AT P-0" ON CENTER TRENCH DETAIL * * * SILT FENCE MAY ALSO BE INSTALLED WITH A SILT FENCE PLOW. NO STAPLING IS REQUIRED WHEN THE SILT FENCE PLOW IS USED. NOTES: SILT FENCE SHOULD BE 30" ABOVE GRADE (MAY VARY) SILT FENCE MINIMUM ROLL WIDTH: LOW POROSITY = 42" HIGH POROSITY = 42" LOW PROFILE = 36" COIR SILT FENCE = 36" STEEL STUDDED "T" LINE POSTS 5'-6" LENGTH; 6'-0" MAXIMUM SPACING. FOR EACH STEEL STUDDED "T" LINE POST, 3 PLASTIC CABLE TIES ARE REQUIRED. 2" x 2" x 6'-O" NOMINAL WOOD STAKES SPACING, 6'-O" MAXIMUM ON CENTER DRIVEN UNTIL FIRM. R1 APR 14 STEEL POST INSTALLATION REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 502-R1 SILT FENCE DETAILS ACCEPTED BY FHWA FOR USE NATIONAL HIGHWAY SYSTE ATE ORIGINAL: DECEMBER 18, 2006 DATE ROADWAY DESIGN DIVISION DRDESIGN173 C) 4- a E C) User: dor13182 Date: 28 -OCT -2013 09:06 EROSION CONTROL LOW POROSITY I BLANKET ' SILT FENCE FLOW 61-0" MIN. X — X TOE OF SLOPE (TYP.) X I X TOE OF SLOPE SILT FENCE OUTLET PROTECTION NOTES: 1. SILT FENCE SHOULD BE BROUGHT FLUSH WITH WING WALLS ON BOX CULVERTS IF IT CAN NOT BE INSTALLED ABOVE THE BOX CULVERT. 2. IF APPLICABLE, SILT FENCE AROUND THE CULVERT SHOULD BE ADJUSTED TO ALLOW FOR THE INSTALLATION OF EROSION CONTROL AS SHOWN IN STANDARD PLAN 501. 3. SILT CHECKS MAY USED IN PLACE OF SILT FENCE ABOVE THE OPENING OF A CUL VERT, AS SHOWN IN SPECIAL PLAN C. HIGH POROSITY SILT FENCE 0 (1.) 0 c 0 L\J V 0 Ln 0 W 0 0 0 0 (\Jfl 0 r" IS) nu_ (DO a; oc.3 is 1— Ui Ui TOE OF SLOPE n XX XX FLOW I 1 I o x ),----- XX XX —,L XXc\i I - 6'-0" 121-0" (TYP.) TOE OF SLOPE SILT FENCE INLET PROTECTION PLASTIC CABLE TIES - IF STAPLES ARE USED THEY MUST BE THROUGH ALL LAYERS OF FABRIC SILT FENCE FABRIC WATER LEVEL VARIES SILT RUNOFF WOOD STAKE 6" 6" x 1" WIRE STAPLE EVERY 2'-0" NOTE: * INCLINE STAKE 15° TO 20° MAX. FROM VERTICAL, TOWARD FLOW. FLOW "sr SILT FENCE (WET & BELOW WATER INSTALLATION) 36" COIR SILT FENCE FABRIC 1 Pr) BACKFILL PLASTIC CABLE TIES - (STAPLED TO POST) IF STAPLES ARE USED THEY MUST BE THROUGH ALL LAYERS (3 -REQUIRED ON EACH STAKE) WOOD STAKE co a0,\ 2 r .\\ • //\ / \, \A 4 — 6" x 1" WIRE STAPLE —1. - COIR SILT FENCE - ON WOOD POSTS - DRY INSTALLATION STEEL STUDDED "T" LINE POSTS 51-6" LENGTH XX XX HIGH POROSITY SILT FENCE XX tX XX XX LOW POROSITY — x )/.1 --- X SILT FENCE X X r ><.c(TYP. ) 1 ANY r, GRATE 1 x L IT—X—X—IX— X L2 XX XX XX —IXX XX XX LI& L2 = OUTSIDE OF WALL + 41-0" PLAN VIEW x x 4 XXJ SILT FENCE FOR GRATE, AREA, MEDIAN INLETS OR JUNCTION BOXES *3'-O" IF POSSIBLE (MAY VARY) STEEL STUDDED "T" LINE POSTS 5'-6" LENGTH x L. X X LOW POROSITY SILT FENCE x-rc Y X X — X --3E L2 L7= A + 61-0" L2= Y 61-0" PLAN VIEW SILT FENCE CURB INLET R1 APR 14 STEEL POST INSTALLATION REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 502-131. SILT FENCE DETAILS ACCEPTED BY FHWA FOR U NATIONAL HIGHWAY SYST DATE ORIGINAL: DECEMBER 18, 2006 DATE ROADWAY DESIGN DIVISION U 0 N 0 0 0 0 L 0 } a 0 U User: dor1301 27 -FEB -2014 07:45 m 0 0 c . 0 a td 0 00 00 0^ rn CHANNELIZATION DEVICES THE FUNCTION OF CHANNELIZATION DEVICES IS TO WARN ROAD USERS OF :CONDITIONS CREATED BY WORK ACTIVITIES IN OR NEAR THE TRAVELED WAY, TO PROTECT WORKERS IN THE TEMPORARY TRAFFIC CONTROL ZONE, AND TO GUIDE DRIVERS AND PEDESTRIANS SAFELY... CHANNELIZING DEVICES INCLUDE BUT ARE NOT LIMITED TO CONES, TUBULAR POSTS, VERTICAL PANELS, DRUMS, BARRICADES, TRAFFIC LANE DIVIDERS, TEMPORARY RAISED ISLANDS, AND BARRIERS. DEVICES USED FOR CHANNELIZATION SHOULD PROVIDE FOR SMOOTH AND GRADUAL TRAFFIC MOVEMENT FROM ONE LANE TO ANOTHER, ONTO A BYPASS OR DETOUR, OR TO REDUCE THE WIDTH OF THE TRAVELED WAY. THEY MAY ALSO BE USED TO SEPARATE TRAFFIC ;FROM THE WORK SPACE, PAVEMENT DROP-OFFS, PEDESTRIAN PATHS, OR OPPOSING DIRECTIONS OF TRAFFIC. CHANNELIZING DEVICES SHALL MEET THE CRASHWORTHY PERFORMANCE CRITERIA CONTAINED IN THE NATIONAL COOPERATIVE HIGHWAY RESEARCH PROGRAM (NCHRP) REPORT 350 OR MANUAL FOR ASSESSING SAFETY HARDWARE (MASH). THEY SHOULD BE CONSTRUCTED AND BALLASTED TO PERFORM IN A PREDICTABLE MANNER WHEN INADVERTENTLY STRUCK BY A :VEHICLE. IF STRUCK, THE DEVICE SHOULD YIELD OR BREAK AWAY, FRAGMENTS OR OTHER DEBRIS FROM THE DEVICE SHOULD NOT PENETRATE THE PASSENGER COMPARTMENT OF THE VEHICLE OR BE A POTENTIAL HAZARD TO WORKERS OR PEDESTRIANS IN THE IMMEDIATE AREA. SPACING OF CHANNELIZING DEVICES SHOULD NOT EXCEED A DISTANCE IN FEET EQUAL TO THE SPEED WHEN USED FOR THE TAPER CHANNELIZATION, AND A DISTANCE IN FEET OF TWICE THE SPEED WHEN USED FOR TANGENT CHANNELIZATION. SPACING OF CHANNELIZATION DEVICES SPEED (MPH) S SPACING OF DEVICES (FEET) TAPER _. TANGENT 25 25 50 35 35 70 45 45 . 90 55 55 110 60 60 120 65 65 130 75 75 150 WARNING LIGHTS MAY BE ADDED TO CHANNELIZING DEVICES IN AREAS WITH FREQUENT FOG, SNOW, OR SEVERE ROADWAY CURVATURE, OR WHERE VISUAL DISTRACTIONS ARE PRESENT, EXCEPT FOR THE SEQUENTIAL FLASHING WARNING LIGHTS, WARNING LIGHTS PLACED ON "CHANNELIZING DEVICES USED IN A SERIES TO CHANNELIZE ROAD USERS SHALL BE STEADY -BURN. . THE RETROREFLECTIVE MATERIAL USED ON CHANNELIZING DEVICES SHALL'. HAVE A SMOOTH, SEALED OUTER SURFACE, MEETING THE REQUIREMENTS OF THE ASTM SPECIFICATION D4956, FOR TYPE IV SHEETING OR TYPE V REBOUNDABLE SHEETING (OR GREATER). COEFFICIENT OF RETROREFLECTION` (CD/LUX/M2) WHITE ORANGE RED YELLOW• 250 100 45 170 THE AMERICAN TRAFFIC SAFETY SERVICES ASSOCIATION (ATSSA) "QUALITY GUIDELINES FOR WORK ZONE TRAFFIC CONTROL DEVICES" SHALL BE USED AS A VISUAL GUIDE FOR DETERMINING IF A TRAFFIC CONTROL DEVICE/OR SIGN IS ACCEPTABLE, MARGINAL OR UNACCEPTABLE. THE NAME AND TELEPHONE NUMBER OF THE AGENCY, CONTRACTOR, OR SUPPLIER MAY BE SHOWN ON THE CHANNELIZING DEVICE BACK OR SUPPORT, BUT NOT ON THE DEVICE FACE. THE LETTERS AND NUMBERS SHALL BE A NON -REFLECTIVE COLOR AND NOT OVER 15 SQUARE INCHES IN TOTAL AREA. PARTICULAR ATTENTION SHOULD BE GIVEN TO MAINTAINING THE CHANNELIZING DEVICES TO KEEP THEM CLEAN, VISIBLE, AND PROPERLY POSITIONED. DEVICES SHALL BE REPLACED THAT ARE DAMAGED AND/OR HAVE LOST A SIGNIFICANT AMOUNT OF THEIR RETROREFLECTIVITY AND EFFECTIVENESS. REFLECTORIZED PLASTIC DRUMS RETROREFLECTIVE WHITE RETROREFLECTIVE WHITE DESIGN RETROREFLECTIVE FLUORESCENT ORANGE OPTIONALtRETROREFLECTIVE FLUORESCENT ORANGE REFLECTORIZED PLASTIC DRUMS USED FOR TRAFFIC WARNING OR CHANNELIZATION SHALL BE CONSTRUCTED OF LIGHTWEIGHT, FLEXIBLE, AND DEFORMABLE MATERIALS AND BE A MINIMUM OF 36 INCHES IN HEIGHT AND HAVE A MINIMUM WIDTH OF AT LEAST A 18 INCHES, REGARDLESS OF ORIENTATION. THE PREDOMINANT COLOR OF THE DRUM SHALL BE ORANGE. METAL DRUMS SHALL NOT BE USED. THE MARKINGS ON DRUMS SHALL BE HORIZONTAL, SHALL BE CIRCUMFERENTIAL, AND SHALL DISPLAY FOUR 6 INCH WIDE BANDS OF RETROREFLECTIVE SHEETING, ALTERNATING FLUORESCENT ORANGE -WHITE -FLUORESCENT ORANGE -WHITE, DRUMS SHALL HAVE CLOSED TOPS THAT WILL NOT ALLOW COLLECTION OF CONSTRUCTION OR OTHER DEBRIS.: APPLICATION DRUMS ARE MOST COMMONLY USED TO CHANNELIZE OR DELINEATE TRAFFIC FLOW BUT MAY ALSO BE USED INDIVIDUALLY OR IN GROUPS TO MARK SPECIFIC LOCATIONS. DRUMS ARE HIGHLY VISIBLE AND HAVE GOOD TARGET VALUE; THEY GIVE THE APPEARANCE OF BEING FORMIDABLE OBSTACLES AND, THEREFORE, COMMAND THE RESPECT OF ROAD USERS. BALLAST SHALL NOT BE PLACED ON TOP OF THE DRUM. DRUMS SHOULD NOT BE WEIGHTED WITH SAND, WATER, OR ANY MATERIAL. BARRICADES BARRICADE TYPE TYPE II TYPE III WIDTH OF RAIL*.8 INCHES MIN. - 12 INCHES MAX. .. 8 INCHES MIN. - 12 INCHES MAX. LENGTH OF RAIL 36 INCHES 8 FEET** WIDTH OF STRIPES 6 INCHES 6 INCHES HEIGHT 36 INCHES 5 FEET REFLECTIVE SHEETING TYPE IV TYPE IV NUMBER OF REFLECTORIZED RAIL FACES 4 (TWO EACH DIRECTION) 6 (THREE EACH DIRECTION) *NOMINAL DIMENSIONS ARE PERMISSIBLE WHEN CONSTRUCTED FROM LUMBER. **WHEN LATERAL SPACE IS LIMITED, SOME TYPE III BARRICADES WITH A 4 FOOT LENGTH OF RAIL, MAY BE ALLOWED WHEN APPROVED BY THE ENGINEER. TYPE III BARRICADE TYPICAL MOUNTING OF FLASHING WARNING LIGHTS. LIGHTS SHALL ALWAYS BE IN VERTICAL ALIGNMENT. TYPE II BARRICADE I+ BALLAST BAR BALLAST TIE CHAIN OR OTHER APPROVED METHOD BALLAST SHALL NOT BE PLACED OVER ANY REFLECTIVE DEVICE DESIGN A BARRICADE IS A PORTABLE OR FIXED DEVICE HAVING TWO OR THREE RAILS WITH APPROPRIATE MARKINGS. IT IS USED TO CONTROL ROAD USERS BY CLOSING, RESTRICTING, OR DELINEATING ALL OR A PORTION OF THE RIGHT-OF-WAY. BARRICADES SHALL BE ONE OF TWO TYPES; TYPE II OR TYPE III. STRIPES ON BARRICADE RAILS SHALL BE ALTERNATING ORANGE AND WHITE RETROREFLECTIVE STRIPES SLOPING DOWNWARD AT AN ANGLE OF 45 DEGREES IN THE DIRECTION ROAD USERS ARE TO PASS. THE STRIPES SHALL BE 6 INCHES WIDE. THE MINIMUM RAIL LENGTH FOR A TYPE II BARRICADE IS 36 INCHES. WHERE BARRICADES EXTEND ENTIRELY ACROSS A ROADWAY, THE STRIPES SHOULD SLOPE DOWNWARD IN THE DIRECTION TOWARD WHICH ROAD USERS MUST TURN. WHERE BOTH RIGHT AND LEFT TURNS ARE PROVIDED, THE STRIPES MAY SLOPE DOWNWARD IN BOTH DIRECTIONS FROM THE CENTER OF THE BARRICADE OR BARRICADES. WHERE NO TURNS ARE INTENDED, THE STRIPES SHOULD SLOPE DOWNWARD TOWARD THE CENTER OF THE BARRICADE OR BARRICADES. BARRICADE RAILS SHOULD BE SUPPORTED IN A MANNER THAT WILL ALLOW THEM TO BE SEEN BY THE ROAD USER, AND IN A MANNER THAT PROVIDES A STABLE SUPPORT THAT IS NOT EASILY BLOWN OVER OR DISPLACED. ON HIGH-SPEED ROADWAYS OR IN OTHER SITUATIONS WHERE BARRICADES MAY BE SUSCEPTIBLE TO OVERTURNING IN THE WIND, SANDBAGS SHOULD BE USED FOR BALLASTING. SANDBAGS MAY BE PLACED ON LOWER PARTS OF THE FRAME OR STAYS TO PROVIDE THE REQUIRED BALLAST BUT SHALL NOT BE PLACED ON TOP OF ANY STRIPED RAIL. BARRICADES SHALL NOT BE BALLASTED BY HEAVY OBJECTS SUCH AS ROCKS OR CHUNKS OF CONCRETE. THE BARRICADE OWNERS NAME, NOT TO EXCEED 15 SQUARE INCHES SHALL BE SHOWN ON THE BARRICADE BACK OR SUPPORT BUT NOT ON ITS FACE. ** WHEN LATERAL SPACE IS LIMITED, SOME TYPE III BARRICADES WITH A 4 FOOT LENGTH OF RAIL, MAY BE ALLOWED WHEN APPROVED BY THE ENGINEER. APPLICATION TYPE II BARRICADES ARE INTENDED FOR USE IN SITUATIONS WHERE TRAFFIC IS MAINTAINED THROUGH THE TEMPORARY TRAFFIC CONTROL ZONE. THEY MAY BE USED INDIVIDUALLY OR IN GROUPS TO MARK A SPECIFIC CONDITION, OR THEY MAY BE USED IN A SERIES FOR CHANNELIZING TRAFFIC. ON THE INTERSTATE, FREEWAY AND EXPRESSWAY SYSTEM, TYPE II BARRICADES SHALL NOT BE USED FOR CHANNELIZATION. TYPE III BARRICADES USED AT A ROAD CLOSURE MAY EXTEND COMPLETELY ACROSS A ROADWAY FROM CURB TO CURB. WHERE PROVISION IS MADE FOR ACCESS OF AUTHORIZED EQUIPMENT AND VEHICLES, THE RESPONSIBILITY FOR THE TYPE III BARRICADES SHOULD BE ASSIGNED TO A PERSON WHO SHALL PROVIDE PROPER CLOSURE AT THE END OF EACH WORK DAY. WHEN A HIGHWAY IS LEGALLY CLOSED BUT ACCESS MUST STILL BE ALLOWED FOR LOCAL TRAFFIC, THE TYPE III BARRICADES MAY NOT BE EXTENDED COMPLETELY ACROSS A ROADWAY. A SIGN WITH THE APPROPRIATE LEGEND CONCERNING PERMISSIBLE USE BY LOCAL TRAFFIC SHALL BE MOUNTED. NORMALLY PERMANENT SIGNS MOUNTED ON BARRICADES SHALL BE ERECTED ABOVE THE BARRICADE. THE SIGNS "ROAD CLOSED", OR "ROAD WORK AHEAD", FOR EXAMPLE CAN EFFECTIVELY BE MOUNTED ABOVE THE BARRICADE THAT CLOSES THE ROADWAY. TYPE III BARRICADES SHALL BE SUPPLEMENTED WITH A LIGHTING DEVICE UNLESS SPECIFICALLY OMITTED BY THE ENGINEER. DETOUR ARROW AND LARGE WARNING ARROW SIGNS SHOULD BE PLACED ON THE FACE OF BARRICADE. CONES RETROREFLECTIVEli WHITE DESIGN CONES SHALL BE PREDOMINANTLY ORANGE, FLOURESCENT RED -ORANGE, OR FLOURESCENT YELLOW/ORANGE, NOT LESS THAN 28 INCHES IN HEIGHT, AND SHALL BE MADE OF A MATERIAL THAT CAN BE STRUCK WITHOUT DAMAGING VEHICLES ON IMPACT. CONES WHEN ALLOWED ON THE INTERSTATE, FREEWAY OR EXPRESSWAY SYSTEM SHALL BE A MINIMUM OF 36 INCHES IN HEIGHT. FOR NIGHTTIME USE, CONES SHALL BE RETROREFLECTIVE OR EQUIPPED WITH LIGHTING DEVICES FOR MAXIMUM .VISIBILITY. RETROREFLECTION OF 28 INCH OR 36 INCH CONES SHALL BE PROVIDED BY A WHITE BAND 6 INCHES WIDE, NO MORE THAN 4 INCHES FROM THE TOP OF THE CONE, AND AN ADDITIONAL 4 INCH WIDE WHITE BAND A MINIMUM OF 2 INCHES BELOW THE 6 INCH BAND. APPLICATION TRAFFIC CONES ARE USED TO CHANNELIZE TRAFFIC, DIVIDE OPPOSING TRAFFIC LANES, DIVIDE TRAFFIC LANES WHEN TWO OR MORE LANES ARE KEPT OPEN IN THE SAME DIRECTION, AND DELINEATE SHORT -DURATION MAINTENANCE AND UTILITY WORK. CONES SHALL NOT BE USED FOR LANE CLOSURE TAPERS OR SHIFTS, CONES SMALLER THAN 42 INCHES SHALL NOT BE USED AT NIGHT ON RURAL HIGHWAYS, UNLESS SHOWN ON THE PLANS OR AS APPROVED OR DIRECTED BY THE ENGINEER. STEPS SHOULD BE TAKEN TO ENSURE THAT CONES WILL NOT BE BLOWN OVER OR DISPLACED BY WIND OR MOVING TRAFFIC. CONES CAN BE DOUBLED UP TO INCREASE THEIR WEIGHT. SOME CONES ARE CONSTRUCTED WITH BASES THAT CAN BE FILLED WITH BALLAST. OTHERS HAVE SPECIAL WEIGHTED BASES. OR WEIGHTS SUCH AS SANDBAG RINGS THAT CAN BE DROPPED OVER THE CONES AND ONTO THE BASE TO PROVIDE ADDED STABILITY. BALLAST, HOWEVER, SHOULD NOT PRESENT A HAZARD IF THE CONES ARE INADVERTENTLY STRUCK. 42 INCH CONES RETROREFLECTIVE FLUORESCENT ORANGE RETROREFLECTIVE WHITE 30 LB BASE 2%/4' MAX. HEIGHT DESIGN 42 INCH CONES SHALL INCLUDE A 30 POUND RUBBER BASE AND DISPLAY FOUR 6 INCH WIDE BANDS OF RETROFEFLECTIVE SHEETING, ALTERNATING FLUORESCENT ORANGE-WHITE- FLOURESCENT ORANGE -WHITE. APPLICATION . WHEN APPROVED BY THE ENGINEER OR SHOWN IN THE PLANS, 42 INCH REFLECTIVE CONES MAY BE USED IN LIEU OF TYPE II BARRICADES OR REFLECTORIZED DRUMS. 42 INCH CONES SHALL NOT BE USED FOR LANE -CLOSURE TAPERS OR SHIFTS. IF A RECTANGULAR BASE IS USED, THE LONG SIDE OF THE BASE SHOULD BE ORIENTED PARALLEL TO THE DIRECTION OF TRAFFIC. TUBULAR POST AND CURB SYSTEM RETROREFLECTIVE BANDS 36" - 42" '1 CURB UNIT 2" 4" DESIGN TUBULAR POSTS USED IN THE SYSTEM SHALL BE 36 INCHES HIGH AND A MINIMUM OF 2 INCHES WIDE WHEN FACING TRAFFIC. THE TUBULAR POST AND CURB SYSTEM SHALL BE MADE OF A MATERIAL THAT CAN BE STRUCK WITHOUT DAMAGING IMPACTING VEHICLES. THE COLOR SHALL BE AS SHOWN IN THE PLANS. THE TUBULAR POSTS SHALL BE RETROREFLECTIVE. RETROREFLECTION OF TUBULAR POSTS SHALL BE PROVIDED BY TWO 3 -INCH WIDE RETROREFLECTIVE BANDS PLACED A MAXIMUM OF 2 INCHES FROM THE TOP WITH A MAXIMUM OF 6 INCHES BETWEEN THE BANDS. EACH CURB SECTION SHALL CONTAIN ONE RETROREFLECTIVE MARKER FACING EACH DIRECTION OF TRAFFIC. THE COLOR OF THE RETROREFLECTIVE BANDS AND MARKERS SHALL MATCH THE POST/CURB COLOR. THE CURB SECTIONS SHALL BE CONFIGURED TO ALLOW FOR DRAINAGE FROM THE PAVEMENT SURFACE. APPLICATION TUBULAR POST AND CURB SYSTEMS MAY BE USED TO DIVIDE OPPOSING LANES OF TRAFFIC OR TO DIVIDE TRAFFIC LANES WHEN TWO OR MORE LANES ARE KEPT OPEN IN THE SAME DIRECTION. FASTENING THE CURBS TO THE PAVEMENT WITH ANCHOR BOLTS OR OTHER SUITABLE METHODS AS DIRECTED BY THE MANUFACTURER IS REQUIRED TO MINIMIZE THE CHANCE OF BEING MOVED BY TRAFFIC. TUBULAR POST AND CURB SYSTEMS SHALL BE INSTALLED IN THE LOCATIONS SHOWN IN THE PLANS OR DIRECTED BY THE ENGINEER. VERTICAL PANELS DESIGN RETROREFLECTIVE MATERIAL ON VERTICAL PANELS SHALL BE 12 INCHES WIDE AND AT LEAST 24 INCHES HIGH. THEY SHALL HAVE ALTERNATING ORANGE AND WHITE STRIPES, WHERE THE HEIGHT OF THE RETROREFLECTIVE MATERIAL ON THE VERTICAL PANEL IS MORE THAN 36 INCHES, A PANEL STRIPE WIDTH OF 6 INCHES SHALL BE USED. WHERE THE HEIGHT OF THE RETROREFLECTIVE MATERIAL ON THE VERTICAL PANEL IS 36 INCHES OR LESS, A PANEL STRIPE WIDTH OF 4 INCHES SHALL BE USED. IF USED FOR TWO-WAY TRAFFIC, BACK-TO-BACK PANELS SHALL BE USED. MARKINGS FOR VERTICAL PANELS SHALL BE ALTERNATING ORANGE AND WHITE RETROREFLECTORIZED STRIPES SLOPING DOWNWARD AT AN ANGLE OF 45 DEGREES IN THE DIRECTION TRAFFIC IS TO PASS. POST MOUNTED VERTICAL PANELS SHALL BE MOUNTED WITH THE BOTTOM A MINIMUM OF 1 FOOT ABOVE THE ROADWAY. VERTICAL PANELS ON A TEMPORARY STAND SHALL BE MOUNTED WITH THE BOTTOM A MAXIMUM OF 1 FOOT ABOVE THE ROADWAY. APPLICATION WHERE SPACE IS LIMITED VERTICAL PANELS MAY BE USED TO CHANNEL TRAFFIC, DIVIDE OPPOSING LANES OF TRAFFIC, DIVIDE TRAFFIC LANES OR REPLACE BARRICADES. WHEN APPROVED BY THE ENGINEER, VERTICAL PANELS MAY BE POST -MOUNTED ALONG THE SIDE OF THE ROADWAY. TUBULAR POSTS DESIGN RETROREFLECTIVE WHITE TUBULAR POSTS SHALL BE PREDOMINANTLY ORANGE, NOT LESS THAN 28 INCHES HIGH, BE A MINIMUM OF 2 INCHES WIDE WHEN FACING TRAFFIC, AND MADE OF A MATERIAL THAT CAN BE STRUCK WITHOUT DAMAGING IMPACTING VEHICLES. TUBULAR POSTS SHALL BE RETROREFLECTIVE. RETROREFLECTION OF TUBULAR POSTS SHALL BE PROVIDED BY TWO 3 INCHES WIDE WHITE BANDS PLACED A MAXIMUM OF 2 INCHES FROM THE TOP, WITH A MAXIMUM OF 6 INCHES BETWEEN THE BANDS. THE BASE SHALL NOT BE WIDER THAN 12 INCHES OR HIGHER THAN 2 INCHES. APPLICATION TUBULAR POSTS HAVE LESS VISIBLE AREA THAN OTHER DEVICES AND SHOULD BE USED ONLY WHERE SPACE RESTRICTIONS DO NOT ALLOW FOR THE USE OF OTHER MORE VISIBLE DEVICES. THEY MAY BE USED EFFECTIVELY TO DIVIDE OPPOSING LANES OF TRAFFIC OR TO DIVIDE TRAFFIC LANES WHEN TWO OR MORE LANES ARE KEPT OPEN IN THE SAME DIRECTION. STEPS SHOULD BE TAKEN TO ASSURE THAT TUBULAR POSTS WILL NOT BE BLOWN OVER OR DISPLACED BY TRAFFIC BY EITHER AFFIXING THEM TO THE PAVEMENT WITH ANCHOR BOLTS OR ADHESIVE, IF A NONCYLINDRICAL DEVICE IS USED, IT SHALL BE ATTACHED TO THE PAVEMENT TO ENSURE THAT THE WIDTH FACING TRAFFIC MEETS THE MINIMUM REQUIREMENTS. TUBULAR POSTS SHOULD NOT BE USED FOR PEDESTRIAN CHANNELIZATION OR A PEDESTRIAN BARRIERS IN TEMPORARY TRAFFIC CONTROL ZONES ON OR ALONG SIDEWALKS. R6 R5 R4 REV. NO. JUN 14 2009 MUTCD UPDATE OCT 98 REVISE CHANNELIZATION DEVICES, TAPER JAN 95 REWRITE DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 920-R6 TRAFFIC CONTROL CONSTRUCTION AND MAINTENANCE ACCEPTED BY FHWA FOR USE ON NATIONAL HIGHWAY SYST DANIEL J. WADDLE E-6289 i JUNE 014 DATE ORIGINAL: OCTOBER 1998 DATE ROADWAY DESIGN DIVISION Computer: DRDESIGN55 0 M L 0 V m Co Date: 26 -FEB -2014 13:21 C rn • to 0 G..u- .. 0 N v w W 2 N OPPOSING TRAFFIC LANE DIVIDERS DESIGN OPPOSING TRAFFIC LANE DIVIDERS SHALL BE A TWO SIDED UPRIGHT RETROREFLECTORIZED ORANGE PANEL, WITH A WIDTH OF 12 INCHES AND A HEIGHT OF 18 INCHES. THE TOP OF THE PANEL SHALL BE 36 INCHES ABOVE THE PAVEMENT. THE SYMBOL ON EACH SIDE SHALL BE TWO OPPOSING BLACK ARROWS. THE LANE DIVIDER SHALL BE MADE OF LIGHTWEIGHT MATERIAL THAT WILL YIELD UPON IMPACT BY A VEHICLE. THE LANE DIVIDER BASE SHALL NOT BE WIDER THAN 12 INCHES OR HIGHER THAN 4 INCHES. THE BASE SHALL BE ATTACHED TO THE EXISTING SURFACE BY EPDXY OR OTHER SUITABLE ADHESIVE, TO ENSURE THAT THE PANEL REMAINS FACING TRAFFIC. APPLICATION OPPOSING TRAFFIC LANE DIVIDERS ARE DELINEATION DEVICES USED AS CENTER LANE DIVIDERS TO SEPARATE OPPOSING TRAFFIC ON A TWO—LANE, TWO—WAY OPERATION. FLAGGERS REQUIRED METHOD EMERGENCY USE ONLY TO STOP TRAFFIC TRAFFIC PROCEED e TO ALERT AND 'es SLOW TRAFFIC ee FLAGGER PADDLE THE STOP/SLOW PADDLE SHALL HAVE AN OCTAGONAL SHAPE ON A RIGID HANDLE. STOP/SLOW PADDLES SHALL BE AT LEAST 18 INCHES WIDE WITH LETTERS AT LEAST 6INCHES HIGH. IF THE STOP/SLOW PADDLE IS PLACED ON A RIGID STAFF, THE MINIMUM LENGTH OF THE STAFF, MEASURED FROM THE BOTTOM OF THE SIGN TO THE END OF THIS STAFF :THAT RESTS ON THE GROUND, SHOULD BE 5 FEET. THE STOP/SLOW PADDLE SHOULD BE THE PRIMARY AND PREFERRED HAND—SIGNALING DEVICE BECAUSE THE STOP/SLOW PADDLE GIVES ROAD USERS MORE POSITIVE GUIDANCE THAN RED FLAGS. USE OF FLAGS SHOULD BE LIMITED TO EMERGENCY SITUATIONS. FLAGGERS A FLAGGER MUST BE DRESSED FOR SAFETY. IN ADDITION TO THE REQUIREMENTS OF THE "WORKER VISIBILITY" SECTION LISTED BELOW, FLAGGERS SHALL WEAR: 1. AN ORANGE OR YELLOW/GREEN CAP OR HARD HAT. 2. A SHIRT WITH SLEEVES, PANTS AND SHOES (TANK TOPS, SHORTS OR SANDALS SHALL NOT BE WORN). FLAGGERS SHALL BE INSTRUCTED IN THE PROPER LOCATION, DUTIES AND; PROCEDURES FOR FLAGGING AS OUTLINED IN THE CURRENT MUTCD AND THE DEPARTMENT OF ROADS FLAGGER'S HANDBOOK. AS REQUIRED BY THE DEPARTMENT OF ROADS, THE FLAGGER SHALL BE CERTIFIED, AND HAVE IN THEIR POSSESSION, A VALID FLAGGER CERTIFICATION CARD. WORKER VISIBILITY ALL WORKERS WITHIN THE RIGHT—OF—WAY WHO ARE EXPOSED EITHER TO TRAFFIC (VEHICLES USING THE HIGHWAY FOR PURPOSES OF TRAVEL) OR TO CONSTRUCTION EQUIPMENT WITHIN THE WORK AREA SHALL WEAR HIGH—VISIBILITY SAFETY APPAREL. HIGH—VISIBILITY SAFETY APPAREL IS DEFINED TO MEAN PERSONAL PROTECTIVE SAFETY CLOTHING THAT; 1. IS INTENDED TO PROVIDE CONSPICUITY DURING BOTH DAYTIME AND NIGHTTIME USAGE, AND 2. MEETS THE PERFORMANCE CLASS 2 OR CLASS 3 REQUIREMENTS; OF THE ANSI/ISEA 107-2004 PUBLICATION ENTITLED "AMERICAN NATIONAL STANDARDS FOR HIGH— VISIBILITY SAFETY APPAREL AND HEADWEAR" LIGHTING DEVICES FUNCTION CONSTRUCTION AND. MAINTENANCE ACTIVITIES OFTEN CREATE CONDITIONS ON OR NEAR THE TRAVELED WAY THAT ARE PARTICULARLY HAZARDOUS AT NIGHT. IT IS OFTEN DESIRABLE AND NECESSARY TO SUPPLEMENT THE REFLECTORIZED SIGNS, BARRIERS, AND CHANNELIZING DEVICES WITH LIGHTING DEVICES. STROBE TYPE LIGHTS ARE NOT PERMITTED. BARRICADE WARNING LIGHTS DESIGN (BATTERY OPERATED) TYPE "A" LOW INTENSITY FLASHING WARNING LIGHTS ARE MOST COMMONLY MOUNTED ON BARRICADES, OR WITH SIGNS AND ARE INTENDED TO WARN THE DRIVER THAT THEY ARE PROCEEDING IN A HAZARDOUS AREA. THESE LIGHTS SHALL NOT BE USED FOR DELINEATION, AS A SERIES OF FLASHING LIGHTS IN A ROW WOULD TEND TO OBSCURE THE DESIRED PATH. TYPE "A" HIGH INTENSITY FLASHING WARNING LIGHTS ARE NORMALLY MOUNTED ON THE TYPE III BARRICADE THAT ACCOMPANIES THE ADVANCE WARNING SIGNS. TYPE "C" STEADY BURN LIGHTS AS USED HEREIN, SHALL MEAN A SERIES OF LOW WATTAGE YELLOW ELECTRIC LIGHTS. WHERE LIGHTS ARE NEEDED TO DELINEATE OR MARK THE TRAVELED WAY THROUGH AND AROUND OBSTRUCTIONS IN A CONSTRUCTION MAINTENANCE AREA, THE DELINEATION SHALL BE ACCOMPLISHED BY USE OF STEADY BURNING LIGHTS. WHEN USED TO SUPPLEMENT CHANNELIZATION, THE MAXIMUM SPACING FOR WARNING LIGHTS SHOULD BE IDENTICAL TO THE CHANNELIZING DEVICE SPACING REQUIREMENTS. WHEN USED TO DELINEATE A CURVE, TYPE "C" WARNING LIGHTS SHOULD ONLY BE USED ON DEVICES ON THE OUTSIDE OF THE CURVE, AND NOT ON THE INSIDE OF THE CURVE. FLASHING ARROW PANEL (DISPLAY) AN ARROW PANEL IS A SIGN WITH A MATRIX OF ELEMENTS, CAPABLE OF EITHER FLASHING OR SEQUENTIAL DISPLAYS. THIS SIGN SHALL PROVIDE ADDITIONAL WARNING AND DIRECTIONAL INFORMATION TO ASSIST IN MERGING AND CONTROLLING ROAD USERS THROUGH OR AROUND A TEMPORARY TRAFFIC CONTROL ZONE. AN ARROW PANEL SHOULD BE USED IN COMBINATION WITH APPROPRIATE SIGNS, CHANNELIZING DEVICES OR OTHER TRAFFIC CONTROL DEVICES. DESIGN . ARROW PANELS SHALL MEET THE SIZE AND SPECIFICATIONS OF THE MUTCD FOR TYPE "C" ARROW DISPLAYS. FLASHING ARROW PANEL SHALL BE RECTANGULAR, OF SOLID APPEARANCE AND FINISHED IN NON—REFLECTIVE BLACK. THE PANEL SHALL BE MOUNTED ON A VEHICLE, TRAILER OR OTHER SUITABLE SUPPORT. MINIMUM MOUNTING HEIGHT MEASURED VERTICALLY FROM THE BOTTOM OF THE PANEL TO THE ROADWAY BELOW IT OR TO THE ELEVATION OF THE NEAR EDGE OF THE ROADWAY. SHALL BE 7 FEET EXCEPT ON VEHICLE—MOUNTED PANELS, WHICH SHOULD BE AS HIGH AS PRACTICAL. THE FOLLOWING SELECTIONS SHALL BE PROVIDED ON THE ARROW PANEL OPERATING MODE PANEL DISPLAY FLASHING ARROW L MINIMUM SHIFTING TAPER • • SHOULDER TAPER RIGHT SHOWN; LEFT OPPOSITE SEQUENTIAL ARROW 100 FEET MAXIMUM 30 ••• • •• • ••C• • • •••• t• • 35 RIGHT SHOWN; LEFT OPPOSITE SEQUENTIAL CHEVRON .245 40 .•• • .••.•• • .••.••.•• 45 RIGHT SHOWN; LEFT OPPOSITE FLASHING DOUBLE ARROW .540 50 •:•• S• 550 600 FLASHING OR ALTERNATING CAUTION 550 605 .660 OR• • • • OR FLASHING FLASHING LINE CORNERS 65 • 715 401 75 ALTERNATING DIAMOND CAUTION THE ARROW PANEL SHALL HAVE A MINIMUM SIZE OF 96 INCHES WIDE AND 48 INCHES HIGH. THE MINIMUM LEGIBILITY DISTANCE SHALL BE 1 MILE. THE PANEL SHALL CONTAIN 25 LAMP ELEMENTS. ARROW PANEL ELEMENTS SHALL BE CAPABLE OF A MINIMUM 50 PERCENT DIMMING, AUTOMATICALLY WHEN AMBIENT LIGHT FALLS BELOW 50 LUX. THE MINIMUM ELEMENT "ON TIME" SHALL BE 50 PERCENT FOR THE FLASHING MODE AND EQUAL INTERVALS OF 25 PERCENT FOR EACH SEQUENTIAL CHEVRON PHASE. THE FLASHING RATE SHALL BE NO FEWER THAN 25 NOR MORE THAN 40 FLASHES PER MINUTE. APPLICATION A FLASHING ARROW OR SEQUENTIAL CHEVRON MODE SHALL ONLY BE USED FOR STATIONARY OR MOVING LANE CLOSURES. FOR SHOULDER WORK BLOCKING THE SHOULDER, FOR ROADSIDE WORK NEAR THE SHOULDER, OR FOR TEMPORARILY CLOSING ONE LANE ON A TWO—LANE, TWO—WAY ROADWAY, AN ARROW PANEL SHALL BE USED ONLY IN THE CAUTION MODE. AN ARROW DISPLAY MODE SHALL NOT BE USED ON A TWO—LANE TWO—WAY ROADWAY FOR TEMPORARY ONE—LANE OPERATION OR LANE SHIFTS. AN ARROW DISPLAY SHALL NOT BE USED TO LATERALLY SHIFT TRAFFIC. TEMPORARY RUMBLE STRIPS EACH SECTION SHALL CONSIST OF 10 SEGMENTS. 6" 24' EDGE OF TRAVELED LANE O r A M tzi M i = 3 1111iiiIISM Q � q N Y ti 11111 IOF ROADWAY 23' DESIGN TEMPORARY RUMBLE STRIPS MAY BE MADE OF ASPHALT PAVING MATERIAL, EPDXY AND AGGREGATE OR OTHER SUITABLE MATERIAL WHICH WILL MAINTAIN A DESIRABLE RUMBLE EFFECT. THE TEMPORARY RUMBLE STRIP SHOULD HAVE AN INSTALLED HEIGHT OF 5/8'. PREFORMED RUMBLE STRIPS MAY BE USED PROVIDED THEY HAVE A MINIMUM 1/2' HEIGHT. TRAFFIC SIGNALS TRAFFIC SIGNALS MAY BE ALLOWED AT CERTAIN EQUIPMENT CROSSINGS WHERE THE VOLUME OF FILL MATERIAL AND THE NUMBER OF EQUIPMENT CROSSINGS PER HOUR IS HIGH. TRAFFIC SIGNALS MAY BE ALLOWED AT CERTAIN BRIDGE CONSTRUCTION SITES WHERE A COMBINATION OF ONE—WAY TRAFFIC AND HIGH TRAFFIC VOLUMES WOULD BE BEST SERVED WITH THIS TYPE OF TRAFFIC CONTROL. ALL TRAFFIC SIGNAL REQUESTS AND METHOD OF INSTALLATION ON THE STATE HIGHWAY SYSTEM SHALL BE IN COMPLIANCE WITH THE MUTCD AND MUST BE APPROVED BY THE STATE TRAFFIC ENGINEER. IF, AFTER THE SIGNAL ASSEMBLIES ARE ERECTED AND THE ROAD IS OPEN TO PUBLIC TRAVEL, THE SIGNAL SYSTEM IS NOT PUT IMMEDIATELY INTO OPERATION, THE SIGNAL FACES SHALL BE COVERED WITH BURLAP OR OTHER OPAQUE MATERIAL SUBJECT TO THE APPROVAL OF THE ENGINEER, INOPERATIVE SIGNALS ON ROADS OPEN TO THE PUBLIC SHALL ALWAYS BE COVERED. TILTING THE SIGNALS UPWARD IS NOT AN ACCEPTABLE ALTERNATIVE TO COVERING THE HEADS. FLOODLIGHTS WHEN NIGHTTIME WORK IS REQUIRED, FLOODLIGHTS SHALL BE USED TO'ILLUMINATE FLAGGER STATIONS. FLOODLIGHTS SHOULD BE USED TO ILLUMINATE EQUIPMENT CROSSINGS, AND OTHER AREAS WHERE EXISTING LIGHT IS NOT ADEQUATE FOR THE WORK TO BE PERFORMED SAFELY. IN NO CASE SHALL FLOODLIGHTING BE PERMITTED TO CREATE A DISABLING GLARE FOR DRIVERS. THE ADEQUACY OF THE FLOODLIGHT PLACEMENT AND ELIMINATION OF POTENTIAL GLARE SHOULD BE CHECKED BY DRIVING THROUGH THE PROJECT. PAVEMENT MARKING IT IS INTENDED TO THE EXTENT POSSIBLE, THAT MOTORISTS BE PROVIDED MARKINGS WITHIN A WORK AREA COMPARABLE TO THE MARKINGS NORMALLY MAINTAINED ALONG ADJACENT ROADWAYS, PARTICULARLY AT EITHER END OF THE WORK AREA. ALL MARKINGS AND DEVICES USED TO DELINEATE VEHICLE AND PEDESTRIAN PATHS SHALL BE CAREFULLY REVIEWED DURING DAYTIME AND NIGHTTIME PERIODS TO AVOID INADVERTENTLY LEADING DRIVERS OR PEDESTRIANS FROM THE INTENDED PATH. PAVEMENT MARKINGS NO LONGER APPLICABLE SHALL BE REMOVED UNLESS OTHERWISE APPROVED BY THE ENGINEER. TAPERS TAPERS ARE CREATED USING A SERIES OF CHANNELIZING DEVICES OR PAVEMENT MARKINGS TO MOVE TRAFFIC OUT OF OR INTO ITS NORMAL PATH. MERGING TAPER A MERGING TAPER REQUIRES THE LONGEST DISTANCE BECAUSE DRIVERS ARE REQUIRED TO MERGE INTO COMMON ROAD SPACE. THE TAPER SHOULD BE LONG ENOUGH TO ENABLE MERGING DRIVERS TO HAVE ADEQUATE ADVANCE WARNING AND SUFFICIENT LENGTH TO ADJUST THEIR SPEEDS AND MERGE INTO A SINGLE LANE BEFORE THE DOWNSTREAM END OF THE TRANSITION. SHIFTING TAPER A SHIFTING TAPER IS USED WHEN MERGING IS NOT REQUIRED, BUT A LATERAL SHIFT IS NEEDED. APPROXIMATELY ONE—HALF "L" HAS BEEN FOUND TO BE ADEQUATE. WHERE MORE SPACE IS AVAILABLE, IT MAY BE BENEFICIAL TO USE LONGER TAPERS. GUIDANCE FOR CHANGES IN ALIGNMENT MAY ALSO BE ACCOMPLISHED BY USING HORIZONTAL CURVES DESIGNED FOR NORMAL HIGHWAY SPEEDS. SHOULDER TAPERS A SHOULDER TAPER MAY BE BENEFICIAL ON HIGH—SPEED ROADWAYS WHERE SHOULDERS ARE PART OF THE ACTIVITY AREA AND ARE CLOSED, OR WHEN IMPROVED SHOULDERS MIGHT BE MISTAKEN AS A DRIVING LANE IN THESE INSTANCES, THE SAME TYPE, BUT ABBREVIATED, CLOSURE PROCEDURES USED ON A NORMAL PORTION OF THE ROADWAY CAN BE USED. IF USED, SHOULDER TAPERS APPROACHING THE ACTIVITY AREA SHOULD HAVE A LENGTH OF ABOUT ONE—THIRD "L". DOWNSTREAM TAPERS THE DOWNSTREAM TAPER MAY BE USEFUL IN TERMINATION AREAS TO PROVIDE A VISUAL CUE TO THE DRIVER THAT ACCESS IS AVAILABLE TO THE ORIGINAL LANE OR PATH THAT WAS CLOSED. WHEN USED, IT SHOULD HAVE A MINIMUM LENGTH OF ABOUT 100 FEET PER LANE, WITH DEVICES SPACED ABOUT 20 FEET APART. ONE LANE, TWO WAY TAPER THE ONE—LANE, TWO—WAY TAPER IS USED IN ADVANCE OF AN ACTIVITY AREA THAT OCCUPIES PART OF A TWO—WAY ROADWAY IN SUCH A WAY THAT A PORTION OF THE ROAD IS USED ALTERNATELY BY TRAFFIC IN EACH DIRECTION. A SHORT TAPER HAVING A MINIMUM LENGTH OF 50 FEET AND A MAXIMUM LENGTH OF 100 FEET WITH CHANNELZING DEVICES AT APPROXIMATELY 20 FOOT SPACINGS SHOULD BE USED TO GUIDE TRAFFIC INTO THE ONE—LANE—SECTION AND A DOWNSTREAM TAPER WITH A LENGTH OF APPROXIMATELY 100 FEET SHOULD BE USED TO GUIDE TRAFFIC BACK INTO THEIR ORIGINAL LANE. TAPER LENGTH CRITERIA FOR TEMPORARY TRAFFIC CONTROL ZONES TYPE OF TAPER TAPER LENGTH (FEET) MERGING TAPER L MINIMUM SHIFTING TAPER 1/2 L MINIMUM SHOULDER TAPER 1/3 L MINIMUM TWO—WAY TAPER 100 FEET MAXIMUM FORMULAS FOR L SPEED FORMULA 40 MPH OR LESS —W52 L 60 45 MPH OR GREATER L = WS L = TAPER LENGTH IN FEET W = WIDTH OF OFFSET IN FEET S = POSTED SPEED LIMIT PRIOR TO WORK IN MPH TAPER LENGTH L (FEET) SPEED (MPH) LANE WIDTH S 10 FT. 11 FT. 12 FT. 25 105 115 ':125 30 150 165 .180 35 205 225 .245 40 270 295 ,320 45 450 495 .540 50 500 550 600 55 550 605 .660 60 600 660 720 65 650 715 780 75 750 825 900 R6 R5 R4 REV. NO. JUN 14 OCT 98 JAN 95 DATE 2009 MUTCD UPDATE REVISE CHANNELIZATION DEVICES, TAPER REWRITE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 920-R6 TRAFFIC CONTROL CONSTRUCTION AND MAINTENANCE ACCEPTED BY FHWA FOR USE 0 NATIONAL HIGHWAY SYSTE i o . DANIEL J. orti 141 a WADDLE I. E-6289 N * OF < JUNE 2S 4 DATE ORIGINAL: OCTOBER 1998 DATE ROADWAY DESIGN DIVISION r -- ES 0 M i 0 v i- 0 N N M v 0 0 W U- N a) 0 0 C rn 0 0 0 00 N "M �0 my ro i.i U) i— lei W 2 0 ROADSIDE SIGNS HEIGHT AND LATERAL LOCATION OF SIGNS RURAL AREA PAVED SHOULDER URBAN AREA TYPICAL FIRST SIGN AT CONSTRUCTION SITE WITH TYPE "A" FLASHING WARNING LIGHT MOUNTED ABOVE TYPE III BARRICADE WITH SPEED ADVISORY PLATE ROAD CLOSED 500 FT PORTABLE AND TEMPORARY MOUNTING TYPICAL SIGN MOUNTINGS POST MOUNTED SIGNS 48 INCHES OR WIDER REQUIRE TWO POSTS SIGN WIDTHS LESS THAN48 INCHES MAY BE MOUNTED WITH -ONE POST TYPICAL SIGN MOUNTINGS OTHER THAN POST MOUNTED TYPE III BARRICADE WITH SIGN ROAD CLOSED `": DETOUR111.116.11.11.11.111 TYPE III BARRICADE WITH SIGN AND DETOUR ARROW TYPE II BARRICADE WITH DETOUR ARROW OR SIGN MIN. 1 FT. ABOVE PAVEMENT 1500 FTI PORTABLE AND TEMPORARY MOUNTING TYPE III BARRICADE WITH CHEVRONS PLASTIC DRUM WITH CHEVRON OR SIGN TEMPORARY SIGN SUPPORTS ALL "TEMPORARY SIGN" SUPPORTS (BASES) SHALL BE NCHRP 350 OR MASH (TL -3) APPROVED. "TEMPORARY SIGNS" ARE ALL TEMPORARILY MOUNTED WORK ZONE SIGNS THAT ARE NOT POST MOUNTED IN THE GROUND AT THE TYPICAL 5 FOOT MOUNTING HEIGHT. TEMPORARY SIGNS ARE CONSIDERED NCHRP 350 OR MASH CATEGORY 2 DEVICES AND ARE MOUNTED ON TEMPORARY SIGN STANDS. TEMPORARY SIGNS SHALL BE MOUNTED A MINIMUM OF 1 FOOT ABOVE THE GROUND, UNLESS OTHERWISE REQUIRED TO BE MOUNTED AT A HIGHER HEIGHT. TEMPORARY SIGNS AND THEIR SUPPORTS SHALL NOT BE IN PLACE LONGER THAN 3 DAYS. ANY SIGN THAT IS TO BE IN PLACE LONGER THAN 3 DAYS SHALL BE POST MOUNTED OR MOUNTED TO A DRUM, BARRICADE, OR BARRIER, AS REQUIRED BY THE PLANS OR SPECIFICATIONS. PORTABLE DYNAMIC MESSAGE SIGN DELINEATION 0 �--� PDMS 0 0 IN MEDIAN 3'-0" MIN. J M --OUTSIDE CLEAR ZONE ON SHOULDER OFF SHOULDER PORTABLE DYNAMIC MESSAGE SIGNS (PDMS) THE PLACEMENT OF PDMS SHOULD BE IN THE FOLLOWING ORDER: WHENEVER POSSIBLE, PDMS SHOULD BE PLACED OFF OF ANY USABLE PORTION OF THE ROADWAY ON THE RIGHT SIDE OF THE ROADWAY. WHEN PLACED OUTSIDE THE CLEAR ZONE OR BEHIND GUARDRAIL OR CONCRETE PROTECTION BARRIERS, DELINEATION IS NOT REQUIRED. WHERE FIELD CONDITIONS DO NOT ALLOW FOR THIS PLACEMENT, THE SIGNS MAY BE LOCATED ON THE OUTSIDE SHOULDER OF THE ROADWAY OR WITHIN THE MEDIAN. A. A MINIMUM CLEARANCE OF 3 FEET MEASURED HORIZONTALLY FROM THE EDGE OF THE SIGN TO THE EDGE OF THE TRAVELED WAY IS RECOMMENDED. B. THE PDMS SHOULD HAVE A MINIMUM MOUNTED HEIGHT OF 7 FEET ON FREEWAYS, EXPRESSWAYS AND IN URBAN AREAS. C. ALL OTHER RURAL APPLICATIONS SHOULD HAVE A MINIMUM HEIGHT OF 5 FEET. THESE HEIGHTS ARE MEASURED VERTICALLY FROM THE BOTTOM OF THE SIGN TO THE ELEVATION OF THE NEAR EDGE OF THE PAVEMENT. REFLECTORIZED PLASTIC DRUMS SHOULD BE USED TO DELINEATE EACH SIGN USING A 1/3 L TAPER. THESE DRUMS SHOULD BE POSITIONED ON THE UPSTREAM END OF THE SIGN TO FORM A TAPER LEADING UP TO THE TRAFFIC SIDE OF THE SIGN. FOR A SIGN LOCATED IN THE MEDIAN, THE SIGN SHOULD BE DELINEATED WITH A 42 INCH CONE ON ALL FOUR CORNERS. WHEN DEPLOYED, THE SIGN SHALL BE SIGHTED AND ALIGNED WITH APPROACHING TRAFFIC TO ENSURE VISIBILITY OF THE MESSAGE. IF MULTIPLE SIGNS ARE USED, THE SIGNS SHOULD BE LOCATED ON THE SAME SIDE OF THE ROAD AND SEPARATED ACCORDING TO PROPER SIGN SPACING. WHEN PRACTICAL, PDMS SHOULD NOT BE USED TO REPLACE STATIC SIGNS FOR LONG TERM USAGE (OVER 10 DAYS). WHEN PDMS ARE TO BE DEPLOYED FOR LONG PERIODS, SUCH AS INCIDENT MANAGEMENT ROLES, CONCRETE PADS WITH APPROPRIATE TIE DOWNS SHOULD BE CONSTRUCTED FOR THEIR PLACEMENT. PDMS NOT ACTIVELY BEING USED IN A CONSTRUCTION OR INCIDENT MANAGEMENT ROLE SHOULD BE REMOVED. REFER TO NDOR "DMS GUIDELINES" FOR PROPER PDMS MESSAGE INFORMATION. NOTES 1. ALL TRAFFIC CONTROL DEVICES SHALL MEET THE APPLICABLE STANDARDS AND SPECIFICATIONS PRESCRIBED IN PART 6 OF THE LATEST ADOPTED EDITION OF THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, (MUTCD)" AND THE STATE OF NEBRASKA SUPPLEMENT TO THE MUTCD. ALL TRAFFIC CONTROL DEVICES SHALL BE CRASHWORTHY AND QUALIFY AS SUCH ACCORDING TO THE TESTING AND ACCEPTANCE GUIDELINES OF THE NATIONAL COOPERATIVE HIGHWAY RESEARCH PROGRAM (NCHRP) REPORT 350 OR MANUAL FOR ASSESSING SAFETY HARDWARE (MASH). 2. TRAFFIC CONTROL PLANS AND DEVICES SHOULD FOLLOW THE PRINCIPLES SET FORTH, BUT MAY DEVIATE FROM THE TYPICAL DRAWINGS TO ALLOW FOR CONDITIONS AND REQUIREMENTS OF THE PROJECT. 3. TRAFFIC CONTROL DEVICES SHALL BE INSTALLED SO AS NOT TO OBSTRUCT THE VIEW OF OTHER TRAFFIC CONTROL DEVICES. 4. THE ENGINEER SHALL HAVE THE AUTHORITY TO REQUIRE THE USE, AND APPROVE THE LOCATION OF ANY OF THE DEVICES SHOWN IN THESE PLANS. WORK ZONE SPEED LIMIT NOTES A. WORK ZONE SPEED LIMITS SHALL NOT BE INSTALLED WITHOUT A SPEED ZONE AUTHORIZATION COMPLETED BY THE DEPARTMENT. B. REDUCED SPEED LIMITS SHOULD BE USED ONLY IN THE SPECIFIC PORTION OF THE WORK ZONE WHERE CONDITIONS OR RESTRICTIVE FEATURES ARE PRESENT. HOWEVER. FREQUENT CHANGES IN THE SPEED LIMIT SHOULD BE AVOIDED. THE REDUCTION OF SPEED SHOULD BE DESIGNED SO VEHICLES CAN SAFELY TRAVEL THROUGH THE WORK ZONE WITH A SPEED LIMIT REDUCTION OF NO MORE THAN 10 MPH UNLESS OTHERWISE NOTED IN THE PLANS. C. WORK ZONE SPEED LIMITS SHOWN ARE TYPICAL APPLICATIONS ONLY AND ARE NOT TO BE ASSUMED AS THE SPEED LIMITS REQUIRED FOR THE WORK. D. EXISTING SPEED LIMIT SIGNS SHALL BE REMOVED OR COVERED WHEN A REDUCED WORK ZONE SPEED LIMIT IS IN EFFECT IN THE SAME AREA. E. WORK ZONE SPEED LIMIT SIGNS SHALL BE INSTALLED EVERY MILE THROUGH THE WORK AREA WHEN SPEED ZONE IS REDUCED. F. A SPEED LIMIT SIGN ENDING THE REDUCED SPEED ZONE SHALL BE INSTALLED AT THE END OF EACH ZONE. G. DOUBLE FINES AND REDUCED SPEED ZONE SIGNING ARE NOT REQUIRED FOR SHORT -DURATION WORK LESS THAN 12 HOURS. TAPER FORMULA L = S x W FOR SPEEDS OF 45 MPH OR MORE. L = 6 2 FOR SPEEDS OF 40 MPH OR LESS. WHERE: L = MINIMUM LENGTH OF TAPER. S = NUMERICAL VALUE OF POSTED SPEED LIMIT PRIOR TO WORK. W =WIDTH OF OFFSET (LANE WIDTH). LEGEND C::= TYPE III BARRICADE • 0 REFLECTORIZED PLASTIC DRUM REFLECTORIZED PLASTIC DRUM. OR 42" CONE PORTABLE DYNAMIC MESSAGE SIGN R6 JUN 14 R5 OCT 98 R9 JAN 95 REV. NO. DATE 2009 MUTCD UPDATE REVISE CHANNELIZATION DEVICES, TAPER REWRITE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 920-R6 TRAFFIC CONTROL CONSTRUCTION AND MAINTENANCE ACCEPTED BY FHWA FOR USE 0 NATIONAL HIGHWAY SYSTEM° DANIEL J. WADDLE E-6289 JUNE 20 4 DATE ORIGINAL: OCTOBER 1998 DATE ROADWAY DESIGN DIVISION In U, z U) w 0 0 cc L a) a 0 .0 N 0 M L 0 .0 L 0 y 27 -FEB -2014 08:25 3 0 mo 00 N .au - gio055 a)o 0 _ U� LL N LU w w s CROSS ROAD INTERSECTING CLOSED ROAD ii/"i"/ /' ii CLOSED i i i i i i i //////// // ////' i ROAD, ," /iii//i/ ROAD CLOSED R11-2-48 W/TYPE A WARNING LIGHT MOUNTED ABOVE TYPE III BARRICADE ADDITIONAL TYPE III BARRICADES MAY BE USED AS NEEDED 1 W20 -3A-48 ROAD CLOSED 1 MILES AHEAD LOCAL TRAFFIC ONLY R11 -3A-60 TRAFFIC NOT ALLOWED TO CROSS CLOSED ROAD ROAD CLOSED PLASTIC DRUMS AS ;`NEEDED TO DELINEATE .OPEN TRAVEL AREA OR ROAD CLOSED TO THRU TRAFFIC R11-2-48 R1t-4-60 W/TYPE A WARNING LIGHT MOUNTED ABOVE TYPE III BARRICADE ADDITIONAL TYPE III BARRICADES MAY BE USED AS NEEDED 0 0 0 U, W20 -1A-48 TRAFFIC ALLOWED TO CROSS CLOSED ROAD ROAD CLOSED R11-2-48 ROAD CLOSED X MILES AHEAD LOCAL TRAFFIC ONLY R11 -3A-60 SEE OR OR ROAD CLOSED BEYOND JUNCTION BRIDGE OUT R11 -2A-48 BRIDGE OUT X MILES AHEAD LOCAL TRAFFIC ONLY NOTE 7 R11 -3B-60 W40-11-48 OPTIONAL W20 -3B-48 SIDE ROAD 5oo��b STOP W20 -1A-48 * WEST DETOUR NORTH 66 R1-1-30 * 66 W20 -3C-48 SIDE R1-1-30 1 500' W20 -1A-48 SIDE ROAD DETOUR NORTH 66 * COVER WITH 1 ROAD CLOSED X MILES AHEAD LOCAL TRAFFIC ONLY OR BRIDGE OUT X MILES AHEAD LOCAL TRAFFIC ONLY R11 -3A-60 R11 -3B-60 MOUNTED OVER DETOUR M4 -10L-48 WITH TYPE A WARNING LIGHTS MOUNTED ON TYPE III BARRICADE I 1 i I I I 1 I I 1 I I 0 0 In 0 0 In DETOUR 66 4 * m 1+ COVER WITH 500' W20 -2D-48 TOWN 4- TOWN TOWN XX XX 'XX -> CLOSED TO XXXX USE HWY XX 8. XX TO XXXX USE WHERE APPLICABLE 0 0 In 0 0 a7 W20 -2D-48 W20 -3A-48 W/TYPE A WARNING LIGHT MOUNTED ABOVE TYPE III BARRICADE * COVER SIGN COVERS OVER REFLECTIVE MATERIAL SHALL BE INSTALLED WITH SPACERS TO PREVENT DAMAGE NOTES 1. SIGNS SHOWN ARE USUALLY FOR ONE DIRECTION OF TRAVEL ONLY. 2. THE CONTRACTOR SHALL INSTALL, MAINTAIN, AND REMOVE ALL SIGNS IN ACCORDANCE WITH THE DETAILS OF AND AT THE LOCATIONS SHOWN IN THE PLANS. SIGNS INSTALLED BY THE DEPARTMENT OF ROADS OR OTHER GOVERNMENT AGENCY SHALL BE MAINTAINED AND REMOVED BY THEIR FORCES. 3. WHEN MESSAGE IS NOT PERTINENT, SIGNS SHALL BE TAKEN DOWN, COVERED OR FOLDED. TAPE IS NOT PERMITTED ON THE FACE OF THE SIGN. 4. VEHICLES OR EQUIPMENT SHALL NOT BE PARKED SO AS TO OBSCURE OR DISTRACT FROM TRAFFIC CONTROL DEVICES. 5. FLAGS MAY BE USED TO CALL ATTENTION TO WARNING SIGNS. 6. WHEN APPROPRIATE THE SIGN R11 -2B "BRIDGE OUT" MAY BE USED INSTEAD OF R11-2 "ROAD CLOSED". 7. BARRICADE AND SIGN MAY BE PLACED ALONG EDGE OF ROAD IF NEEDED FOR LOCAL TRAFFIC. 8. REFER TO STANDARD PLAN 920 FOR GENERAL INFORMATION NOT SHOWN. ROAD CLOSED AT JUNCTION ROAD CLOSED DETOUR LEGEND I I TYPE III BARRICADE • REFLECTORIZED PLASTIC DRUM SINGLE POSTED SIGN DOUBLE POSTED SIGN * INSTALLED BY OTHERS TAPER FORMULA L = S x W FOR SPEEDS OF 45 MPH OR MORE. L = 6o 2 FOR SPEEDS OF 40 MPH OR LESS. WHERE: L = MINIMUM LENGTH OF TAPER. S = NUMERICAL VALUE OF POSTED SPEED LIMIT PRIOR TO WORK. W = WIDTH OF OFFSET (LANE WIDTH). R11-2-48 M4-10-48 R1 JUN 19 2009 MUTCD UPDATES REV. NO. DATE DESCRIPTION OF REVISION NEBRASKA DEPARTMENT OF ROADS STANDARD PLAN NO. 923-R1 TRAFFIC CONTROL ROAD CLOSURE ACCEPTED BY FHWA FOR USE 0 NATIONAL HIGHWAY SYSTEM - ' -- FAf N68R• — JUNE 2014 DATE ORIGINAL: AUGUST 1998 DATE