Loading...
HomeMy WebLinkAboutR2002-1"4- 4) 4) L V) -4— fn seph Ave® ver 4 1/2" to 5" Existing Asphalt / Remove VAIRES Concrete Subgrade 2" Top Lift Typical Section of Existing Streets St. JOSEPH Ave. "1st." to "7th." No Scale 3" Bose Lift Concrete Subgrade itt VARIES Proposed Section St. JOSEPH Ave. "1st." to "7th." No Scale 4) 4) L (/I L M v U J 43.00 oy 1 st® 7th® Adams County Courthouse Grote Inlet Gate Inlet 00 1236.00 30.00 — 7th Street St Joe ASenue ESTIMATED QTY. FOR St. JOSEPH AVE. lst. to 7th. 1T0M NO. DESCRIPTION 1 2 3 Rotomill Pavement Asphaltic Concrete Type 14 Asphaltic Concrete Type 17c/.40 4 Asphaltic Cement (P669-22)' 5 Emulsified Asph. (SS 1H) Tack Coat 6 Adjust Manhole to Grade 7 Adjust Gas Valve to Grade 8 Adjust Water Valve to Grade 9 Saw Cut 10 Remove 30" curb & gutter 11 Build 30" curb & gutter 12 Concrete Patching (High Early) 13 Asphalt Driveway Patching 17c/.40 ESTIMATED QUAN 1'II IES 8050 1500 1010 146 2010 3 9 8 510 210 210 250 10 UNIT S.Y. Ton Ton Ton Gal. Each Each Each L.F. L.F. L.F. S.Y. Ton 100' NORTH Scale: 1"=100' 0' 100' 200' NOTES: Base Lift will consist of 3" Type 14 Top Lift will consist of 2" Type 17c/.40 Asphalt sub -base may require various patching to be determined by Engineer after milling operation and street has been cleaned. * Ends and returns on Project will be sawed prior to installation of Base Lift. Contractor shall use caution not to damage driveways during the removal of existing asphalt. Contractor will lay asphalt up to the existing concrete on 2nd and 3rd. street. Millings to be hauled to city landfill to be stockpiled. Top Lift of Asphalt shall cover flow lines in the gutter on both sides unless specified otherwise. Extra care will be taken to maintian water flow. Contractor is resposible to place Asphalt inset into driveways where needed. Contractor shall use care when moving heavy equipment over and around this project the sub -base will not withstand heavy weight. 300' et s•• • o•eeeea• i0 7 •lfie°° °i DAVID L =r!'.° WACKER _c )• EE -5090 `�` y3G^ao•oo Y'^7 LCi dl4 •e e.aea• lF pc ,. CITY OF HASTINGS, ENGINEERING DEPT. Project St. Joseph Ave. lst. to 7th. Proj. No. R-2002-1 Description Asphalt Overlay Design By Jeff L. Dote 1 /02 Contractor Oram By Jeff L. Approvea`)� V citty Drn. No. 4 of 4 2 MATERIALS - GENERAL REQUIREMENTS 1. Type of Asphaltic Oil for Tack coat Tack coat required under this project shall be 55-1 11. Water used to dilute emulsified asphalt shall be mixed in approximate 50-50 proportion with the oil. The rate of application of the diluted emulsified asphalt shall generally be from .10 to .20 of a gallon per square yard. 2. Asphaltic Concrete Type 14 & 17 asphalt according to State Specifications 3. Payment shall be made per ton asphalt and shall include all installation costs including, but not limited to sweeping and base preparation not otherwise provided for by separate pay item. NOTE: Contractor will take extra care to protect all survey markers, located in street, during construction. NOTE: Care will be taken to salvage existing manhole rings and covers and keep sets matched together. NOTE: Where pavement is milled, apply courses as specified to thickness as outlined on the plans or as specified in field by Engineer. NOTE: Salvage subbase in areas as specified on plans or as directed in field by Engineer. ASPHALT PAVEMENT SPEC. SHEET Laying, compacting and finishing shall be in accordance with sections 503and11028 of the 1997 Standard State Specifications and 2001 Supplemental Specifications. Flagging and barricades necessary for construction will not be paid for directly, but will be subsidiary to the contract. CONTRACTOR'S NOTE 1. Payment will be made for actual field quantities utilized and shall show precedence over contract estimated quantities. 2. Locations of all manholes and valves will be tied off and recorded prior to any work. Manholes will be kept covered and kept clean throughout all of resurfacing project. 3. All drives and approaches will be asphalted back, as directed by Engineer in field. 4. It will be the responsibility of the Contractor to dispose all pavement removal. 5. Any earth excavation will be disposed of on-site on adjacent lots. 6. Contractor will be required to notify property owners a minimum of 24 hours prior to any work being started, so cars, etc. can be moved. 7. Contractor will lay new asphalt surface in a two lift process. Unless otherwise specified by plans or Engineer. 8. Contractor will be required to have all utilities located prior to start of work. NOTES: The embankment and subgrade shall be adjusted to conform to the lines and grades on the plans in accordance with Section 205 and 302 of the 1997 Standard State Specifications and its supplements. The upper six (6) inches of the subgrade shall be scarified, mixed and recompacted to the following compaction requirements: Percent Density Moisture Minimum Requirements Maximum 95 Min. Opt. -3% Opt. +3% Areas not meeting specified moisture density test requirements shall be removed and recompacted at the Contractor's expense. All subgrade compaction and water necessary for subgrade construction shall not be paid for directly but shall be considered subsidiary to the items of the contract. Excavation, backfilling, and sawing control joints, keyway, tie bars, dowel pins, and rubberized joint sealant shall be considered subsidiary to the unit price per square yard of pavement. CALL BEFORE YOU DIG DIGGERS HOTLINE OF NEBRASKA 1-800-331-5666 ASPHALTIC CONCRETE, TYPE 17C W/.40 CRUSHED Asphaltic Concrete, Type 17C, shall conform to the AASHTO T245 test for a 50 blow mix criteria. Subsection 1007.01 in the Standard Specifications is amended to include Asphaltic Concrete, Type 17C. The combined mineral aggregate for Asphaltic Concrete, Type 17C, shall have a minimum crushed value of 40 percent. The crushed value for mineral aggregates shall follow the Special Provision, "CRUSHED AGGREGATE FOR ASPHALTIC CONCRETE". Of the combined mineral aggregate not more than 60 percent can be limestone. The target field air void shall be 3.5 percent. The gradation of the combined aggregates shall be such that a job mix formula meeting the gradation requirements shown below can be established. RANGE FOR TARGET VALUES (112" Gradation Band "A") SIEVE SIZE PERCENT PASSING Min. Max. 1 -inch %-inch Yrinch 3/8 -inch No. 4 No. 10 No. 30 No. 50 No. 200 100 98 94 80 52 32 17 10 3 100 100 98 88 70 38 24 7 The percent design target air void shall equal the field target plus one percent. Field control target air voids shall consist of a maximum equal to the target plus one percent and a minimum equal to the target minus one percent, based on the moving average of four tests. The minimum percent voids in mineral aggregates, (VMA) shall have a lab design of ** and field control value of **. The dust/ac ratio shall have a maximum (lab design) value of 1.2 and a maximum (cold feed) value of 1.4. s$4.;�®cored DAVID L WACKER E-5090 •!�ss A\CITY OF HASTINGS, ENGINEERING DEPT. CIO Project R- 2002 Asphalt Overlay Proj. No. R-2002-1 Description Asphalt Pavement Spec. Sheet Designs/ J.L. Drown ey J.L. Dote 1/02 Contractor MP� Dm. No. 2 of 3 ASPHALTIC ALTERNATE MIX DESIGN Band) CONCRETE, TYPE17R (A 3/4 1/2 3/8 4 10 30 50 200 C.N. FM Materials 19MM 12.5MM 9.5MM 4.75MM 4MM 600M 300M 75M 3A Gravel 100 100 99 89 58 26 16 6 97 45.7 Wash Sand 100 100 100 100 99 66 66 1 0 0 2A 100 98 96 78 27 10 .3 1 0 40 RAP 100 94 87 52 34 23 19 11 90 44.7 5/8 X 4 100 50 9 5 4 3 2 2 100 44.4 100 100 100 100 100 100 100 100 0 3A Gravel 40% 40 40 39.6 35.6 23.2 10.4 6A 2.4 38.8 18.28 Wash Sand 20% 20 20 20 20 19.8 13.2 4.6 0.2 0 0 2A 0% 0 0 0 0 0 0 0 0 0 0 RAP 35% 35 32.9 30.45 18.2 11.9 8.05 6.65 3,85 31.5 15.645 518 X 4 5% 5 2.5 0.45 0.25 0.2 0.15 0.1 0.1 5 2.22 0% 0 0 0 0 0 0 0 0 0 0 Combined Gradation 100% 100 95.4 90.5 74.05 55.1 31.8 17.75 6.55 75.3 36.145 Specified Gradation +98 94+ 80-98 52-88 32-70 17-38 10-24 3-7 0 0 Actual gradation 100 94 89 80 59 29 17 7 Voids 3.6 Oil 5.31 s$4.;�®cored DAVID L WACKER E-5090 •!�ss A\CITY OF HASTINGS, ENGINEERING DEPT. CIO Project R- 2002 Asphalt Overlay Proj. No. R-2002-1 Description Asphalt Pavement Spec. Sheet Designs/ J.L. Drown ey J.L. Dote 1/02 Contractor MP� Dm. No. 2 of 3